FUJI错误代码查询.pdf - 第695页

Used by: QP3,NP2 Cause: Remedy: Check if the <sub-slot number> for the MPRXY4 command falls outside the 1-2 range. ------------------------------ Code: 12068C8F Display: MPRXY4 <axis> data error! Used by: QP3…

100%1 / 5282
------------------------------
Code: 12068C86
Display: MPRXY2 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY2 command falls outside the 1-2 range.
------------------------------
Code: 12068C87
Display: MPRXY2 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY2 command falls outside the 0-1 range.
------------------------------
Code: 12068C88
Display: Check if the <input method> for the MPRXY3 command falls outside the 0-2 range.
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY3 command falls outside the 0-2 range.
------------------------------
Code: 12068C89
Display: MPRXY3 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY3 command falls outside the 21-30 range.
------------------------------
Code: 12068C8A
Display: MPRXY3 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY3 command falls outside the 1-2 range.
------------------------------
Code: 12068C8B
Display: MPRXY3 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY3 command falls outside the 0-1 range.
------------------------------
Code: 12068C8C
Display: MPRXY4 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY4 command falls outside the 0-2 range.
------------------------------
Code: 12068C8D
Display: MPRXY4 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY4 command falls outside the 31-40 range.
------------------------------
Code: 12068C8E
Display: MPRXY4 <sub-slot number> data error!
第 694 页
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY4 command falls outside the 1-2 range.
------------------------------
Code: 12068C8F
Display: MPRXY4 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY4 command falls outside the 0-1 range.
------------------------------
Code: 12068C90
Display: MPRXY5 <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRXY5 command falls outside the 0-2 range.
------------------------------
Code: 12068C91
Display: MPRXY5 <slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <slot number> for the MPRXY5 command falls outside the 41-50 range.
------------------------------
Code: 12068C92
Display: MPRXY5 <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRXY5 command falls outside the 1-2 range.
------------------------------
Code: 12068C93
Display: MPRXY5 <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRXY5 command falls outside the 0-1 range.
------------------------------
Code: 12068CA0
Display: MPRZ <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRZ command falls outside the 0-1 range.
------------------------------
Code: 12068CA1
Display: MPRZ <sub-slot number> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <sub-slot number> for the MPRZ command falls outside the 1-2 range.
------------------------------
Code: 12068CB0
Display: MPRORG <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRORG command falls outside the 0-2 range.
第 695 页
------------------------------
Code: 12068CB1
Display: MPRORG <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRORG command falls outside the 0-2 range.
------------------------------
Code: 12068CC0
Display: MPRRMV <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRRMV command falls outside the 0-2 range.
------------------------------
Code: 12068CC1
Display: MPRRMV <data> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <data instruction> for the MPRRMV command falls outside the 0-3 range.
------------------------------
Code: 12068CD0
Display: MPRFEE <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRFEE command falls outside the 0-1 range.
------------------------------
Code: 12068CD1
Display: MPRFEE <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRFEE command falls outside the 0-2 range.
------------------------------
Code: 12068CE0
Display: MPRCNV <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRCNV command falls outside the 0-1 range.
------------------------------
Code: 12068CE1
Display: MPRCNV <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRCNV command falls outside the 0-2 range.
------------------------------
Code: 12068CF0
Display: MPRSRV <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRSRV command falls outside the 0-1 range.
------------------------------
Code: 12068CF1
Display: MPRSRV <axis> data error!
第 696 页