FUJI错误代码查询.pdf - 第2174页

configuration"in the "Nozzle optimization"screen,check the nozzle set up on the machine. If optimization was performed using the "Use program nozzle configuration"setting,check the nozzle set up …

100%1 / 5282
Remedy: <XP142>Set Packaging to 1:Bulk,2:32mm Adhesive,3:12mm (no U-groove)Embossed,16or24mm
Embossed,5:8mm Paper or Embossed,12mm (U-groove)Embossed,or 7:32mm Embossed.
<XP242>Set Packaging to 0:Tray,2:32mm Adhesive,3:12mm (no U-groove)Embossed,16or24mm
Embossed,4:Stick Feeder,5:8mm Paper or Embossed,12mm (U-groove)Embossed,7:32mm and Over
Embossed or 9:Stick (U-groove)Feeder.
------------------------------
Code: 2307E000
Display: PlaceBefore is set to loop.
Used by:
Cause: Cannot optimize because PlaceBefore is set to loop.
Remedy: Do not set PlaceBefore to loop in the sequence data.
------------------------------
Code: 2307E001
Display: The stage-slot number does not match the packaging type in part data.
Used by:
Cause: A part number with a Packaging Type of "Tray"is set for a Feeder stage-slot number or a part
number with a Packaging Type other than "Tray"is set for a Tray stage-slot number.
Remedy: For Feeder stage-slot numbers,specify a part number with a Packaging Type other than
"Tray".For Tray stage-slot numbers,specify a part number with Packaging Type of "Tray".Another option is
to optimize selecting "Configure feeders automatically"under "Feeder configuration"in the "Feeder
optimization"screen.
------------------------------
Code: 2307E002
Display: The part number does not match that of the Alt丏Feeder.
Used by:
Cause: The slot designated as Alt丏Feeder has a part number different from the one currently being
used.
Remedy: Select an Alt丏Feeder that has a part number that is the same as the one currently being used.
------------------------------
Code: 2307E003
Display: An unavailable stage is set in the feeder setup data.
Used by:
Cause: Stage 2 is set in the feeder setup data for the single side parts supplying machine.
Remedy: Either delete the stage 2 feeder data,or move them to stage 1.
------------------------------
Code: 2307E004
Display: The part size or Scan Area X,Scan Area Y setting exceeds the scanning range that can be handled
by the camera.
Used by:
Cause: The part size or Scan Area X,Scan Area Y setting exceeds the scanning range that can be handled
by the camera.
Remedy: Specify a part size or Scan Area X,Scan Area Y setting value that is within the scanning range
that can be handled by the camera.
With the Pick-up Point Offset X and Pick-up Point Offset Y settings taken into account,the maximum
part size that may be specified is 20 mm 事20 mm,and the maximum scan area is 25 mm 事24 mm,
------------------------------
Code: 2307E005
Display: A nozzle that matches nozzle number **cannot be found.
Used by:
Cause: A nozzle that matches nozzle number **cannot be found.
Remedy: If optimization was performed using the "Use machine nozzle configuration"setting under "Nozzle
第 2173 页
configuration"in the "Nozzle optimization"screen,check the nozzle set up on the machine.
If optimization was performed using the "Use program nozzle configuration"setting,check the nozzle
set up in the program.
Otherwise,perform optimization using the "Configure nozzles automatically"setting.
------------------------------
Code: 2307E006
Display: The part cannot be picked up because it interferes with an adjacent nozzle.
Used by:
Cause: The part cannot be picked up because it interferes with an adjacent nozzle.
Remedy: If optimization was performed using the "Use machine nozzle configuration"setting under "Nozzle
configuration"in the "Nozzle optimization"screen,check the nozzle configuration on the machine.
If optimization was performed using the "Use program nozzle configuration"setting,check the nozzle
configuration in the program.
Otherwise,perform optimization using the "Configure nozzles automatically"setting.
------------------------------
Code: 2307E007
Display: The same name has been allocated to [Place Before]and [Reference]([Sequence Comment]).
Used by:
Cause: The same name has been allocated to the [Place Before]and [Reference]([Sequence
Comment])sequences.
Remedy: Specify different names for the [Place Before]and [Reference]([Sequence Comment])sequences.
------------------------------
Code: 2307E008
Display: Duplicate [Reference]([Sequence Comment])sequences exist for the same board.
Used by:
Cause: Duplicate [Reference]([Sequence Comment])sequences exist for the same board.
Remedy: Create sequences so that [Reference]([Sequence Comment])sequences are not duplicated for the
same board.
------------------------------
Code: 2307E009
Display: Optimization was performed using the [Fix feeder configuration]setting,but it is possible that
trays cannot be arranged.
Used by:
Cause: Feeder optimization/Feeder configuration was performed using the [Fix feeder configuration (Do
not change feeder positions)]setting,but it is possible that trays cannot be arranged.
Remedy: Check that trays can be arranged.
------------------------------
Code: 2307F000
Display: Optimizer system error.
Used by:
Cause: Optimizer system error.
Remedy: This is an internal error.This error should not occur under normal circumstances.Acquire trace
data and contact your Fuji representative.
------------------------------
Code: 2307F001
Display: Optimizer system error.
Used by:
Cause: Optimizer system error.
Remedy: This is an internal error.This error should not occur under normal circumstances.Acquire trace
data and contact your Fuji representative.
------------------------------
第 2174 页
Code: 2307F002
Display: Optimizer system error.
Used by:
Cause: Optimizer system error.
Remedy: This is an internal error.This error should not occur under normal circumstances.Acquire trace
data and contact your Fuji representative.
------------------------------
Code: 230A0000
Display: PDW is already active.
Used by: PDW
Cause: Cannot start the application because it is already running.
Remedy: Quit the PDW that is currently running.
------------------------------
Code: 230A0001
Display: The MuCap2 board may not be set up correctly.\nClosing PDW.
Used by: PDW
Cause: Failed to detect the video input board.
Remedy: Check that the video input board has been inserted at the PCI slot.
------------------------------
Code: 230A0002
Display: Cannot read image file.
Used by: PDW
Cause: Either the specified image file cannot be found, or the file format is not correct.
Remedy: Check that the file has been saved, and that the image file format is supported for display.
------------------------------
Code: 230A0003
Display: Template file creation error.
Used by: PDW
Cause: Failed to create the template file.
Remedy: Check there is enough disk space. If a file with the same name already exists, check that the file
permissions are not set to read only.
------------------------------
Code: 230A0004
Display: A mistake in the input value.
Used by: PDW
Cause: Characters other than numbers were input.
Remedy: Input numbers only.
------------------------------
Code: 230A0005
Display: Please enter a number.
Used by: PDW
Cause: Characters other than numbers were input.
Remedy: Input numbers only.
------------------------------
Code: 230A0006
Display: Please enter an integer.
Used by: PDW
Cause: Numbers other than integers were input.
Remedy: Input integers only.
------------------------------
Code: 230A0007
第 2175 页