Code: 1D00C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D00C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D00C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D00D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D00D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D00E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D00F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D010002
Display:
Used by:
第 1235 页
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D010003
Display: 1D010003
Used by:
Cause: The X length is too long.
Remedy: Check the length of the part.
------------------------------
Code: 1D010004
Display: 1D010004
Used by:
Cause: The X length is too long.
Remedy: Check the length of the part.
------------------------------
Code: 1D010005
Display: 1D010005
Used by:
Cause: The Y length is too short.
Remedy: Check the length of the part.
------------------------------
Code: 1D010006
Display: 1D010006
Used by:
Cause: The Y length is too short.
Remedy: Check the length of the part.
------------------------------
Code: 1D010007
Display: 1D010007
Used by:
Cause: The Y length is too short.
Remedy: Check the length of the part.
------------------------------
Code: 1D010008
Display: 1D010008
Used by:
Cause: The Y length is inappropriate. (Too long or too short)
Remedy: Check the length of the part.
------------------------------
Code: 1D010009
Display: 1D010009
Used by:
Cause: The image was not read correctly. Protrusions and indentations on the upper and lower edges
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000A
Display: 1D01000A
Used by:
Cause: The image was not read correctly. Protrusions and indentations on the upper and lower edges
第 1236 页
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000B
Display: 1D01000B
Used by:
Cause: The X length is too long.
Remedy: Check the length of the part.
------------------------------
Code: 1D01000C
Display: 1D01000C
Used by:
Cause: The X length is inappropriate. (Too long or too short)
Remedy: Check the length of the part.
------------------------------
Code: 1D01000D
Display: 1D01000D
Used by:
Cause: The image was not read correctly. Protrusions and indentations on the upper and lower edges
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000E
Display: 1D01000E
Used by:
Cause: The image was not read correctly. Protrusions and indentations on the upper and lower edges
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000F
Display: 1D01000F
Used by:
Cause: The Y length is too short.
Remedy: Check the length of the part.
------------------------------
Code: 1D010010
Display: 1D010010
Used by:
Cause: (4 digit decimal code) : The part is tilted at an angle exceeding 45 deg..
(hexadecimal code): The Y direction dimension is too short.
Remedy: (4 digit decimal code): Check that the nozzle is clean, and that the part is clean. Check that the
correct part is being picked. (hexadecimal code): Check the length of the part.
------------------------------
Code: 1D010011
Display: 1D010011
Used by:
Cause: (4 digit decimal code): The X length is too short. (hexadecimal code): The Y length is too short.
Remedy: (4 digit decimal code): Check the part length. Check that Part data is accurate to within +-20%.