FUJI错误代码查询.pdf - 第4826页

员 NXTR:1.请清扫单元的测定面。2.请确认单元的盘部分和本体部分之间没有异物。 ------------------------------ Code: 95C30000 Display: 助焊剂单元倾斜异常 Used by: NXT,AIM Cause: 助焊剂单元倾斜于基准。( 补充编码 ) NXTR:助焊剂单元倾斜于基准。倾斜的公差值: 3点的倾斜小于 200um(最大高度和最低高度的差值)( 补充编码 ) Remedy: …

100%1 / 5282
Used by: NXT,AIM
Cause: 在定位点读取中发生了不良。
可考虑以下的原因。
·相机灯不亮
·在定位点上有元件等异物
·被搬运轨道导轨遮住
·定位点缺损
( 补充编码 00XXYY00
XX:平台号码
01:平台1
02:平台2
YY:料盘供料器种类·位置
01:料盘供料器MA
02:料盘供料器MB
03:料盘供料器MC
04:料盘供料器LA
05:料盘供料器LB )
Remedy: 如果影像暗淡时
1.请确认相机灯是否亮灯。
2.请确认触发电路。
如果影像不清晰时
1.请确认定位点是否缺损。
2.请清扫相机镜头。
------------------------------
Code: 95C00000
Display: An internal processing error occurred
Used by: NXT,AIM
Cause: The process was discontinued due to an illegal process within the system.
( Additional )
Remedy: If this does not resolve the problem, acquire trace data from the machine under the conditions in
which the error occurs, and contact your Fuji representative.Turn off the main switch and restart the
machine.
------------------------------
Code: 95C10000
Display: 在Dip动作的加压力控制中发生了紧急停止。
Used by: NXT,AIM
Cause: 由于在使用加压力控制下降Z轴时发生了紧急停止,Z轴的下降动作停止了。
根据停止位置,元件一直浸没在Flux槽内,Flux有可能附着在吸嘴上。
另外,也可考虑元件的落下。
(补充编码)
Remedy: 如果元件落到Flux槽内,请取除元件后重新开始生产。
同时请确认Flux是否附着在吸嘴上。
如果附着时,成为缺元件或误贴装的原因,因此请清扫。
如果没有问题,就这样请重新开始生产。
------------------------------
Code: 95C20000
Display: 助焊剂单元高度异常
Used by: NXT,AIM
Cause: 助焊剂单元的高度偏离基准。( 补充编码 ) NXTR:助焊剂单元的高度偏离基准。高度的公差值:测定的3点
都在盘边缘的基准高度(Z0-1mm)±300um以内。(补充编码)
Remedy: 1.请清扫单元的测定面 2.不能解决时,请收集发生错误时的跟踪数据并联系本公司的代理店或售后服务人
第 4825 页
员 NXTR:1.请清扫单元的测定面。2.请确认单元的盘部分和本体部分之间没有异物。
------------------------------
Code: 95C30000
Display: 助焊剂单元倾斜异常
Used by: NXT,AIM
Cause: 助焊剂单元倾斜于基准。( 补充编码 ) NXTR:助焊剂单元倾斜于基准。倾斜的公差值: 3点的倾斜小于
200um(最大高度和最低高度的差值)( 补充编码 )
Remedy: 1.请清扫单元的测定面 2.请确认单元的盘部分和本体部分之间没有异物 3.不能解决时,请收集发生错
误时的跟踪数据并联系本公司的代理店或售后服务人员 NXTR:1.请清扫单元的测定面。2.请确认单元的盘部分和
本体部分之间没有异物。
------------------------------
Code: 95C40000
Display: 阻焊剂单元测定时发生XY机械手异常
Used by: NXT,AIM
Cause: NXTR:助焊剂单元测定过程中发生XY轴异常。(补充编码)
Remedy: NXTR:关于异常的详细内容请参照单元错误。
------------------------------
Code: 95C50000
Display: 助焊剂单元测定时发生工作头异常
Used by: NXT,AIM
Cause: NXTR:助焊剂单元测定过程中发生工作头异常。(补充编码)
Remedy: NXTR:关于异常的详细内容请参照单元错误。
------------------------------
Code: 95C60000
Display: 助焊剂单元测定时发生工作头异常
Used by: NXT,AIM
Cause: NXTR:助焊剂单元测定过程中发生工作头异常。(补充编码)
Remedy: NXTR:关于异常的详细内容请参照单元错误。
------------------------------
Code: 95C70000
Display: 助焊剂单元测定的应用程序异常
Used by: NXT,AIM
Cause: NXTR:在系统内发生了不正确的处理,所以处理无法继续进行。(补充编码)
Remedy: NXTR:请重启机器。
------------------------------
Code: 95C80000
Display: 助焊剂单元测定时发生Zs轴异常
Used by: NXT,AIM
Cause: NXTR:助焊剂单元测定过程中发生了Zs轴异常。(补充编码)
Remedy: NXTR:关于异常的详细内容请参照单元错误。
------------------------------
Code: 95D00000
Display: An internal processing error occurred
Used by: NXT,AIM
Cause: The process was discontinued due to an illegal process within the system.
( Additional )
Remedy: If this does not resolve the problem, acquire trace data from the machine under the conditions in
which the error occurs, and contact your Fuji representative.Turn off the main switch and restart the
machine.
------------------------------
Code: 95D10000
第 4826 页
Display: 测出了IP地址的重复
Used by: NXT,AIM
Cause: 测出了与机器的IP地址重复的IP地址。
(补充编码)
Remedy: 1.请呼叫网络管理者。
2.请变更IP地址使得IP地址不重复。
3.实施对策后,请关闭主电源开关后重新打开,重新启动机器。
------------------------------
Code: 95E00000
Display: 内部处理异常( 吸取位置确认2 )
Used by: NXT,AIM
Cause: 系统内发生了处理异常。
( 补充编码 )
Remedy: 对不起麻烦您获取错误发生时的跟踪数据,连同错误发生时的操作步骤一起与弊公司Support联系。为了重
新开始运转,请重新接通总电源开关。
------------------------------
Code: 95E10000
Display: 所指定的料站位置是不能够进行吸取位置测定的区域
Used by: NXT,AIM
Cause: 进行吸取位置确认的料站位置由于在XY机械手单元的移动范围外,而不能执行吸取位置确认。
( 补充编码 无 )
Remedy: 1.对于处于不能够进行测定的区域的料站,请不要进行吸取位置确认。
2.对于XY机械手的移动范围外的轴,请确认单元错误编码。
3.对于不能进行吸取位置确认的料站,只能进行料站修正值的设定。
------------------------------
Code: 95E20000
Display: 由于工作头组合异常,因此吸取位置确认指令无法被执行。
Used by: NXT,AIM
Cause: 对于现在所连接的工作头的组合,无法执行料盘单元L的吸取位置确认指令。
( 补充编码 )
Remedy: 请将工作头更换成想要进行吸取位置确认的Job中所指定的工作头的组合后,执行指令。
下记的工作头的组合无法执行料盘单元L的吸取位置确认的指令。
【限制工作头的列表】
H12S/H12S
H08/H08
------------------------------
Code: 95E30000
Display: 吸取位置确认指令因为料盘元件干涉检查异常而不能执行
Used by: NXT,AIM
Cause: 吸取位置确认指令因为料盘元件和工作头有干涉的可能性而不能执行。( 补充编码
),NXT,AIMEX,KSD,NEO,MWU12i,SNC,NXTP
Remedy: 请使用以下1个方法解决问题后,再次执行。
① 请在更换成生产Job中使用的工作头后,执行指令。
② 进行了叠放时,请将料盘元件的高度变更到小于【干涉高度一览】的「料盘高度限制」,然后执行指令。
【干涉高度一览】
料盘高度限制
F04/G04/G04F 25.5mm
H12/H12S/H12HS/V12 22mm
H0828mm
其他的工作头32mm
------------------------------
第 4827 页