FUJI错误代码查询.pdf - 第189页
Cause: There is no free flag in __unit_admin. Remedy: None. ------------------------------ Code: 11060230 Display: Used by: Cause: There was transmission outside bvc specifications. Remedy: None. ------------------------…
Code: 1106012D
Display:
Used by:
Cause: The previous message remains at level 1 and a new message has been transmitted.
Remedy: None.
------------------------------
Code: 1106012E
Display:
Used by:
Cause: The previous message remains at level 2 and a new message has been transmitted.
Remedy: None.
------------------------------
Code: 1106012F
Display:
Used by:
Cause: The message was transmitted to the wrong level.
Remedy: None.
------------------------------
Code: 110601F5
Display:
Used by:
Cause: PM was sent previously.
Remedy: None.
------------------------------
Code: 110601F6
Display:
Used by:
Cause: An incorrect ID was used for PI.
Remedy: None.
------------------------------
Code: 110601F7
Display:
Used by:
Cause: The previous free flag was erased at PI transmission.
Remedy: None.
------------------------------
Code: 110601FE
Display:
Used by:
Cause: The PM module cannot be transmitted because it is masked.
Remedy: None.
------------------------------
Code: 110601FF
Display:
Used by:
Cause: There is an error in PM "D".
Remedy: None.
------------------------------
Code: 11060200
Display: 11060200
Used by:
第 188 页
Cause: There is no free flag in __unit_admin.
Remedy: None.
------------------------------
Code: 11060230
Display:
Used by:
Cause: There was transmission outside bvc specifications.
Remedy: None.
------------------------------
Code: 11060231
Display:
Used by:
Cause: Block skip data was sent before bT.
Remedy: None.
------------------------------
Code: 11060232
Display:
Used by:
Cause: bVZ was received even though bVP was not received.
Remedy: None.
------------------------------
Code: 11060401
Display:
Used by:
Cause: During partial transmission, new element data was not sent.
Remedy: Delete the program in the machine and retransmit that program.
------------------------------
Code: 11060402
Display:
Used by:
Cause: During partial transmission, the element data size was different from the previous size.
Remedy: Delete the program in the machine and retransmit that program.
------------------------------
Code: 11060403
Display:
Used by:
Cause: Data was sent even though the element name has not been sent.
Remedy: None.
------------------------------
Code: 11060404
Display:
Used by:
Cause: Element data's processing table was damaged.
Remedy: Reset-start the machine.
------------------------------
Code: 11060405
Display:
Used by:
Cause: An unusable command was sent.
Remedy: Reset-start the machine.
------------------------------
第 189 页
Code: 11060406
Display:
Used by:
Cause: During partial transmission, device data was added.
Remedy: Delete the program in the machine and retransmit that program.
------------------------------
Code: 11060407
Display:
Used by:
Cause: During partial transmission, tray data was added.
Remedy: Delete the program in the machine and retransmit that program.
------------------------------
Code: 11060408
Display:
Used by:
Cause: Tray data was sent even though tray data is not registered.
Remedy: Check the transmission cable. There is the possibility of ghost characters being sent.
------------------------------
Code: 11060409
Display:
Used by:
Cause: Device data was sent even though device data is not registered.
Remedy: Check the transmission cable. There is the possibility of ghost characters being sent.
------------------------------
Code: 1106040A
Display:
Used by:
Cause: The number of elements in element data has exceeded the limit.
Remedy: None.
------------------------------
Code: 11060500
Display:
Used by:
Cause: A command to start data check was sent during data check.
Remedy: None.
------------------------------
Code: 11060501
Display:
Used by:
Cause: A checksum error occurred during data transmission.
Remedy: Check the transmission cable. There is the possibility of ghost characters being sent.
------------------------------
Code: 11060502
Display:
Used by:
Cause: A character number check error occurred during data transmission.
Remedy: Check the transmission cable. There is the possibility of ghost characters being sent.
------------------------------
Code: 11060600
Display:
Used by:
第 190 页