Cause: The amount of offset in the Y direction between the body center and the nozzle center specified in the part data item, "Pickup_x" in "Tolerance_information" has been exceeded. Remedy: Check the…
number of times specified. D** indicates the device number.
Remedy: Check the feeder.
------------------------------
Code: 12040404
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP65,CP642,CP643
Cause: The results of component vision processing indicate a compensation amount exceeding [p/m]30
mm ([p/m]3 mm for the CP6) in the X direction.
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.
------------------------------
Code: 12040405
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP652C,CP642,CP643
Cause: The results of component vision processing indicate a compensation amount exceeding 30 mm
([p/m]3 mm for the CP6) in the Y direction.
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.
------------------------------
Code: 12040406
Display: Same as code (CP6)
Used by: CP4-1,CP4-2,CP4-3,CP652C,CP642,CP643
Cause: An abnormality in communication with the vision processor has occurred during vision
processing.
Remedy: Turn off the machine, then restart it. Contact Fuji if this error occurs frequently.
------------------------------
Code: 12040407
Display: Same as code
Used by: CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The results of component vision processing indicate a compensation amount exceeding 30 mm in
the Q direction.
Remedy: Check the manner in which the component is picked up, and make sure that the device offset
value is appropriate.
------------------------------
Code: 12040408
Display: Same as code
Used by: IP1
Cause: In the case of a tape feeder on the IP1, a subrobot nozzle pickup error has occurred. The
subrobot nozzle has failed to pick up a component.
Remedy: Have the machine try to pick up the component again. Inspect the tape feeder.
------------------------------
Code: 12040409
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,NP132,NP133
Cause: The amount of offset in the X direction between the body center and the nozzle center specified in
the part data item, "Pickup_x" in "Tolerance_information" has been exceeded.
Remedy: Check the way the part is picked up or check the validity of the device offset value.
------------------------------
Code: 1204040A
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,NP132,NP133
第 471 页
Cause: The amount of offset in the Y direction between the body center and the nozzle center specified in
the part data item, "Pickup_x" in "Tolerance_information" has been exceeded.
Remedy: Check the way the part is picked up.
------------------------------
Code: 1204040B
Display: Same as code
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,NP132,NP133
Cause: The amount of offset in the Q direction between the body center and the nozzle center specified in
the part data item, "Pickup_x" in "Tolerance_information" has been exceeded.
Remedy: Check the way the part is picked up.
------------------------------
Code: 1204040C
Display: Feeder Indexing Error
Used by: CP-8Series
Cause: Unable to pick-up the part due to a feeder indexing error.
Remedy: Adjust the indexing pitch.
If the indexing pitch is correct, there may be a problem with the nozzle.
The nozzle may be bent not allowing the NY-axis to correct within the movable range, or the nozzle
bend has changed since last measurement and has not been compensated.
Recheck the nozzle bend and replace any excessively bent nozzles.
------------------------------
Code: 12040410
Display: Tombstoning condition detected.
Used by: CP-742ME, CP-742E, CP-752E
Cause: The detected part height is different from the height specified in Part data.
Remedy: Check to see if the part has been picked up properly. A tombstoning pickup condition may also
have occurred.
------------------------------
Code: 12040411
Display: 吸取位置公差错误
Used by: XP142,XP242
Cause: 元件的中心位置相对于吸嘴中心的偏移量超过公差值。
Remedy: 请检查元件的吸取状态以及供料器的状态。
没有发生吸取位置偏移时请执行以下的指令,重新测定吸嘴的中心位置。
·[生产]-[吸嘴编辑]-[尺寸检查]指令
·或者 XP-142E 的[生产]-[测定吸嘴中心]-[测定吸嘴中心开始]指令
------------------------------
Code: 12040412
Display: 吸取角度公差错误
Used by: XP142,XP242
Cause: 旋转方向的偏移量超过公差值。
Remedy: 请检查元件的吸取状态以及供料器的状态。
------------------------------
Code: 12040413
Display: 吸取了元件的反面。
Used by: XP142,XP242
Cause: 吸取了元件的反面。
Remedy: 请确认是否吸取了元件的反面。
吸取了元件的反面时,吸取状态有可能变坏。
请调查吸取高度、吸取位置、供料器的状态是否变坏。
请进行吸嘴中心的重新测定。
第 472 页
正常吸取的时候、请调查影像的明亮度是否有问题、元件的中央附近是否因为有污垢而没有摄入。
元件的中央附近比较暗的元件、有可能使功能产生错误动作。请将功能处于无效。
------------------------------
Code: 12040414
Display: 倾斜地将元件吸取了。
Used by: XP142,XP242
Cause: 倾斜地将元件吸取了。
Remedy: 请确认是否倾斜地将元件吸取了。
倾斜地吸取时,有可能使吸取状态变得恶劣。
请调查吸取高度、吸取位置、供料器的状态是否变得恶劣。
请进行吸嘴中心位置的重新测定。
正常地吸取时,对于形状歪斜的元件,功能有误动作的可能性。请使功能无效。
------------------------------
Code: 12040416
Display: Flux supply warning
Used by: QP3
Cause: The fixed flux unit is low on flux.
Remedy: Supply flux to the fixed flux unit.
------------------------------
Code: 12040417
Display: Tray pick-up position error
Used by: QP3
Cause: A part was found in the slot before the specified pick-up position.
Remedy: Reenter the pick-up position. If this error occurred even though a part does not exist,
a processing error may have occurred because the nozzle is bent.
Change the nozzle or disable this function.
------------------------------
Code: 12040418
Display: Tray pick-up position memory error
Used by: QP3
Cause: An attempt was made to return the part to the tray pick-up position, but the vacuum was OFF.
Remedy: The specified pick-up position has not been checked.
If the tray pick-up position is not clear, reset the pick-up position.
------------------------------
Code: 12040502
Display: Part placement confirmation error!
Used by: QP3
Cause: Failed to place the part.
Remedy: Check the nozzle and the action of the part placement confirmation sensor.
------------------------------
Code: 12040503
Display: Insertion error
Used by: QP3OF
Cause: Could not complete insertion of the positioning pins.
Remedy: Check that the positioning pins are not bent.
------------------------------
Code: 12040504
Display: Reserve
Used by: QP3
Cause: Reserve
Remedy: Reserve
第 473 页