FUJI错误代码查询.pdf - 第1938页
Remedy: If doing a direct start-up, check the start-up option. ------------------------------ Code: 21007501 Display: Illegal parameter Used by: Cause: The startup parameter is illegal. Remedy: If doing a direct start-up…
Part data.
Remedy:
------------------------------
Code: 2100743F
Display: "S_nozzle travel for station over"
Used by:
Cause: This is a warning. A component that uses an S-size nozzle has exceeded the station limit. This
component will be allocated to the other station.
Remedy: If the program is executed as is, the stations will be forced to exchange the nozzle. This warning
can be avoided by changing the fixed nozzle size.
------------------------------
Code: 21007440
Display: "M_nozzle travel for station over"
Used by:
Cause: This is a warning. A component that uses an M-size nozzle has exceeded the station limit. This
component will be allocated to the other station.
Remedy: If the program is executed as is, the stations will be forced to exchange the nozzle. This warning
can be avoided by changing the fixed nozzle size.
------------------------------
Code: 21007441
Display: "Not PST file"
Used by:
Cause: A file that has been specified as a PST file does not have the ".pst" extension.
Remedy: Specify a PST file as the permanent set table.
------------------------------
Code: 21007442
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007443
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007444
Display: "Undefined cartridge name for device in PT file"
Used by:
Cause: The feeder type cannot be determined, because the feeder type has not been entered in the device
comment field of the PST file. The feeder type will be determined based on the Part data
Remedy: Use the editor to edit the PST file, and enter a feeder type in the "Device_name" parameter for the
device number in question.
------------------------------
Code: 21007500
Display: Illegal Parameter option
Used by:
Cause: The specified option is illegal.
第 1937 页
Remedy: If doing a direct start-up, check the start-up option.
------------------------------
Code: 21007501
Display: Illegal parameter
Used by:
Cause: The startup parameter is illegal.
Remedy: If doing a direct start-up, check the start-up parameters.
------------------------------
Code: 21007502
Display: Illegal base position (ST1)
Used by:
Cause: The reference device is out of range.
Remedy: Station 1 includes devices 1~35. Specify within this range.
------------------------------
Code: 21007503
Display: Illegal base position (ST2)
Used by:
Cause: The reference device is out of range.
Remedy: Station 1 includes devices 41~45. Specify within this range.
------------------------------
Code: 21007504
Display: Illegal base position (TRAY_R)
Used by:
Cause: The reference device is out of range.
Remedy: TRAY_R includes devices 101~110. Specify within this range.
------------------------------
Code: 21007505
Display: Illegal base position (TRAY_L)
Used by:
Cause: The reference device is out of range.
Remedy: TRAY_L includes devices 111~120. Specify within this range.
------------------------------
Code: 21007506
Display: Message file read error
Used by:
Cause: Unable to read the message file.
Remedy: Re-boot MCS.
------------------------------
Code: 21007507
Display: Read pipe create error
Used by:
Cause: Unable to create the pipe.
Remedy: Re-install the software.
------------------------------
Code: 21007508
Display: Write pipe create error
Used by:
Cause: Unable to create the pipe.
Remedy: Re-install the software.
------------------------------
Code: 21007509
第 1938 页
Display: CRT event link error
Used by:
Cause: Unable to link the CRT event.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100750A
Display: MTT file get error
Used by:
Cause: Unable to read the system (MTT) file.
Remedy: Re-install the software.
------------------------------
Code: 2100750B
Display: MTT file not found
Used by:
Cause: MTT file not found.
Remedy: Re-install the software.
------------------------------
Code: 2100750C
Display: MTT file open error
Used by:
Cause: Unable to open the machine type table.
Remedy: Re-install the system.
------------------------------
Code: 2100750D
Display: Memory is full
Used by:
Cause: Unable to allocate memory.
Remedy: Re-boot MCS.
------------------------------
Code: 2100750E
Display: MTT file seek error
Used by:
Cause: Unable to seek the file.
Remedy: Re-install the software.
------------------------------
Code: 2100750F
Display: Production file not found
Used by:
Cause: Unable to find the production program.
Remedy: Check the filename and the file.
------------------------------
Code: 21007510
Display: Production file open error
Used by:
Cause: Unable to open the production file.
Remedy: Check the file.
------------------------------
Code: 21007511
Display: Program machine type unmatched
Used by:
Cause: The production program's machine type is wrong.
第 1939 页