FUJI错误代码查询.pdf - 第861页
------------------------------ Code: 121???21 Display: Coplanarity error(NP2,QP3) Used by: QP242,NP2,QP3 Cause: A command sequence error occurred. The command could not be executed at the LLL board. Remedy: Restart the s…
Cause: There are no leads on the part where a lead coplanarity check is occurring.
Remedy: Do not perform a lead coplanarity check for parts without leads. Verify that the part data
(number of leads) is set correctly.
------------------------------
Code: 121???0C
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an error or a time up condition occurred when the LLL board linearity calculation
command was executed.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???0D
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Either an internal processing error or a time up condition occurred when the LLL board linearity
calculation command was executed.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???0E
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: An error occurred when the linearity calculation result was received or checked. Either a
communication time up condition occurred, or no leads were detected, resulting in no calculation result.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off. Also verify that the part size is correct.
------------------------------
Code: 121???0F
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: An attempt to obtain linearity calculation results from the LLL board ended in failure. Either a
communication time up occurred, or the lead bend amount exceed the permissible range.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???10
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: An error occurred when the coplanarity calculation result was received or checked. A
communication time up occurred.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
------------------------------
Code: 121???11
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: An attempt to obtain coplanarity calculation results from the LLL board ended in failure. Either a
communication time up occurred, or the lead bend amount exceed the permissible range.
Remedy: If the LLL baud rate is less than 9600bps, set it to 9600bps or higher. (Time up) If the problem
continues, turn the power off.
第 860 页
------------------------------
Code: 121???21
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: A command sequence error occurred. The command could not be executed at the LLL board.
Remedy: Restart the system, and repeat the operation from the beginning.
------------------------------
Code: 121???22
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Insufficient data error. LLL board calculation ended in failure due to insufficient data. Lead
measurement was not performed, and no pulse was received from the encoder. A coplanarity calculation
was attempted after scanning 1 side.
Remedy: Set the Lead-Length (in part data) as accurately as possible. Increase the Scan Offset to permit
measurement of the full length of the lead. Lead coplanarity checks are possible for SOIC or QFP parts.
------------------------------
Code: 121???23
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Parameter error. The received data is invalid for the LLL..
Remedy: Check the Coplanarity item in part data.
------------------------------
Code: 121???24
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Invalid command. The attempted command is invalid for the LLL..
Remedy: Execute a reset start.
------------------------------
Code: 121???30
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Serial communication "receive overrun" error.
Remedy: Restart the system and repeat the operation from the beginning.
------------------------------
Code: 121???31
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Serial communication "parity" error.
Remedy: Restart the system and repeat the operation from the beginning.
------------------------------
Code: 121???32
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Serial communication "framing" error.
Remedy: Restart the system and repeat the operation from the beginning.
------------------------------
Code: 121???40
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Communication with "Sensor 0 EEPROM Readback Error sensor 0" is not occurring. Sensor
cable is severed or disconnected.
第 861 页
Remedy: Check the sensor cable continuity, and replace the cable if necessary.
------------------------------
Code: 121???42
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Communication with "Sensor Synchronization Error sensor 0" is not occurring. Sensor cable is
severed or disconnected.
Remedy: Check the sensor cable continuity, and replace the cable if necessary.
------------------------------
Code: 121???50
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: "Expecting FIFO Empty VME" board failure.
Remedy: Turn the power off and execute a reset start.
------------------------------
Code: 121???60
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Laser beam was uninterrupted at the wrong point, or was never interrupted.
Remedy: Check the sensor mount position and the lead measurement position. If this occurs during lead
measurement, verify that the part data "Lead Length" is set as accurately as possible. Increase the
"lead_offset" for the "Coplanarity" item in part data to ensure that the full length of the lead is measured.
------------------------------
Code: 121???61
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Laser beam was interrupted at the wrong point, or is still interrupted.
Remedy: Verify that no foreign matter or parts are adhering to the sensor. Verify that the body is not
being measured instead of the lead during lead measurements.
------------------------------
Code: 121???70
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Coplanarity calculation results indicate a lead height above the "Coplanarity Tolerance" height
(part data).
Remedy: Check for raised part leads. Verify that the "Coplanarity Tolerance" value (part data) is not too
small.
The coplanarity check result can be viewed at the [Coplanarity] screen. (QP3)
However, only the most recently performed check for each holder can be viewed. (QP3)
The [Coplanarity] screen can be reached through the following path: [Main] -[Maintenance] -
[Coplanarity]. (QP3)
------------------------------
Code: 121???71
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: Linearity calculation results indicate a lead which is outside the "Linear Tolerance" plane (part
data).
Remedy: Check for bent part leads. Verify that the "Linear Tolerance" value (part data) is not too small.
The coplanarity check result can be viewed at the [Coplanarity] screen. (QP3)
However, only the most recently performed check for each holder can be viewed. (QP3)
The [Coplanarity] screen can be reached through the following path: [Main] -[Maintenance] -