Cause: The lead pitch on the left side is too narrow. (The last two digits of the code indicate the lead number.) Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. -------…
Display: Same as code.
Used by:
Cause: A lead on the left side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308A??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308B??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308C??
Display: Same as code.
Used by:
Cause: A lead on the right side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308D??
Display: Same as code.
Used by:
Cause: A lead on the right side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308E??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D308F??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3090??
Display: Same as code.
Used by:
Cause: The lead pitch on the left side is too wide. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3091??
Display: Same as code.
Used by:
第 1634 页
Cause: The lead pitch on the left side is too narrow. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3092??
Display: Same as code.
Used by:
Cause: The lead pitch on the lower side is too wide. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3093??
Display: Same as code.
Used by:
Cause: The lead pitch on the lower side is too narrow. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3094??
Display: Same as code.
Used by:
Cause: The lead pitch on the right side is too wide. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3095??
Display: Same as code.
Used by:
Cause: The lead pitch on the right side is too narrow. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3096??
Display: Same as code.
Used by:
Cause: The lead pitch on the upper side is too wide. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3097??
Display: Same as code.
Used by:
Cause: The lead pitch on the upper side is too narrow. (The last two digits of the code indicate the lead
number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A0??
Display: Same as code.
Used by:
Cause: A lead on the left side is too wide. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
第 1635 页
------------------------------
Code: 1D30A1??
Display: Same as code.
Used by:
Cause: A lead on the left side is too narrow. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A2??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too wide. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A3??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too narrow. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A4??
Display: Same as code.
Used by:
Cause: A lead on the right side is too wide. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A5??
Display: Same as code.
Used by:
Cause: A lead on the right side is too narrow. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A6??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too wide. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30A7??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too narrow. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30B0??
Display: Same as code.
Used by:
Cause: A lead that should not exist has been found on the left side. (The last two digits of the code
indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D30B1??