Cause: Calibration was already being carried out. Remedy: If this error occurs often, contact Fuji. ------------------------------ Code: 1C410004 Display: Used by: Cause: A logical error occurred. This error code may occ…

100%1 / 5282
Cause: The camera Proper data has not been set. Camera Proper data has not undergone training. A
section of the mark training data has been overwritten. Use the SAVE command to make a copy of the
hard disk and use this to see whether there has been corrupted data.
Remedy: Re-measure the camera Proper data. Change the data which is different at the terminal. If
booting up from the ROM card, the part of the system which is overwritten will not start.
------------------------------
Code: 1C310011
Display:
Used by:
Cause: During calibration, a contradiction occurred. There is a contradiction with the Proper data being
used. When there are many programs in the machine, and these programs use different nozzle sizes or
cameras but the Part data files bear the same name, these file GDDUs are downloaded and saved. When
using the relevant device description, the machine will only use the last file downloaded. Therefore, when
production starts, the wide field camera is being used when the data calls for a narrow field camera, or
vice versa, and this error occurs. Alternately, if the nozzle sizes differ, error 1C410011 occurs.
Remedy: This error generally does not occur. Delete all programs from the machine and transmit only
that program which is needed.
------------------------------
Code: 1C310013
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310015
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310016
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310017
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310018
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310019
Display:
Used by:
第 1176 页
Cause: Calibration was already being carried out.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C410004
Display:
Used by:
Cause: A logical error occurred. This error code may occur during device training or inspection.
Remedy: If this error occurs often, contact Fuji and be prepared to give as many details as possible.
------------------------------
Code: 1C410100
Display:
Used by:
Cause: There is no element. There is no description of the element in the device description. This error
may occur during device training.
Remedy: Check the device description. Enter a correct element description.
When using GDG, check the contents of Part data.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
PD. lead_width
PD. lead_quality_0_3
PD. lead_information
------------------------------
Code: 1C410101
Display:
Used by:
Cause: Device segments have no edges that can be inspected. This error may occur during device
training.
Remedy: Check the device description. Enter a correct edge description.
When using e1-e4 polarity GDG, check the contents of Part data.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
PD. lead_width
PD. lead_information
------------------------------
Code: 1C410102
Display:
Used by:
Cause: There is a mistake in the segment ID.
Remedy: Check the segment ID in the device description. Enter a correct segment ID description. When
using GDG, check the contents of of Part data.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
第 1177 页
PD. lead_width
PD. lead_quality_0_3
PD. lead_information
------------------------------
Code: 1C410103
Display:
Used by:
Cause: The placement flag has not been set. This error may occur during device training.
Remedy: Check the device description placement flag. Enter a correct placement flag. This value is
generally set at 15.
------------------------------
Code: 1C410104
Display:
Used by:
Cause: There are too many pickup errors. Either the lead tip edge or the body edge is not perpendicular
to both lead side edges. This error can occur during device inspection.
Remedy: Set smaller tolerance settings (total tolerance x, total tolerance y, rotation tolerance) at the
device description. The lead edge and body edge must have a tolerance of within 90 deg +-7 deg.. Check
the part shape. For parts such as 1608 parts, if the nozzle protrudes from the corner of the part, this
error can also occur.
------------------------------
Code: 1C410105
Display:
Used by:
Cause: The coarse edge is inappropriate.
Remedy: Check the device description's coarse edge.
Enter a correct coarse edge.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
PD. lead_width
PD. lead_quality_0_3
PD. lead_information
------------------------------
Code: 1C410106
Display:
Used by:
Cause: The nozzle being used is larger than the nozzle size entered. When there are many programs in
the machine, and these programs use different nozzle sizes or cameras but the Part data files bear the
same name, these file GDDU are downloaded and saved. When using the relevant device description, the
machine will only use the last file downloaded. Therefore, when production starts, the wide field camera is
being used when the data calls for a narrow field camera, or vice versa, and error 1C31011 occurs.
Alternately, if the nozzle sizes differ, error 1C410006 occurs.
Remedy: Choose a smaller nozzle size. Check the following nozzle sizes in Part data: If the camera,
nozzle size or backlight size was changed, create a new Part data file with a different name.
PD Nozzle_size_CP4
PD Nozzle_size_Max
------------------------------
Code: 1C410107
第 1178 页