FUJI错误代码查询.pdf - 第1136页

Used by: CP-732E, CP-742ME, CP-742E Cause: The out-carrier panel sensors 1 and 2 (X0CC, X0CD) failed to switch on even though 2 panel s were loaded from the XY-table. In systems with a panel present memory, the panel pre…

100%1 / 5282
Remedy: The clamper must be closed in order to move the XY-table to the middle loading position. Check
to see if the out-carrier clamper is closed. If closed, and if this error occurs anyway, adjust the sensor
mounting position.
------------------------------
Code: 15040418
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carriers advance limit and retract limit sensors are both off.
Remedy: Move the out-carrier to either the advance limit or the retract limit position. If this error still
occurs, adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their
mounting positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040419
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier's advance limit and retract limit sensors are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041A
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's advance limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041B
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's advance limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041C
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's retract limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041D
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's retract limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041E
Display: Out-carrier panel conveyance error.
第 1135 页
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensors 1 and 2 (X0CC, X0CD) failed to switch on even though 2 panel s
were loaded from the XY-table. In systems with a panel present memory, the panel present/absent status
on the out-carrier was checked, but the out-carrier 1 panel sensor and the out-carrier 2 panel sensor
could not verify the presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the out-carrier, use the out-
carrier unclamp command to open the out-carrier. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 1504041F
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensor 1 (X0CC) failed to switch on even though 1 panel was loaded from
the XY-table. In systems with a panel present memory, the panel present/absent status on the out-carrier
was checked, but the out-carrier 1 panel sensor could not verify the presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the out-carrier, use the out-
carrier unclamp command to open the out-carrier. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040420
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensor failed to switch on even though a panel was conveyed from the XY-
table to the out-carrier.
Remedy: Check to see if the panel has been conveyed properly to the our-carrier. If the error persists
even though the panel conveyance has occurred properly, adjust the sensor mounting position.
------------------------------
Code: 15040421
Display: Out-lifter logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP and DOWN limit sensors are both off.
Remedy: Move the out-lifter to either the UP or DOWN limit position, and if the error still occurs, readjust
the sensor mounting position. If the sensor still fails to switch on even after adjusting its mounting
position, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040422
Display: Out-lifter logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP and DOWN limit sensors are both on.
Remedy: Readjust the sensor mounting position. If the sensor still fails to switch off even after adjusting
its mounting position, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040423
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter panel sensors 1 and 2 (X0C7, X0C9) failed to switch on even though 2 panel s were
loaded from the out-carrier.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040424
第 1136 页
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter panel sensor 1 (X0C7) failed to switch on even though 1 panel was loaded from the
out-carrier.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040425
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The interval between the first and second panel s is incorrect. Alternatively, the interval sensor
(X0CA) is mounted in the wrong position.
Remedy: If this error occurs when both the interval setting data and the sensor mounting position are
correct, check to see if the interval sensor is operating correctly. This sensor should be on when no panel
is detected.
------------------------------
Code: 15040426
Display: Panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Error occurred during panel conveyance at the out-conveyor. After panel conveyance was
started, the panel failed to arrive at the out-conveyor's panel arrival sensor (X0CB) position within the
prescribed period of time.
Remedy: Check to see if the panel is stuck. If so, adjust the conveyor width to accommodate the panel .
If this error occurs even though the panel has in fact arrived, check the sensor operation.
------------------------------
Code: 15040427
Display: Panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Loader idling cannot be performed because a panel is present in the machine.
Remedy: Unload all panel s from the machine.
------------------------------
Code: 15040428
Display: 次工程电路板搬运异常
Used by: CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP
Cause: 在向下工序搬运电路板中发生了异常。
虽然向下工序送出了送出侧的电路板,但是在下工序中无法正常地搬运电路板,在规定时间(15秒)内来自下工序的
电路板要求信号没有OFF。
Remedy: 请调整下工序的搬运轨道宽度,以保证电路板能够传送。
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040428.PNG">
------------------------------
Code: 15040429
Display: Out-conveyor mid-stopper error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-conveyor mid-stopper ON limit sensor failed to switch on. Although the out-conveyor
mid-stopper was switched off, the OFF limit sensor failed to switch on within the prescribed period of time
(3 secs.).
Remedy: If this error occurs even though both the stopper ON and OFF limit sensors switch on within the
prescribed period of time, with the stopper operating correctly, check the operation of the sensors (X0C4,
X0C5).
------------------------------
第 1137 页