Code: 2100F040 Display: Not set up holder in PCT Used by: Cause: This is a system error. Remedy: Re-install the software. ------------------------------ Code: 2100F041 Display: D_No. Pd **** Undefined Generic device data…
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03A
Display: Block skip sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03B
Display: Fiducial sequence is out of order
Used by:
Cause: The mask fiducial mark sequence has not been positioned properly.
Remedy: Check the sequences starting with the one for which the error displayed. The order of the
sequences should be as follows: mask fiducial mark sequence, block fiducial mark sequence, block skip
mark sequence, other block sequences, fiducial mark sequences other than for blocks, and other
sequences.
------------------------------
Code: 2100F03C
Display: Memory allocation error
Used by:
Cause: Memory space could not be allocated.
Remedy: Contact Fuji.
------------------------------
Code: 2100F03D
Display: Holder number is not definition
Used by:
Cause: The holder number is undefined.
Remedy: Input the holder number under the HM heading in the second page of sequence data.
------------------------------
Code: 2100F03E
Display: Beyond the limits of holder number
Used by:
Cause: A number outside the correct range (1-4 on the IP2) was entered.
Remedy: Check that numbers within the correct range have been entered.
------------------------------
Code: 2100F03F
Display: Holder number is not light with device number
Used by:
Cause: The holder number and the device number are not matched correctly.
Remedy: On the IP2, holder 1 covers devices 1 ~ 37 and 101 ~ 110, holder 2 covers devices 4 ~ 37, holder
3 covers devices 51 ~ 84 and holder 4 covers devices 51 ~ 87. Check that the holder number is not
specified outside this range.
------------------------------
第 2106 页
Code: 2100F040
Display: Not set up holder in PCT
Used by:
Cause: This is a system error.
Remedy: Re-install the software.
------------------------------
Code: 2100F041
Display: D_No. Pd **** Undefined Generic device data
Used by:
Cause: The **** generic device data item is undefined.
Remedy: Check the device that produced the error, and check that there is a GD file.
------------------------------
Code: 2100F042
Display: Undefined nozzle_assignment_table name
Used by:
Cause: The input nozzle assignment table name is undefined.
Remedy: Enter the nozzle assignment table name under the Nozzle_assignment_table heading of
Machine_data of the production program in use.
------------------------------
Code: 2100F043
Display: Nozzle_assignment_table not existed
Used by:
Cause: The nozzle assignment table does not exist.
Remedy: Create a nozzle assignment table.
------------------------------
Code: 2100F044
Display: Next device data rooping error
Used by:
Cause: An error occurred in the next device data loop.
Remedy: The next device numbers must eventually form a loop (i.e., return to the original device). Check
that this is the case.
------------------------------
Code: 2100F045
Display: This next device is on different pallet
Used by:
Cause: This next device is on another pallet.
Remedy: On the CP5, the next devices must all be on the same pallet.
------------------------------
Code: 2100F046
Display: Nozzle table does not match M/C type
Used by:
Cause: The nozzle assignment table is different from the machine type.
Remedy: Check the nozzle assignment table. Input the same nozzle assignment table name's machine
type under the program's "Nozzle_assignment_table" heading.
------------------------------
Code: 2100F047
Display: Nozzle_assignment_table file open error
Used by:
Cause: The nozzle assignment table could not be opened.
Remedy: Check the nozzle assignment table. Input the same nozzle assignment table name's machine
type under the program's "Nozzle_assignment_table" heading.
第 2107 页
------------------------------
Code: 2100F048
Display: Nozzle_assignment_table file load error
Used by:
Cause: The nozzle assignment table could not be loaded.
Remedy: Check the nozzle assignment table. Input the same nozzle assignment table name's machine
type under the program's "Nozzle_assignment_table" heading.
------------------------------
Code: 2100F049
Display: Mount or Glue or Dummyg sequence is out of order
Used by:
Cause: There are sequences after the cleaning sequences.
Remedy: Move the cleaning sequence to the end of the program. The cleaning sequence must be the final
sequence.
------------------------------
Code: 2100F04A
Display: NAT check error
Used by:
Cause: NAT check error.
Remedy: Refer to the NAT error that occurred at the same time (2100FE**).
------------------------------
Code: 2100F04B
Display: Could not fork ntchk task
Used by:
Cause: The NAT checker (NTCHK) could not be started.
Remedy: Reboot MCS or re-install the system.
------------------------------
Code: 2100F04C
Display: Default value is used if no data is entered
Used by:
Cause: The program structure and descriptor structure are different.
Remedy: This is a warning. Save and correct the file using the editor.
------------------------------
Code: 2100F04D
Display: Can't open environment file.
Used by:
Cause: An error occurred when an attempt was made to open the environment setting file.
Remedy: Install the environment setting file from the MCS/2 system disk to /h0/MCS2/.SYS.
------------------------------
Code: 2100F04E
Display: Can't read environment file.
Used by:
Cause: An error occurred when the environment setting file was read.
Remedy: Install the environment setting file from the MCS/2 system disk to /h0/MCS2/.SYS.
------------------------------
Code: 2100F04F
Display: Sequence(Z) : XY data over range.
Used by:
Cause: An error occurred when performing a snap-off sequence check.
Remedy: Edit the file to ensure that the snap-off sequence XY coordinates are within range.
------------------------------