FUJI错误代码查询.pdf - 第140页

Remedy: Check the setting for Language in the Proper data at the MCS, and retransmit the Proper data. Select either English, French, or Japanese. As French is currently not supported, English will display if French is se…

100%1 / 5282
Code: 1101F024
Display: 用于检测钢网插入方向的Mark点读取异常
Used by: GPX-C
Cause: 不能读取用于检测钢网插入方向的Mark点。
Remedy: 请确认钢网的插入方向。
------------------------------
Code: 1101F025
Display: 脱模等待时间超出范围
Used by: NXTP、GPXC
Cause: 脱模等待时间超出范围
Remedy: Flexa的设置中Process Option - Print Procedure - Snap-off wait time
的设置范围为0 - 10000[msec]。
------------------------------
Code: 1101F026
Display: 读取定位点类型异常。
Used by: GPX-C,GPX-CS
Cause: 读取定位点类型不合适。
Remedy: 请在生产程序编辑中将读取定位点类型变更为以下中的某一个。·补正用定位点 ·方向检查用定位点 ·无
法读取的定位点
------------------------------
Code: 1101F027
Display: 定位点数据下载失败。
Used by: NXTP,GPX-C,GPX-CS
Cause: 定位点数据下载失败。
Remedy: 请确认定位点的设定。关于引发异常的可能原因,请参考如下。
·未向机器分配定位点。
·分配了实际不存在的定位点名。
请执行数据确认并确认有无异常(要求:无异常)。
------------------------------
Code: 1101F028
Display: 定位点数量不合理。
Used by: NXTP,GPX-C,GPX-CS
Cause: 定位点数量不合理。
Remedy: 请确认下列条件。
·Fiducial定位点和Mask定位点的数量都不得少于2个且个数必须相同。
·定位点数量上限
Fiducial定位点和Mask定位点的坐标相同时→ 8个
Fiducial定位点和Mask定位点的坐标不一致时→ 4个
·是否向机器分配了定位点?
请执行数据确认并确认有无异常(要求:无异常)。
------------------------------
Code: 1101F029
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 11022001
Display: 11022001
Used by:
Cause: The "Language" setting is out of the range.
第 139 页
Remedy: Check the setting for Language in the Proper data at the MCS, and retransmit the Proper data.
Select either English, French, or Japanese. As French is currently not supported, English will display if
French is selected.
------------------------------
Code: 11022002
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6N,CP65,CP652C,CP642,CP643,IP2,IP3
Cause: The Proper "Device Check Port" is out of range.
Remedy: Check Proper data's "Device Check Port." When using the optional Handy Terminal this must be
set. Normally, to avoid communication board jumper setting problems, this is set to "1." This is the first
connector from the top of the board. This is set before the machine is delivered.
------------------------------
Code: 11022003
Display:
Used by: IP3
Cause: Device check terminal (ex.: Handy Terminal) communication port has been previously specified
elsewhere.
Remedy: Specify the correct value in Proper data's 73.Device Check port.
------------------------------
Code: 11022004
Display:
Used by: IP3,QP132
Cause: Verifier tool is not set correctly.
Remedy: Specify the correct value in Proper data's 71.Verifier Tool.
------------------------------
Code: 11022005
Display:
Used by: IP3,QP132
Cause: The device check is specified to operate but the device check terminal is set to not operate, and
both ESC Permission and MAN Permission are set to "Non."
Remedy: If the device check is specified to operate but the device check terminal is set to not operate,
either 74.ESC Permission or 75.MAN Permission must be set to "Permit." Alternately, specify that the
device check not be used, or specify that a device check terminal be used.
------------------------------
Code: 11022006
Display: 11022006
Used by: GSP5
Cause: The Proper data cannot be transmitted because the MCS version is old.
Remedy: The machine software version has been upgraded to include additions to the Proper data and
therefore it is not compatible with the present version of MCS. Upgrade the MCS software. As a
temporary measure, return the machine to the original software version until the upgraded version of MCS
is received.
------------------------------
Code: 11022007
Display: Same as code.
Used by: SECS/GEM
Cause: The bit setting in "Machine_status A" (fourth bit from the right) which enables remote commands
is set to "0" or the value for the item "LMS_flag" is set to "0".
Remedy: Ensure that both of these are set to "1" when using SECS/GEM.
------------------------------
Code: 11022300
第 140 页
Display: 11022300
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,IP3,QP132
Cause: The data does not match machine specifications (FCP5, FCP6, FCP6-5, FCP6-M).
Remedy: Check the Proper data and transmit again.
1. Print out the Proper data, and after inputting new Proper data, transmit it to the machine.
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
------------------------------
Code: 11022321
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: X0, Y0 out of range (less than or equal to zero).
Remedy: Check X0, Y0 in Proper data.
------------------------------
Code: 11022322
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: XL, YL data out of range (<=0).
Remedy: Check XL, YL in Proper data.
------------------------------
Code: 11022323
Display:
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: cam_speed out of range (<=100 or >=1706).
Remedy: Check cam_speed in Proper data.
------------------------------
Code: 11022324
Display:
Used by: CP3
Cause: Q_data out of range (<-1 or >=3600).
Remedy: Check Q_data in Proper data.
------------------------------
Code: 11022325
Display:
Used by: CP3
Cause: R_data out of range (<-1 or >=3600).
Remedy: Check R_data in Proper data.
------------------------------
Code: 11022326
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: dl_position out of range (<-1 or >=3600).
Remedy: Check dl_position in Proper data.
------------------------------
Code: 11022327
Display:
Used by: CP3
Cause: ccd_x or ccd_y is 0.
Remedy: Check ccd_x and ccd_y in Proper data.
------------------------------
Code: 11022328