Used by: Cause: When the nozzle array is set to automatic configuration, the number of necessary nozzles exceeds the maximum number of nozzles on the revolver, 12. Remedy: There is an error in the program file. Revise th…
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 2304003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 50.
------------------------------
Code: 2304003D
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 2, the slot number input range is 1 to 450.
------------------------------
Code: 2304003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 2304003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 23040040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 50.
------------------------------
Code: 23040041
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 2, the slot number input range is 1 to 450.
------------------------------
Code: 23040042
Display: There are more than 12 kinds of Nozzles specified (Too many for the Revolver).
第 2147 页
Used by:
Cause: When the nozzle array is set to automatic configuration, the number of necessary nozzles exceeds
the maximum number of nozzles on the revolver, 12.
Remedy: There is an error in the program file. Revise the nozzle specification file, or revise the nozzle
name, minimum nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMI) and maximum nozzle diameter
(PARTS/ENVDT/XP141ENVDT-/PENMA) fields in the part data.
------------------------------
Code: 23040044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP141ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP141ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23040045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Nozzle Name (PARTS/ENVDT/XP141ENVDT-
/PENNZN) in the part data.
------------------------------
Code: 23040047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23040048
Display: Two or more first slots (reference slot) have been specified for the same alternate feeder loop. The
Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 23040049
Display: Two or more first slots (reference slots) have been specified for the same alternate feeder loop.
The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
第 2148 页
Code: 2304004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop? .
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2304004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2304004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230400A3
Display: Optimization cannot be performed if there are less than two active fiducial marks.
Used by:
Cause: Optimization cannot be performed for programs containing less than two active fiducial marks,
including skipped marks.
Remedy: Add two or more active fiducial mark sequences to the program.
------------------------------
Code: 230400A4
Display: Optimization cannot be performed because no valid placement sequences exist.
Used by:
Cause: Optimization cannot be performed because all placement sequences are skipped.
Remedy: The program must contain at least one placement sequence that is not to be skipped.
------------------------------
Code: 23040102
Display: Only 8mm and 12mm feeders can be handled by the XP-141E.
Used by:
Cause: The tape width indicated in Tape Width (PARTS/PACKLS-/TAPEWIDTH) or Packaging Name
(PARTS/HEADER/CMPNAME) is neither 8mm nor 12mm. This feeder cannot be mounted on the XP-141E.
Remedy: There is an error with the tape width specified in the part data of the program file. Correct the
error.
------------------------------
Code: 23040105
Display: Unused Nozzle(s) exist in the Revolver. Continue?
Used by:
Cause: Unused nozzle(s) exist in the revolver, or unusable nozzles are set in the revolver.
Remedy: Optimize with 乬Configure feeders automatically乭, or revise the nozzle array in the program file
or with manual input.
------------------------------