FUJI错误代码查询.pdf - 第2011页
Display: Machine type mismatch Used by: Cause: The wrong type of machine has been chosen. Remedy: Choose the correct machine. Check that the transmission file (Program, Proper) machine type and the machine are the same. …
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A313
Display: !?:A313 Wait file full
Used by:
Cause: The transfer buffer is full.
Remedy: Halt transmission until the buffer empties again.
------------------------------
Code: 2100A314
Display: pck fork error
Used by:
Cause: The data check function could not be started
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A315
Display: Justify error
Used by:
Cause: A problem exists with the data check function.
Remedy: Re-select the program.
------------------------------
Code: 2100A316
Display: not change program
Used by:
Cause: A program named "0" was specified, so program change could not be carried out.
Remedy: Specify a program other than "0".
------------------------------
Code: 2100A317
Display: NO MC actvei
Used by:
Cause: The machine cannot transmit.
Remedy: Check that the machine is on. This message is not currently in use.
------------------------------
Code: 2100A318
Display: NO procedur file
Used by:
Cause: The procedure file has not been specified, or the wrong line has been specified.
Remedy: Check the line, and/or specify the procedure file.
------------------------------
Code: 2100A319
Display: NO select line name
Used by:
Cause: An incorrect line name was chosen.
Remedy: Specify the correct line name.
------------------------------
Code: 2100A31A
Display: NOW WAITING
Used by:
Cause: The machine is now communicating and your command is being processed.
Remedy: Wait for the machine to finish.
------------------------------
Code: 2100A31B
第 2010 页
Display: Machine type mismatch
Used by:
Cause: The wrong type of machine has been chosen.
Remedy: Choose the correct machine. Check that the transmission file (Program, Proper) machine type
and the machine are the same.
------------------------------
Code: 2100A31C
Display: /pipe/Wmc busy error
Used by:
Cause: The machine is busy.
Remedy: Wait for the machine to finish. If the previous communication is finished and this error still
occurs, re-boot MCS.
------------------------------
Code: 2100A31D
Display: event error
Used by:
Cause: The terminal event was incorrectly linked.
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A31E
Display: m2_nick_check() open error
Used by:
Cause: The environment variable Nickname_check value cannot be taken.
Remedy: Re-execute the function. If the error still occurs, re-install the system.
------------------------------
Code: 2100A31F
Display: NO rewrite (-r)
Used by:
Cause: During HOST start-up the overwrite option could not be set.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A320
Display: Option switch error
Used by:
Cause: During HOST start-up the option was not set properly.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A321
Display: tci tran format error
Used by:
Cause: When the tci tran command was executed at the host, there was a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A322
Display: tci mlist format error
Used by:
Cause: When the tci mlist command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A323
Display: tci mdel format error
第 2011 页
Used by:
Cause: When the tci mdel command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A324
Display: tci mmv format error
Used by:
Cause: When the tci mmv command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A325
Display: tci ptran format error
Used by:
Cause: When the tci ptran command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A326
Display: tci prcv format error
Used by:
Cause: When the tci prcv command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A327
Display: tci stran format error
Used by:
Cause: When the tci stran command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100A328
Display: tci plt format error
Used by:
Cause: When the tci plt command was executed at HOST, there is a format error.
Remedy: Check the HOST start-up format.
------------------------------
Code: 2100B100
Display: Listing file create error
Used by:
Cause: The listing file could not be created.
Remedy: Shorten the listing time setting range.
------------------------------
Code: 2100B101
Display: Listing file open error
Used by:
Cause: The listing file could not be opened.
Remedy: Return to the UCI and re-execute the function.
------------------------------
Code: 2100B102
Display: Listing file read error
Used by:
Cause: The listing file could not be read.
Remedy: Return to the UCI menu and re-execute the function.