Used by: QP3 Cause: Deviation (3σ) exceeded 20[gf]. Specified pressure could not be reproduced. Remedy: Carry out regular placing pressure zero adjustment again. ------------------------------ Code: 12060313 Display: Use…
------------------------------
Code: 12056175
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12056176
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12056177
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12056178
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12056179
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1205617A
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1205617B
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1205617C
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12057001
Display: Regular placing pressure control alarm
第 596 页
Used by: QP3
Cause: Deviation (3σ) exceeded 20[gf]. Specified pressure could not be reproduced.
Remedy: Carry out regular placing pressure zero adjustment again.
------------------------------
Code: 12060313
Display:
Used by:
Cause: There is a screen in the backside cleaning position so the collect command cannot be executed.
Remedy: Remove the screen from the backside position and execute the collect command.
------------------------------
Code: 12061001
Display: CHECK HANDLE
Used by: CP3,CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The handle which turns the cam axis is not in its rest position.
Remedy: Return the handle to its original position.
------------------------------
Code: 12061002
Display: CHECK NOZZLE
Used by: CP3,CP4-1,CP4-2,CP4-3
Cause: The nozzle at station 9 is lowered (CP).
Remedy: Return the nozzle to its original position.
------------------------------
Code: 12061003
Display: CHECK 5ST NZL
Used by: CP3
Cause: The nozzle orientation was not returned to 0 deg at station 12 so the machine stopped when it
reached station 5 (CP).
Remedy: Adjust the rotating mechanisms at stations 5 and 12. If the nozzle was rotated during nozzle
change, cut the power and move the nozzle back to 0 deg. by hand.
------------------------------
Code: 12061004
Display: D ORG POS NG
Used by: CP3,CP4-1,CP4-2
Cause: The table is not at the resupply position (CP).
Remedy: Return the table to the resupply position.
------------------------------
Code: 12061005
Display: NOZZLE SKIP1 OVER
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: There are too many nozzles skipping (CP).
Remedy: Check the nozzles that are skipping.
------------------------------
Code: 12061007
Display: MAX Dno ERROR
Used by:
Cause: The specified device number is too large (CP).
Remedy: Operate in joint mode.
------------------------------
Code: 12061008
Display: VF Probe Er
Used by: CP3
第 597 页
Cause: Either the very fine tool probe does not advance, or it does not retract.
Remedy: Adjust the probe.
------------------------------
Code: 12061009
Display: VF Meter Er
Used by: CP3
Cause: Data was not returned from the very fine tool or from the LCR meter.
Remedy: Check that the connector and the lines have not been cut.
------------------------------
Code: 1206100A
Display: CHECK CAM
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam axis was not returned to the zero position.
Remedy: Using the cam handle, return the cam to the zero position.
------------------------------
Code: 1206100B
Display: Carrier Position Err. IN
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis in position is the Proper data Pallet Position DF
IN plus 500. Inch the axis to a point in this range.
------------------------------
Code: 1206100C
Display: Carrier Position Err. WORK
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis in position is the Proper data Pallet Position DF
IN plus 500. The D axis out position is the Proper data Pallet Position DF OUT minus 500. Inch the axis
to a point in this range.
------------------------------
Code: 1206100D
Display: Carrier Position Err. OUT
Used by: CP5
Cause: The D axis carrier is not at its target position.
Remedy: Inch the carrier to its target position. The D axis out position is the Proper data Pallet Position
DF OUT minus 500. Inch the axis to a point in this range.
------------------------------
Code: 1206100E
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: A nozzle has hit the parts in the rejected parts box.
Remedy: Empty the box.
------------------------------
Code: 1206100F
Display:
Used by: CP5
Cause: The Z origin position (Z0) in the machine has changed.
Remedy: Check that the coupling is not loose. If adjustments are necessary, readjust the Z axis.
------------------------------
Code: 12061010
Display: Coolant oil circulat prob.(cp6)
第 598 页