FUJI错误代码查询.pdf - 第2037页

Code: 2100B206 Display: Line Descriptor read error - press [ESC] key Used by: Cause: Unable to read the line descriptor. Remedy: Check the line descriptor file. ------------------------------ Code: 2100B207 Display: can&…

100%1 / 5282
Used by:
Cause: An error occurred when creating the work file for generating the offset table.
Remedy: Re-execute the analyzer at the UCI screen. If this does not work, execute the analyzer after
completing the operation presently being executed. Alternatively, shorten the time frame being analyzed.
If this does not work, reboot the MCS.
------------------------------
Code: 2100B1CB
Display: Offset table work data file open error.
Used by:
Cause: An error occurred when the work file for generating the offset table was opened.
Remedy: Select "NO" to end the operation presently being executed. Return to the UCI screen and re-
execute the analyzer.
------------------------------
Code: 2100B1CC
Display: Offset table work data file read error.
Used by:
Cause: The work file for generating the offset table could not be read.
Remedy: Select "NO" to end the operation presently being executed. Return to the UCI screen and re-
execute the analyzer.
------------------------------
Code: 2100B1CD
Display: Offset table work data file write error.
Used by:
Cause: Data could not be written to the work file for generating the offset table.
Remedy: End the operation presently being executed, return to the UCI screen, and re-execute the
analyzer. Alternatively, shorten the time frame being analyzed. If this does not work, reboot the MCS.
------------------------------
Code: 2100B200
Display: change path error - press [ESC] key
Used by:
Cause: There was a path change error.
Remedy: Re-execute the function.
------------------------------
Code: 2100B201
Display: loglist pipe open error - press [ESC] key
Used by:
Cause: Unable to open the loglist.
Remedy: Re-execute the function. If the error recurs, reset the system.
------------------------------
Code: 2100B204
Display: can't open monitor read pipe
Used by:
Cause: Unable to open the monitor read pipe.
Remedy: Reset the system.
------------------------------
Code: 2100B205
Display: CTR event link error - press [ESC] key
Used by:
Cause: Unable to link the CRT event.
Remedy: Re-execute the function. If the error recurs, reset the system.
------------------------------
第 2036 页
Code: 2100B206
Display: Line Descriptor read error - press [ESC] key
Used by:
Cause: Unable to read the line descriptor.
Remedy: Check the line descriptor file.
------------------------------
Code: 2100B207
Display: can't create setting file
Used by:
Cause: Unable to create the setting file.
Remedy: Re-execute the function from the UCI menu.
------------------------------
Code: 2100B208
Display: can't save setting data
Used by:
Cause: Unable to save the setting file.
Remedy: Re-execute the function.
------------------------------
Code: 2100B209
Display: Can't set loglist start time to the future
Used by:
Cause: The loglist start time is set to the future.
Remedy: Set the correct time and date.
------------------------------
Code: 2100B20A
Display: Can't set loglist end time prior to the start time
Used by:
Cause: The loglist start time is set prior to the end time.
Remedy: Set a correct time and date.
------------------------------
Code: 2100B20B
Display: Line name not found in Line Descriptor
Used by:
Cause: The line name was not found in the line descriptor.
Remedy: Input the line name into the line descriptor.
------------------------------
Code: 2100B20C
Display: Machine nickname not found in specified line
Used by:
Cause: The machine nickname was not found in the line descriptor.
Remedy: Input the machine nickname into the line descriptor.
------------------------------
Code: 2100B20D
Display: Machine nickname not found in specified line
Used by:
Cause: The machine nickname was not found in the line descriptor.
Remedy: Input the machine nickname in the line descriptor.
------------------------------
Code: 2100B20E
Display: Program name not found
Used by:
第 2037 页
Cause: The program name was not found.
Remedy: Input the correct program name.
------------------------------
Code: 2100B20F
Display: Reverse start time and end time
Used by:
Cause: The start times and end times have been entered in reverse order.
Remedy: Input the times correctly.
------------------------------
Code: 2100B210
Display: Undefined evaluation filename
Used by:
Cause: The evaluation file has not been specified.
Remedy: Input an output filename for the evaluation file.
------------------------------
Code: 2100B211
Display: Undefined line name
Used by:
Cause: The line name has not been specified.
Remedy: Input the line name.
------------------------------
Code: 2100B212
Display: Undefined machine nickname
Used by:
Cause: The machine nickname has not been specified.
Remedy: Input the machine nickname.
------------------------------
Code: 2100B213
Display: Undefined analyze start or end time
Used by:
Cause: Either the start or end time has not been specified.
Remedy: Input the start or end time.
------------------------------
Code: 2100B214
Display: Undefined program name
Used by:
Cause: The production program name has not been specified.
Remedy: Input the production program name.
------------------------------
Code: 2100B215
Display: Can't print evaluation file to terminal
Used by:
Cause: Unable to create an evaluation file.
Remedy: Re-execute the function.
------------------------------
Code: 2100B216
Display: Loglist initilize error
Used by:
Cause: A loglist error occurred during initialization.
Remedy: Re-execute the function.
------------------------------
第 2038 页