FUJI错误代码查询.pdf - 第2147页

Cause: The slot number value is not zero, but the stage number value is out of range. Remedy: There is a problem with a sequence field in the program file. Check that the file contents are correct. The stage number input…

100%1 / 5282
Remedy: There is a problem with the program file. Check that the file contents are correct.
------------------------------
Code: 23040035
Display: The nozzle specified by the program file does not exist in Nozzle Configuration File and Nozzle
Specification File. Do you want to continue?
Used by:
Cause: The nozzle specified in the program does not exist in the Nozzle Config. file and Nozzle Spec. file.
Remedy: Select [Yes] to ignore, and continue reading of the program file. Select [Abort] to cancel reading of
the program file.
------------------------------
Code: 23040036
Display: The following program file sequence's stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero,
placement cannot be performed as the slot cannot be determined.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 23040037
Display: The program file feeder setup stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero, feeders
cannot be allotted as the slot cannot be determined.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 23040039
Display: No compatible nozzle exists for this part.
Used by:
Cause: When creating the nozzle arrangement automatically, no nozzle diameter could be found within
the range defined by minimum nozzle diameter and maximum nozzle diameter in the part data.
Remedy: Check the minimum nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMI) and maximum
nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 2304003A
Display: The stage/slot numbers for the following placement sequence in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 2304003B
Display: The stage number value in the following sequence in the program file is out of range.
Used by:
第 2146 页
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 2304003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 50.
------------------------------
Code: 2304003D
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. When the stage number value is 2, the slot number input range is 1 to 450.
------------------------------
Code: 2304003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 50, and when stage 2 is specified, the slot number
input range is 1 to 450.
------------------------------
Code: 2304003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. The stage number input range is 1 to 2.
------------------------------
Code: 23040040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 1, the slot number input range is 1 to 50.
------------------------------
Code: 23040041
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct. When the stage number value is 2, the slot number input range is 1 to 450.
------------------------------
Code: 23040042
Display: There are more than 12 kinds of Nozzles specified (Too many for the Revolver).
第 2147 页
Used by:
Cause: When the nozzle array is set to automatic configuration, the number of necessary nozzles exceeds
the maximum number of nozzles on the revolver, 12.
Remedy: There is an error in the program file. Revise the nozzle specification file, or revise the nozzle
name, minimum nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMI) and maximum nozzle diameter
(PARTS/ENVDT/XP141ENVDT-/PENMA) fields in the part data.
------------------------------
Code: 23040044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP141ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP141ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23040045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Nozzle Name (PARTS/ENVDT/XP141ENVDT-
/PENNZN) in the part data.
------------------------------
Code: 23040047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23040048
Display: Two or more first slots (reference slot) have been specified for the same alternate feeder loop. The
Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 23040049
Display: Two or more first slots (reference slots) have been specified for the same alternate feeder loop.
The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
第 2148 页