FUJI错误代码查询.pdf - 第1527页

Part data. Remedy: Set a value for the "Body_size 1" parameter. ------------------------------ Code: 1D1E8115 Display: Same as code Used by: Cause: No value has been set for the "Body_size 0" paramete…

100%1 / 5282
Code: 1D1E0014
Display: Same as code.
Used by:
Cause: The lead quantity is set to 2, but 3 leads were found.
Remedy: Check the part's shape. Check the part supply direction. Check the Part data and the Device
data.
------------------------------
Code: 1D1E8002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D1E8100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D1E8110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D1E8111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D1E8112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D1E8113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D1E8114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
第 1526 页
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D1E8115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D1E8120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D1E8121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D1E8122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D1E8123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.
Remedy: Set a value for the "Qty 3" parameter.
------------------------------
Code: 1D1E82??
Display: Same as code.
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E83??
Display: Same as code.
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E84??
第 1527 页
Display: Same as code.
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E85??
Display: Same as code.
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E88??
Display: Same as code.
Used by:
Cause: A lead on the left side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E89??
Display: Same as code.
Used by:
Cause: A lead on the left side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E8A??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E8B??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E8C??
Display: Same as code.
Used by:
Cause: A lead on the right side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E8D??
Display: Same as code.
Used by:
Cause: A lead on the right side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D1E8E??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too long. (The last two digits of the code indicate the lead number.)
第 1528 页