FUJI错误代码查询.pdf - 第295页
Used by: Cause: The stocker is not set so the screen cannot be supplied or received. Remedy: Set the stocker. ------------------------------ Code: 12020417 Display: Used by: Cause: There is a screen in the receiving posi…
Remedy: Check that the screen Y transport can move properly. Check that the retract and advance limit
sensors are inputting correctly.
------------------------------
Code: 12020404
Display:
Used by:
Cause: The Y chuck could not open or close in the specified time.
Remedy: Check that the screen Y transport chuck can open/close correctly. Check that the sensors are
operating correctly.
------------------------------
Code: 12020410
Display:
Used by:
Cause: If the machine is barcode-compatible, screens up to #10 were used properly. If the machine is
barcode-compatible, a screen with the name set in the program does not exist in the stocker.
Remedy:
------------------------------
Code: 12020411
Display:
Used by:
Cause: Even though there is a screen in the backside cleaning position, the screen supply command did
not occur.
Remedy: If the screen is being supplied from the stocker, remove the screen from the backside cleaning
position.
------------------------------
Code: 12020412
Display:
Used by:
Cause: The screen is not in the proper position.
Remedy: Check that there is a screen.
------------------------------
Code: 12020413
Display:
Used by:
Cause: The elevator is in the overtravel position.
Remedy: Inch the elevator away from the overtravel sensor.
------------------------------
Code: 12020414
Display:
Used by:
Cause: The elevator is in the overtravel position.
Remedy: Inch the elevator away from the overtravel sensor.
------------------------------
Code: 12020415
Display:
Used by:
Cause: The screen has left the stocker so the elevator cannot move.
Remedy: Return the screen to its proper position in the elevator.
------------------------------
Code: 12020416
Display:
第 294 页
Used by:
Cause: The stocker is not set so the screen cannot be supplied or received.
Remedy: Set the stocker.
------------------------------
Code: 12020417
Display:
Used by:
Cause: There is a screen in the receiving position so screens cannot be received.
Remedy: Make a space in the stocker so that screens can be received.
------------------------------
Code: 12020420
Display:
Used by:
Cause: The barcode cannot be read.
Remedy: Check the condition of the barcode on the screen.
------------------------------
Code: 12020421
Display:
Used by:
Cause: This error code was caused by the barcode reader.
Remedy: Consult the barcode reader operation manual.
------------------------------
Code: 12020422
Display:
Used by:
Cause: An unknown command was sent to the stocker.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji.
------------------------------
Code: 12020423
Display:
Used by:
Cause: The stocker is in local mode.
Remedy: Put the stocker into online mode.
------------------------------
Code: 12020424
Display:
Used by:
Cause: This error code was caused by the servo amp.
Remedy: Check the stocker elevator servo amp.
------------------------------
Code: 12020425
Display:
Used by:
Cause: The elevator axis has not been zero-set.
Remedy: If the stocker has been started, zero-set it.
------------------------------
Code: 12020426
Display:
Used by:
Cause: If the stocker is at #1, the descend command was received. If it was at #10, the ascend command
第 295 页
was received.
Remedy: If this happens frequently in automatic operation, contact Fuji.
------------------------------
Code: 12020501
Display:
Used by:
Cause: The stocker is in operation mode, so the command cannot be executed.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. Check the command against the machine mode.
------------------------------
Code: 12020502
Display:
Used by:
Cause: The stocker is in monitor mode, so the command cannot be executed.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. Check the command against the machine mode.
------------------------------
Code: 12020503
Display:
Used by:
Cause: The stocker or the user program is in P-ROM mode so the program cannot be transmitted.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. Check that the memory unit's RAM or EEP-ROM unit is not in overwrite protect mode.
------------------------------
Code: 12020504
Display:
Used by:
Cause: Address over/The user program has exceeded the values for all areas. If this problem occurs
frequently, check the stocker ROM version and the machine version, and contact Fuji. Check the program
again.
Remedy:
------------------------------
Code: 1202050B
Display:
Used by:
Cause: The stocker is in program mode, so the command cannot be executed.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. This code is not currently in use.
------------------------------
Code: 1202050C
Display:
Used by:
Cause: The stocker is in debug mode, so the command cannot be executed.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
contact Fuji. Check the command against the machine mode.
------------------------------
Code: 12020510
Display:
Used by:
Cause: A parity error occurred while the upper system link was receiving a command.
Remedy: If this problem occurs frequently, check the stocker ROM version and the machine version, and
第 296 页