Cause: The return-conveyor's stopper is not engaging. Remedy: Check operation using I/O commands (XO4C: RCV STPR ON) and adjust if necessary. ------------------------------ Code: 15040631 Display: RCV_STOPPER DOWN T…
------------------------------
Code: 1504060E
Display: OUT INTERLOCK SS NOT ORG POS
LD_ERR 1504060E
Used by:
Cause: The SS-axis is not at its origin position.
Remedy: Move the SS-axis to its origin position.
------------------------------
Code: 15040610
Display: SHUTTER OPEN TIMEUP
Loader error: 15040610
Used by: QP132
Cause: The opening operation of the unload shutter was not completed within the set amount of time.
Remedy: Check the unload shutter operation and the operation of the shutter open check sensor.
------------------------------
Code: 15040611
Display: SHUTTER CLOSE TIMEUP
Loader error: 15040611
Used by: QP132
Cause: The closing operation of the unload shutter was not completed within the set amount of time.
Remedy: Check the unload shutter operation and the operation of the shutter close check sensor.
------------------------------
Code: 15040620
Display: PALLET ON UNLOADER
Loader error: 15040620
Used by: QP132
Cause: Unloader conveyor pallet arrival sensor 1 was on when the machine attempted indexing during
initiation or pallet switchover.
Remedy: The ID reader at the OUT end is misreading, or the unloader conveyor is malfunctioning. Adjust
the machine.
------------------------------
Code: 15040621
Display: SS INTERLOCK EMERGENCY
Loader error: 15040621
Used by: QP132
Cause: The OUT conveyor pallet check sensor was on while the SS-axis was transporting a pallet.
Remedy: Check whether there is an unnecessary pallet on the unloader, or make sure the OUT conveyor
pallet confirmation sensor isn't malfunctioning.
------------------------------
Code: 15040622
Display: "SS INTERLOCK ERROR", "LD_ERR 15040622"
Used by:
Cause: The OUT conveyor pallet check sensor was on when the SS-axis was performing a pallet transport
start check..
Remedy: Check whether there is an unnecessary pallet on the unloader, or make sure the OUT conveyor
pallet confirmation sensor isn't malfunctioning.
------------------------------
Code: 15040630
Display: RCV_STOPPER RIZE TUP
Loader error: 15040630
Used by: QP132
第 1148 页
Cause: The return-conveyor's stopper is not engaging.
Remedy: Check operation using I/O commands (XO4C: RCV STPR ON) and adjust if necessary.
------------------------------
Code: 15040631
Display: RCV_STOPPER DOWN TUP
Loader error: 15040631
Used by: QP132
Cause: The return-conveyor's stopper is not disengaging.
Remedy: Check operation using I/O commands (XO4D: RCV STPR OFF) and adjust if necessary.
------------------------------
Code: 15040632
Display: RCV PLT NOT ARRV
Loader error: 15040632
Used by: QP132
Cause: An unloaded pallet has not arrived at the deceleration point.
Remedy: Check that the pallet is not somewhere other than the stopping position on the return-conveyor.
Check operation using I/O commands (X048: RCV DECEL PNT) and adjust if necessary.
------------------------------
Code: 15040633
Display: RCV PLT NOT EXIST
Loader error: 15040633
Used by: QP132
Cause: The pallet that passed through the return-conveyor's deceleration point has not arrived at the
pallet arrival check sensor.
Remedy: Check that the pallet is not somewhere in between the deceleration point and the arrival
verification position on the return-conveyor. Check operation using I/O commands (X049: RCV ARRV
CHK) and adjust if necessary.
------------------------------
Code: 15040634
Display: RCV_STOPPER2 RIZE TUP
Loader error: 15040634
Used by: QP132
Cause: The return-conveyor's stopper2 is not engaging.
Remedy: Check operation using I/O commands (XO6E: RCV STPR2 ON) and adjust if necessary.
This error only occurs when the machine is operated with 12 sixteen-inch pallets.
------------------------------
Code: 15040635
Display: RCV_STOPPER2 DOWN TUP
Loader error: 15040635
Used by: QP132
Cause: The return-conveyor's stopper2 is not disengaging.
Remedy: Check operation using I/O commands (XO77: RCV STPR2 OFF) and adjust if necessary.
This error only occurs when the machine is operated with 12 sixteen-inch pallets.
------------------------------
Code: 15040636
Display: RCV2 PLT NOT ARRV
Loader error: 15040636
Used by: QP132
Cause: An unloaded pallet has not arrived at the deceleration point2.
Remedy: Check that the pallet is not somewhere other than the stopping position on the return-conveyor.
Check operation using I/O commands (X065: RCV DECEL PNT2) and adjust if necessary.
第 1149 页
This error only occurs when the machine is operated with 12 sixteen-inch pallets.
------------------------------
Code: 15040637
Display: RCV2 PLT NOT EXIST
Loader error: 15040637
Used by: QP132
Cause: The pallet that passed through the return-conveyor's deceleration point2 has not arrived at the
pallet arrival check sensor.
Remedy: Check that the pallet is not somewhere in between the deceleration point2 and the arrival
verification position on the return-conveyor. Check operation using I/O commands (X069: RCV ARRV2
CHK) and adjust if necessary.
This error only occurs when the machine is operated with 12 sixteen-inch pallets.
------------------------------
Code: 15040754
Display: LD PCB CLAMP TUP
Loader error: 15040754
Used by: QP132
Cause: The loaded pallet closed check (X045: P.IN PLT CLS) did not come on in the given time .
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040755
Display: LD PCB UNCLAMP TUP
Loader error: 15040755
Used by: QP132
Cause: The unloaded pallet open check (X044: P.IN PLT OPN) did not come on in the given time .
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040760
Display: LD BACKWARD TUP
Loader error: 15040760
Used by: QP132
Cause: The pallet load cylinder retract sensor (X043: P.IN BWEND) did not come on in the given time
(QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040761
Display: LD FORWARD TUP
Loader error: 15040761
Used by: QP132
Cause: The pallet load cylinder extend sensor (X042: P.IN FWEND) did not come on in the given time
(QP132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040762
Display: LD PLT CLAMP TUP
Loader error: 15040762
Used by: QP132
Cause: The loaded pallet unclamp check sensor (X053: P.IN PLT UCLP) did not turn off in the given
time(QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------