------------------------------ Code: 1CB06003 Display: 1CB06003 Used by: NP133 Cause: The vision window used to calculate the histogram is larger than the image range. Remedy: Check whether the entered diameter for the n…
Cause: The scan area is too narrow.
Remedy: The minimum scan area is 0.2 millimeters. Make sure that the mark data description in the
production program is correct.
------------------------------
Code: 1CB04003
Display: 1CB04003
Used by: GL541
Cause: The glue could not be found.
Remedy: The minimum glue size is 0.008 square millimeters. Verify that the glue does exist in the scan
area. Make sure the mark data glue color in the production program is correct. Verify that the glue is
clearly reflected in the image. Adjust the gain and/or offset of the mark camera if the contrast is not
easily discernible.
------------------------------
Code: 1CB04004
Display: 1CB04004
Used by: GL541
Cause: The glue lies outside of the scan area.
Remedy: Make sure the glue dot is not too big in relation to the scan area due to stringing or excessive
dispensing force. Make sure the scan area is not too narrow in relation to the glue. Also check the mark
data description in the production program for any mistakes.
------------------------------
Code: 1CB05001
Display: 1CB05001
Used by: NP133
Cause: The entered range is larger than the image range.
Remedy: Check the entered range.
------------------------------
Code: 1CB05002
Display: 1CB05002
Used by: NP133
Cause: The calculated average is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB05003
Display: 1CB05003
Used by: NP133
Cause: The calculated standard deviation is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06001
Display: 1CB06001
Used by: NP133
Cause: The entered parameter is outside the permissible range.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06002
Display: 1CB06002
Used by: NP133
Cause: The nozzle cannot be detected because of a lack of contrast.
Remedy: Because of a lack of contrast, the vision system cannot determine between the nozzle and the
nozzle disk. Check for deterioration in the nozzle disk sticker and the light source.
第 1206 页
------------------------------
Code: 1CB06003
Display: 1CB06003
Used by: NP133
Cause: The vision window used to calculate the histogram is larger than the image range.
Remedy: Check whether the entered diameter for the nozzle reflective disk is larger than the image range.
Check that there are no marks on the reflective surface which could be mistaken for the nozzle.
------------------------------
Code: 1CB06004
Display: 1CB06004
Used by: NP133
Cause: The calculated average is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06005
Display: 1CB06005
Used by: NP133
Cause: The calculated standard deviation is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB07001
Display: 1CB07001
Used by:
Cause: Data required for processing has not been entered.
Remedy: Specify the mark size, camera resolution, and window size.
------------------------------
Code: 1CB07002
Display: 1CB07002
Used by:
Cause: Mark is too large.
Remedy: Specify the setting so that mark fits in the window.
------------------------------
Code: 1CB07003
Display: 1CB07003
Used by:
Cause: Window area (range) is incorrect.
Remedy: Specify the window range so that the window fits in the screen.
------------------------------
Code: 1CB07004
Display: 1CB07004
Used by:
Cause: No image contrast.
Remedy: Check to see if the image is being acquired properly. Also verify that the nozzle is correct.
------------------------------
Code: 1CB07005
Display: 1CB07005
Used by:
Cause: No mark at the specified position.
Remedy: Check to see if the wrong position was specified.
------------------------------
Code: 1CB07006
第 1207 页
Display: 1CB07006
Used by:
Cause: Mark is distorted.
Remedy: Verify that the entire mark fits in the window.
------------------------------
Code: 1CB07007
Display: 1CB07007
Used by:
Cause: Mark size exceeds the tolerance range.
Remedy: Increase the tolerance value.
------------------------------
Code: 1CC01001
Display: 1CC01001
Used by:
Cause: The check window is outside of the scan area.
Remedy: Check the coordinates of the check window.
------------------------------
Code: 1CC01002
Display: 1CC01002
Used by:
Cause: The specified window size is unsuitable.
Remedy: Check the window area specified at the MCS.
------------------------------
Code: 1CC01003
Display: 1CC01003
Used by: IP3
Cause: A vision processing error occurred during the part polarity check.
Remedy: Check the direction in which the parts are supplied.
------------------------------
Code: 1CC01101
Display: 1CC01101
Used by:
Cause: The value input for the back light diameter is 0.
Remedy: Input the correct back light diameter in part data.
------------------------------
Code: 1CC02001
Display: 1CC02001
Used by:
Cause: The check window is outside of the scan area.
Remedy: Check the coordinates of the check window.
------------------------------
Code: 1CC02002
Display: 1CC02002
Used by:
Cause: The specified window size is unsuitable.
Remedy: Check the window area specified at the MCS.
------------------------------
Code: 1CC02003
Display: 1CC02003
Used by:
Cause: A vision processing error occurred during the part polarity check.