FUJI错误代码查询.pdf - 第1221页
Used by: Cause: Failed to read the nozzle offset value. Remedy: This error occurs if an attempt is made to read the nozzle offset value before the "nozzle object" has been generated. This is not a common error.…
Code: 1CFF500C
Display: 1CFF500C
Used by:
Cause: Failed to delete the "nozzle object".
Remedy: This error occurs if an "nozzle object" deletion is attempted before the "nozzle object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500D
Display: 1CFF500D
Used by:
Cause: Failed to delete the "fiducial object".
Remedy: This error occurs if an "fiducial object" deletion is attempted before the "fiducial object" has been
registered. This is not a common error. There could be a visionsystem abnormality. Restart the system.
Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500E
Display: 1CFF500E
Used by:
Cause: Failed to generate the "fiducial object".
Remedy: This error occurs if a re-registration is attempted without deleting the object, or when "part
object" generation is attempted before the "calibration object" has been registered. This is not a common
error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data and contact
Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF500F
Display: 1CFF500F
Used by:
Cause: Failed to generate the " nozzle object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5010
Display: 1CFF5010
Used by:
Cause: Failed to generate the "nozzle inspection object".
Remedy: This error occurs if a re-registration is attempted without deleting the object. This is not a
common error. There could be a visionsystem abnormality. Restart the system. Obtain the trace data
and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5011
Display: 1CFF5011
Used by:
Cause: Failed to set the nozzle offset.
Remedy: This error occurs if an attempt is made to specify the nozzle offset before the "nozzle object" has
been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5012
Display: 1CFF5012
第 1220 页
Used by:
Cause: Failed to read the nozzle offset value.
Remedy: This error occurs if an attempt is made to read the nozzle offset value before the "nozzle object"
has been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5013
Display: 1CFF5013
Used by:
Cause: Failed to read the nozzle center value.
Remedy: This error occurs if an attempt is made to read the nozzle center value before the "nozzle object"
has been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFFF001
Display: Communication Error with Vision Processor
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: Communication is not possible due to a vision processing error.
Remedy: Turn off the machine.If this error occurs often contact Fuji.
------------------------------
Code: 1CFFF003
Display: Application Error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: Error in the parameters determining the vision processing method.
Remedy: Turn off the machine.If this occurs often contact Fuji.
------------------------------
Code: 1CFFF004
Display: VP Software Version Error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: The vision processing function was not supported in the vision processing software.
Remedy: Use the up-grade version software supporting the necessary functions.
------------------------------
Code: 1CFFF006
Display: Application error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when the specified registered image does not exist.
Remedy: Turn off the machine. Reset-start the machine.If this occurs often contact Fuji.
------------------------------
Code: 1CFFF007
Display: Application error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: The specific data for the registered image is wrong.
Remedy: Turn off the machine. Restart the machine. If this occurs often contact Fuji.
------------------------------
Code: 1CFFF008
Display: Communication Error with Multiplexer.
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when communication with the multiplexer becomes impossible.
Remedy: Turn off the machine and ensure that the cables are connected to the multiplexer.
------------------------------
Code: 1CFFF009
第 1221 页
Display: No VP Board
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when checking the type of vision processing board.
Remedy: Ensure that the vison processing board is installed in the VME rack. If it exists, then check the
setting of the dip switches on the front of the vision processing board.
------------------------------
Code: 1D000001
Display:
Used by:
Cause: There is a vision processing pitch error (When MCS displayed the new version and the machine is
using the old version).
Remedy: Check the part pitch or Part data.
------------------------------
Code: 1D000002
Display:
Used by:
Cause: There is a vision processing pitch error (When MCS displayed the new version and the machine is
using the old version).
Remedy: Check the orientation of the parts on the feeder. Check Part data.
------------------------------
Code: 1D005001
Display: 影像处理系统出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 影像处理系统出错
Remedy: 是内部错误,一般不发生。如果发生时,请获取跟踪数据并与生产程序或元件数据一起送至弊社。
------------------------------
Code: 1D005002
Display: 影像处理系统出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 影像处理系统出错
Remedy: 是内部错误,一般不发生。如果发生时,请获取跟踪数据并与生产程序或元件数据一起送至弊社。
------------------------------
Code: 1D005003
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错
Remedy: 在元件数据的第1要素中记载的引脚数太少时,不能进行粗定位。请修正元件数据。
------------------------------
Code: 1D005004
Display: 图形匹配出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 由于某种原因,图形匹配失败。
Remedy: 请更换发生错误的元件或确认元件数据以及模板是否正确。
如果元件数据以及模板正确时,请调查吸取状态是否不良、影像的明亮度是否有问题、焦距是否对准以及是否摄
有污垢。
<XP24*><XP341>
多画面处理时,请确认以分割画面摄入的影像的合成是否正常地进行。
合成没有正常地进行时,请确认元件的高度和元件数据的 Part Height 是否正确、吸嘴置放地测定是否正常地
进行。
------------------------------
Code: 1D005005