Display: IC Direction ERROR D*** Used by: IP1,IP2,IP3 Cause: The results of the first pin check are that the part is not oriented correctly and the operation has been cancelled. Remedy: Check the orientation of the part.…
Remedy: Check for interference with the Z-axis.
------------------------------
Code: 12044105
Display: XY-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the Y-axis during movement to the empty-tray pick-up position.
Remedy: Check for interference with the Y-axis.
------------------------------
Code: 12044106
Display: Z-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the Z-axis during movement to the empty-tray pick-up position.
Remedy: Check for interference with the Z-axis.
------------------------------
Code: 12046001
Display: Plt ID Battery Check
Used by:
Cause: There is no response from the ID card on the UP lifter.
Remedy: Replace the ID card battery, or the ID card itself.
------------------------------
Code: 12046002
Display: Pallet ID Read Error
Used by: CP5
Cause: The ID on the pallet on the UP lifter could not be read.
Remedy: Check that the ID reading location has not moved. Alternately, replace the ID card.
------------------------------
Code: 12046003
Display:
Used by:
Cause: Next pallet changeover could not be performed.
Remedy: Check the next pallet or re-supply the parts.
------------------------------
Code: 1204A001
Display: VF Comp Er (*) D No. ***
Used by:
Cause: The measurement results are too small.
Remedy: Check whether the part has been set correctly. Alternately, the part is defective.
------------------------------
Code: 1204A002
Display: VF Comp Er (*) D No. ***
Used by:
Cause: The measurement results are too large.
Remedy: Check whether the part has been set correctly. Alternately, the part is defective.
------------------------------
Code: 1204A003
Display: VF Comp Er (*) D No. ***
Used by: CP3
Cause: The measurement results are out of range.
Remedy: Check whether the part has been set correctly. Alternately, the part is defective.
------------------------------
Code: 1204A101
第 479 页
Display: IC Direction ERROR D***
Used by: IP1,IP2,IP3
Cause: The results of the first pin check are that the part is not oriented correctly and the operation has
been cancelled.
Remedy: Check the orientation of the part. Also, check that the check area set in Part data, and the CCD
level is correctly set. Note: D** in the display refers to the device number.
------------------------------
Code: 1204A102
Display: Orientation check error!
Used by: QP301
Cause: The tray supply direction may be incorrect.
Remedy: Check the tray supply direction.
------------------------------
Code: 1204A201
Display:
Used by: CP3,CP4-1,CP4-2,CP3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP1,IP2,QP132
Cause: This is a production data code indicating that parts were dumped at the resumption of
production after operation was interrupted (emergency stop etc.).
Remedy: None
------------------------------
Code: 1204A202
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,QP132
Cause: This is a production data code indicating that parts were dumped using commands by the
operator.
Remedy: None
------------------------------
Code: 1204A203
Display:
Used by:
Cause: With the cam at 100 deg. the axis check (I, X, Y, D axes) could not be finished in the allotted
time. Because of this, when the part is at station 5 it is impossible to determine whether or not the part
can be placed without an error. Therefore, the part is rejected, and recovery is carried out.
Remedy: If this error occurs often, servo adjustment is necessary. Contact Fuji.
------------------------------
Code: 1204A204
Display:
Used by:
Cause: The 100 deg. rough position check for the X and Y axes could not be performed at the machine
within the preset time. Therefore, when the part was at station 5 there was no guarantee that it would be
placed correctly, so the part was rejected and recovery carried out.
Remedy: If this error happens frequently, the servos need adjusment. Contact Fuji.
------------------------------
Code: 1204A205
Display:
Used by:
Cause: The 100 deg. rough position check for the I axis could not be performed at the machine within the
preset time. Therefore, when the part was at station 5 there was no guarantee that it would be placed
correctly, so the part was rejected and recovery carried out.
Remedy: If this error happens frequently, the servos need adjusment. Contact Fuji.
------------------------------
第 480 页
Code: 1204A206
Display:
Used by:
Cause: The 100 deg. rough position check for the D axis could not be performed at the machine within
the preset time. Therefore, when the part was at station 5 there was no guarantee that it would be placed
correctly, so the part was rejected and recovery carried out.
Remedy: If this error happens frequently, the servos need adjusment. Contact Fuji.
------------------------------
Code: 1204A207
Display:
Used by:
Cause: The 100 deg. rough position check for each axis (vision processing) could not be performed at the
machine within the preset time. Therefore, when the part was at station 5 there was no guarantee that it
would be placed correctly, so the part was rejected and recovery carried out.
Remedy: If this error happens frequently, the servos need adjusment. Contact Fuji.
------------------------------
Code: 1204A208
Display:
Used by:
Cause: Automatic operation has been canceled due to a rear fence alarm. The nozzle at station 1 is not
set so it is impossible to determine which part has been picked. This error occurs only on the FCP-IV due
to the method in which the emergency stop is carried out.
Remedy: The part in question is discarded and auto-recovery is carried out.
------------------------------
Code: 1204A210
Display: Reject conveyor error!
Used by: NP2,QP3
Cause: Failed to reject part onto the reject parts conveyor.
Remedy: Check the condition of the parts reject conveyor.
------------------------------
Code: 1204A211
Display: Reject conveyor error!
Used by: QP3
Cause: A part that is to be rejected is set to be rejected to the conveyor but a reject parts conveyor that
can handle the rejected part cannot be found.
Remedy: Parts cannot be rejected when the part size in the both the X- and Y-direction exceeds the
conveyor width. Set a reject parts conveyor that can handle the part.
If locations other than the conveyor can be used for the rejected part, change the [Reject Position]
setting in part data to a location that can handle the part.
------------------------------
Code: 1204A212
Display: Eject conveyor error
Used by: QP3
Cause: The part cannot be rejected as the part dimensions (X and Y) are greater than the width of the
conveyor.
Remedy: Prepare a conveyor suitable for the part size.
------------------------------
Code: 1204A213
Display: Reject conveyor error!
Used by: QP3
Cause: The conveyor was specified for rejecting parts but the reject parts conveyor was not ready.