Used by: IP1,IP2,IP3 Cause: Even though the nozzle has not been removed from the station, the nozzle check sensor is not on. Alternately, the sensor is on for a position in which there is a nozzle in machine memory. When…

100%1 / 5282
Tray drawer not set IP2
Used by: IP1
Cause: The tray drawer is open.
Remedy: Either the left or right tray set sensor is on. Close the tray drawers by hand.
------------------------------
Code: 12062008
Display: No Nozzle(IP,IP2)
Nozzle selection error!(NP2,QP3)
Used by: IP1,IP2,NP2,QP3
Cause: There is no nozzle in the position from which nozzle change is to be carried out (IP, IP2).
The required nozzle is not present in the nozzle station.(NP2,QP3)
Remedy: Set a nozzle in that position. Alternately, check the sensor sensitivity level.
Check the production program and nozzle memory.(NP2,QP3)
------------------------------
Code: 12062009
Display: Error: Duplex Nozzle
Used by: IP1,IP2
Cause: The operator has attempted to eject the nozzle, but there is already a nozzle at the place where
the nozzle was to have been ejected (IP, IP2).
Remedy: When the machine memory does not match actual conditions, either change the nozzle by hand
or perform a nozzle check. When there is no nozzle in the position in question, adjust the sensor.
------------------------------
Code: 1206200A
Display:
Used by: IP1
Cause: Not in use. The original 1206200A message has been moved to 1206200C.
Remedy: None.
------------------------------
Code: 1206200B
Display: Check Nozzle
Used by: IP2
Cause: When performing zero setting, the nozzle in the machine memory has been placed onto the block
(IP). Both the L and LL nozzles are not at their nozzle stations, and after nozzle check the nozzle cannot
be cancelled (IP2).
Remedy: Check the sensors at the nozzle stations. If the nozzle has not been picked, perform a nozzle
check (IP). Place the nozzles at the nozzle station (IP2).
------------------------------
Code: 1206200C
Display: NOZZLE SIZE CHECK ERROR
Used by: IP1
Cause: During nozzle check an irrelevant nozzle has been indicated.
Remedy: Adjust the sensor, and perform nozzle check.
------------------------------
Code: 1206200D
Display: NOZZLE CHECK ERROR
Used by: IP1,IP3
Cause: An error occurs in the middle of nozzle check.
Remedy: Perform nozzle check again.
------------------------------
Code: 1206200E
Display: Nozzle Change error
第 608 页
Used by: IP1,IP2,IP3
Cause: Even though the nozzle has not been removed from the station, the nozzle check sensor is not on.
Alternately, the sensor is on for a position in which there is a nozzle in machine memory. When changing
nozzles, the target nozzle is not at the nozzle station.
Remedy: Adjust the sensitivity of the LLN_ORIGIN, LN_ORIGIN, MN_ORIGIN and _SN_ORIGIN sensors.
Alternately, the correct clamp was not used. Check the clamp. Check whether all the nozzles specified in
the production program are all there, and check that the nozzles specified in the program are correct.
------------------------------
Code: 1206200F
Display: Move Nozzle to original point
Used by: IP1
Cause: According to the machine memory a nozzle has not been picked up, but the nozzles are not all
back in their original positions. Alternately, the nozzle has been picked in machine memory but is in
reality not picked up.
Remedy: Remove the nozzle by hand, so that the reality is the same as indicated in the STATUS heading
in the 1st display area. Alternately, press the [NOZZLE COMMAND] function key. To remove the nozzle,
put the I/O setting CHUCK_RELEASE to on, and the nozzle can be removed. Take care not to drop the
nozzle when removing it by hand. To place the nozzle back into its original position, set the I/O setting
NOZZLE_SHUTTER to ON to open the shutters, and OFF to close them.
------------------------------
Code: 12062010
Display: CHECK LOADER
Used by:
Cause: When the Y axis can be inched, and the conveyor notch, loader stopper or reference pin is on,
there is a problem with inching.
Remedy: Turn off the above switches at the I/O board. Except for Y axis inching, this error does not
affect normal operation.
------------------------------
Code: 12062011
Display: Nozzle Shift
Used by: IP1
Cause: During nozzle change, the Y axis nozzle shift detection sensor (left edge or right edge) has been
removed.
Remedy: Check the nozzle left/right edge sensor.
------------------------------
Code: 12062012
Display: CHECK Z
Used by: IP1,IP3
Cause: The Z axis is less than 5 mm over the upper surface of the board (Z0). This could cause
interference in the Y and other axes, so inching cannot be carried out.
Remedy: Inch the Z axis up.
------------------------------
Code: 12062013
Display: CHECK NOZZLE STATION
Used by:
Cause: The nozzle station has shifted to the right. This interferes with Y axis movement, so inching
cannot be carried out.
Remedy: Return the nozzle station to the left. This error applies only to the IP1 shift station.
------------------------------
Code: 12062014
Display: CHECK NOZZLE POSITION
第 609 页
Used by: IP1,IP3
Cause: The results of nozzle check indicate that the nozzle which was picked up when the machine
operation was cancelled is still in the nozzle station.
Remedy: Check the nozzle station.
------------------------------
Code: 12062015
Display: CHECK FEEDER STATION 1(2)
Used by: IP1
Cause: The feeder parts shuttle is advanced.
Remedy: This is interfering with the nozzle so retract the shuttle at the I/O board. For example, if the
feeder at device 20 is advanced, set the OUT 3-20 PARTS_FEEDER20 I/O setting to off. When the display
is 1, this refers to station 1, and if the display is 2, this refers to station 2.
------------------------------
Code: 12062016
Display: 200V NG
Used by:
Cause: When the start button was pressed to start zero setting, the 200V power supply was not on and
zero setting was not carried out.
Remedy: Check the thermals, circuit protectors, etc. to find the reason the power supply is not on.
------------------------------
Code: 12062017
Display: MAIN CONVEYOR POSITION ERROR
Used by: IP1
Cause: The Y table has moved away from its loading position, so the board cannot be loaded or cleared
off. This error occurs after inching, or after an emergency stop, etc.
Remedy: Inch the Y axis to return the table, or use the [LOADER], [PCBSET] or [CLROFF] command
function keys.
------------------------------
Code: 12062018
Display: Please check I/O NOZZLE STATION
Used by:
Cause: Neither of the nozzle station location sensors are on.
Remedy: Adjust either IN2-27 NOZZLE_R_END or IN2-26 NOZZLE_L_END.
------------------------------
Code: 12062019
Display: CHECK PCB SENSOR
Used by:
Cause: The board arrival sensor or the board deceleration sensor is off. Either the sensor is not adjusted
properly, or the sensor is off because of parts or holes on the board.
Remedy: Inspect the board arrival sensor or the board deceleration sensor. If this error occurs due to
parts or holes in the board, continue production.
------------------------------
Code: 1206201A
Display: Please check I/O
Used by:
Cause: On IP machines where the nozzle station shifts, neither the I/O NOZZLE_R_END nor
NOZZLE_L_END setting is on. On IP machines where the nozzle station does not shift, either the I/O
NOZZLE_R_END or NOZZLE_L_END setting is on.
Remedy: On shift style IP machines, one of them should be on, and on non-shift style machines, they
should both be off.
------------------------------