Used by: CP643,CP643M Cause: Main conveyor movement for the conveyance of board(s) was terminated because the out-carrier is out of position. Remedy: If the out-carrier is at its extended position, check the extended and…

100%1 / 5282
be OFF.
Remedy: Make sure the out-carrier board sensors (the I/O input signals listed below) tuen ON and OFF
correctly.
I/O input signals:
LX038: OUT-carrier 1 board sensor
LX039: OUT-carrier 2 board sensor
------------------------------
Code: 15010D05
Display: Cylinder cycle alarm:O_CRRY
O_CRRY board transfer time up
Used by: CP643
Cause: The out-carrier was extended,but the extended limit sensor did not turn ON within the specified
time.
The out-carrier was retracted,but the retracted limit sensor did not turn ON within the specified time.
The out-carrier extended and retracted limit sensors are both ON.
Remedy: Make sure the out-carrier extends and retracts smoothly.
Make sure the extended and retracted limit sensors have been attached at the correct positions.
Make sure the extended and retracted limit sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the extended and retracted limit sensors (the I/O input signals listed below) turn ON and OFF
correctly when the out-carrier is extended and retracted.
I/O input signals:
LX03C: OUT-carrier extended limit sensor
LX03D: OUT-carrier retracted limit sensor
------------------------------
Code: 15010D06
Display: Interlock alarm:O_CRRY
Used by: CP643
Cause: The machine was not able to extend the out-carrier because there is a board in the out-lifter,but
it was not sure whether there is a board clamped in the out-carrier. If the out-carrier has clamped a board
with parts mounted on the reverse side, there may be interference between the board and the one in the
out-lifter.
The machine was not able to retract the out-carrier because there is a board on
the out-lifter,and there is also a board clamped in the extended out-carrier.if
the board clamped in the out-carrir has parts mounted on the reverse side,there
may be interference between this board and the one on the out-lifter.
The machine was not able to retract the out-carrier from a position between the
extended limit and the retracted limit because there is a board on the out-lifter,but it is not sure whether
there is a board clamped in the out-carrier.if the
out-carrier has clamped a board with parts mounted on the reverse side,there may be interference
between this board and the one on the out-lifter.
Remedy: Remove any boards from in the out-lifter.
Make sure the out-lifter board arrival sensors (the I/O input signals listed below) detect the presence of
boards in the out-lifter.
I/O input signals:
LX00C: OUT1/OUT2 board gap sensor
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010D07
Display: Interlock alarm:O_CRRY
Out-carrier not at extended position.
第 1101 页
Used by: CP643,CP643M
Cause: Main conveyor movement for the conveyance of board(s) was terminated because the out-carrier
is out of position.
Remedy: If the out-carrier is at its extended position, check the extended and unclamping limit sensors.If
the extended and unclamping limit sensors are on, the carrier may be moving too fast and has recoiled out
of position.If the carrier is not at its extended position the movement of the carrier itself may require
adjustment.
------------------------------
Code: 15010D08
Display: Board-clamper error:O_CRRY
The clamp confirmation sensor on the OUT-carrier forward limit is unstable.
Used by: CP643,CP643M
Cause: The clamp sensor operation is unstable at the out-carrier's advance limit side.
Remedy: Check the clamp sensor operation, and verify that the conveyor width is suitable for the panel in
question.
------------------------------
Code: 15021000
Display: Remove Board from Main Cvyr
Used by: IP3
Cause: Either there was a main conveyor board check sensor alarm or the sensor is not correctly
adjusted. The board was moved by hand.
Remedy: If the board has been produced, unload it. If not, put the board back into the in conveyor.
------------------------------
Code: 15021001
Display: Not defined.
Used by:
Cause: Operation was cancelled because of an alarm from the application.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs frequently,
contact Fuji.
------------------------------
Code: 15021002
Display: Not defined.
Used by:
Cause: Loading position alarm.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs often contact
Fuji.
------------------------------
Code: 15021003
Display: Not defined.
Used by:
Cause: Lifter position error.
Remedy: Switch off the power to the machine and then re-start it. If the problem occurs often contact
Fuji.
------------------------------
Code: 15021004
Display: Interlock on(cp6)
Interlock Board transfer check(gsp5)
Used by: GSP5,GP551,GP6,IP3
Cause: The machine attempted to clamp the table while the board detect sensor on either the in or out-
conveyor was on.
Remedy: Remove the board.
第 1102 页
------------------------------
Code: 15021005
Display: Loader ROM Error.
Used by:
Cause: The software version in the board loader PLC ROM is newer than the software version in the
machine ROM. An error results when the PLC version is higher than the machine version.
Remedy: Contact Fuji.
------------------------------
Code: 15021006
Display: not in loading pos.
Used by: GSP5,GP2,GP551,GP3,GP6
Cause: The table was not in loading position when the lock/unlock function was attempted in order to
perform conveyor width adjustment.
Remedy: Perform the load position command to move the table to the loading position.
------------------------------
Code: 15021007
Display: Board pstn alarm main cnvyr
Used by: GSP5,GP551,GP6
Cause: The main conveyor board check is unclear, so the results of the check are that there is a board on
the main conveyor.
Remedy: Unload this board to the out conveyor.
------------------------------
Code: 15021008
Display: unrecognizable command
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: Either there is no Proper data measurement or zero setting was not performed.
Remedy: If there is no Proper data, transmit Proper to the machine. Then, perform zero setting.
------------------------------
Code: 15021009
Display: interlock
Used by: GSP5,GP551,GP6
Cause: The width adjustment clutch has not been released so the table cannot be moved.
Remedy: Remove the clutch using the loader unlock command. If the problem recurs, adjust the clutch
retract limit sensor.
------------------------------
Code: 1502100B
Display: Idle operation error!
Used by: NP2,QP3
Cause: The loader contains a PCB, even though the machine is in idle operation.
Remedy: Remove the PCB from the loader.
------------------------------
Code: 15024001
Display: Cycle alarm servo ??
Used by:
Cause: The servo did not reach its target position within the preset time limit.
Remedy: Check that there is no load on the servo axis.
------------------------------
Code: 15024002
Display: Cycle aiarm ??
Used by:
Cause: The cylinder did not reach its target position within the preset time limit.
第 1103 页