FUJI错误代码查询.pdf - 第1436页
Display: Used by: Cause: Lead_width in Part data has not been specified. Remedy: Specify Lead_width in Part data. ------------------------------ Code: 1D138112 Display: Used by: Cause: Lead_length_x in Part data has not …
Code: 1D134003
Display:
Used by:
Cause: The part shape could not be detected.
Remedy: Check the image taken by vision processing.
------------------------------
Code: 1D134005
Display:
Used by:
Cause: The size of the part in the X direction is too large.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D134006
Display:
Used by:
Cause: The size of the part in the X direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D134007
Display:
Used by:
Cause: The size of the part in the Y direction is too large.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D134008
Display:
Used by:
Cause: The size of the part in the Y direction is too small.
Remedy: Check the part shape and the orientation of the part.
------------------------------
Code: 1D138002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large.Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D138100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D138110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D138111
第 1435 页
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D138112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D138113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D138114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D138115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D138120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D138121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D138122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D138123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
第 1436 页
Remedy: Specify Qty_3.
------------------------------
Code: 1D1382??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1383??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1384??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1385??
Display:
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1388??
Display:
Used by:
Cause: A lead on the left side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1389??
Display:
Used by:
Cause: A lead on the left side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D138A??
Display:
Used by:
Cause: A lead on the lower side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
第 1437 页