FUJI错误代码查询.pdf - 第510页
------------------------------ Code: 12050304 Display: "Servo alarm: X-axis overtravel" (CP4,CP6) "Servo alarm: Y-axis overtravel" (CP43) Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP64…
------------------------------
Code: 1205020B
Display: 搅拌风扇警告
Used by: GPX,NXTP
Cause: 搅拌风扇异常。这样的话,因无法搅拌,系统有可能过热死机。
Remedy: 请更换搅拌风扇的马达。
<img src="$LKEY_ERRIMG_MC$/1205020B.PNG">
------------------------------
Code: 1205020C
Display: 逆变器异常
Used by: NXTP
Cause: [真空泵单元] 逆变器发生异常。
Remedy: 为了重新启动逆变器,请重新启动机器。
即使重新启动也不能解除异常时,请更换逆变器。
<img src="$LKEY_ERRIMG_MC$/1205020C.PNG">
------------------------------
Code: 1205020D
Display: 电路板真空泵逆变器异常
Used by: NXTP,GPX,GPX-C
Cause: [真空泵单元] 电路板真空泵的逆变器发生异常。
Remedy: 为了重新启动逆变器,请重新启动机器。
即使重新启动也不能解除异常时,请更换逆变器。若机器不对应电路板真空泵单元则无法使用真空夹紧功能。请将设定
变更为不使用真空夹紧。
<img src="$LKEY_ERRIMG_MC$/1205020D.PNG">
------------------------------
Code: 1205020E
Display: 钢板真空压力低下
Used by: NXTP
Cause: 版对准时检测到钢板真空漏气。
Remedy: 请确认钢板和主平台的结合面是否存在异物。
<img src="$LKEY_ERRIMG_MC$/1205020E.PNG">
------------------------------
Code: 12050301
Display: Overtravel NG ?? (IP, IP2, GL, GSP) CHECK ?-OT (FCP)
Used by: CP3,GL2,GL5,GL541,GSP2,GSP3,GSP5,IP1,IP2,IP3,GPX-C
Cause: The overtravel sensor indicated by ? has been activated.
Remedy: Move the axis out of the overtravel area, either manually or through inching.
------------------------------
Code: 12050302
Display: "Overtravel [-|+][X |Y |S |Z |SSD ]" "Servo alarm: D-axis overtravel" (CP4)
Used by: CP4-1,CP4-2,GSP5,GP2,GP3,GP551,GP6,NP132,NP133
Cause: The axis named in the display has overtraveled in the indicated direction. The D-axis has
overtraveled.(CP4)
Remedy: Move the indicated axis either by inching or manually to cancel the overtravel. Inch the D-axis to
cancel the overtravel.(CP4)
------------------------------
Code: 12050303
Display: "Servo alarm: X-axis overtravel" (CP43)
Used by: CP4-3
Cause: The X-axis has overtraveled.
Remedy: Inch the X-axis to cancel the overtravel.
第 509 页
------------------------------
Code: 12050304
Display: "Servo alarm: X-axis overtravel" (CP4,CP6) "Servo alarm: Y-axis overtravel" (CP43)
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP5
Cause: The X-axis has overtraveled. The Y-axis has overtraveled.(CP43)
Remedy: Inch the X-axis to cancel the overtravel. Inch the Y-axis to cancel the overtravel.(CP43)
------------------------------
Code: 12050305
Display: "Servo alarm: Y-axis overtravel" (CP4,CP6) "Servo alarm: Z-axis overtravel" (CP43)
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP5
Cause: The Y-axis has overtraveled. The Z-axis has overtraveled.(CP43)
Remedy: Inch the Y-axis to cancel the overtravel. Inch the Z-axis to cancel the overtravel.(CP43)
------------------------------
Code: 12050306
Display: "Servo alarm: Z-axis overtravel" (CP4,CP6) "Servo alarm: D1-axis overtravel" (CP43)
Used by: CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP5
Cause: The Z-axis has overtraveled. The D1-axis has overtraveled.(CP43)
Remedy: Inch the Z-axis to cancel the overtravel. Inch the D1-axis to cancel the overtravel.(CP43)
------------------------------
Code: 12050307
Display: "Servo alarm: D1-axis overtravel" (CP4,CP6) "Servo alarm: D2-axis overtravel" (CP43) "Servo
alarm: DF-axis overtravel" (CP652C)
Used by: CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP5
Cause: The D1-axis has overtraveled. The D2-axis has overtraveled.(CP43) The DF-axis has
overtraveled.(CP652C)
Remedy: Inch the D1-axis to cancel the overtravel.Inch the D2-axis to cancel the overtravel.(CP43) Inch
the DF-axis to cancel the overtravel.(CP652C)
------------------------------
Code: 12050308
Display: "Servo alarm: D2-axis overtravel" (CP6) "Servo alarm: DR-axis overtravel" (CP652C)
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The D2-axis has overtraveled. The DR-axis has overtraveled.(CP652C)
Remedy: Inch the D2-axis to cancel the overtravel. Inch the DR-axis to cancel the overtravel.(CP652C)
------------------------------
Code: 12050309
Display: Servo error SS-axis:Over travel
Used by: QP132
Cause: The SS-axis is in overtravel.
Remedy: Correct the position of the SS-axis using the inching keys.
------------------------------
Code: 1205030A
Display: Servo error MX-axis:Over travel
Used by: QP132
Cause: The MX-axis is in overtravel.
Remedy: Correct the position of the MX-axis using the inching keys.
------------------------------
Code: 1205030B
Display: Servo error MY-axis:Over travel
Used by: QP132
Cause: The MY-axis is in overtravel.
Remedy: Correct the position of the MY-axis using the inching keys.
第 510 页
------------------------------
Code: 1205030C
Display: Servo error PO-axis:Over travel
Used by: QP132
Cause: The PO-axis is in overtravel.
Remedy: Correct the position of the PO-axis using the inching keys.
------------------------------
Code: 1205030D
Display: Y-axis collision!
Used by: NP2,QP3
Cause: The Y-axis collision sensor has been triggered. There is interference between the Y1 and Y2
axis.(NP2,QP3)
Remedy: Use the inching keys to clear the interference.(NP2,QP3)
------------------------------
Code: 1205030E
Display: 往复臂 O.T.异常
Used by: NXTP
Cause: 往复臂的移动目标值为范围外,从属搬运轨道越过超程传感器。
Remedy: 请向前侧移动,解除传感器。
<img src="$LKEY_ERRIMG_MC$/1205030E.PNG">
------------------------------
Code: 1205031?
Display: Servo Ararm ? axis. Overtravel. (CP6)
Used by:
Cause: Overtravel error at the ? axis.
Remedy: Use inching to clear the overtravel condition.
------------------------------
Code: 12050311
Display: 伺服报错 超程
Used by: GPX-C
Cause: 显示位置上发生超程现象。
Remedy: 请使用微操作或手操作解除超程现象。
------------------------------
Code: 12050401
Display: 内存备份不良 Memory Backup NG (IP,IP2,GSP)
Used by: GPX,IP, IP2, GSP,NXTP
Cause: 有效的Proper和Status没有被传输。
Remedy: 请传输Proper和Status。此时,在传输Proper和Status后,暂时关闭电源然后重新接通。 (有可能伺服的
动作不正常)在每次接通电源后发生时,请检查备份用的电池。进行了复位后也会显示该错误。
<img src="$LKEY_ERRIMG_MC$/12050401.PNG">
------------------------------
Code: 12050402
Display: "Data Transmission Line NG" (IP, GL), "Transmiterr" (CP3)
Used by: GL2
Cause: The machine cannot transmit data to the MCS-16. The memory buffer has become full due to a
failure in communication with the MCS-16.
Remedy: Check the communication cable. Make sure the MCS-16 is not hung up.
------------------------------
Code: 12050403
Display: MFU1 (2) is not ready
Used by: IP2
第 511 页