FUJI错误代码查询.pdf - 第1936页

Display: PT file device station range over Used by: Cause: The Permanent Set Table device station is out of range. Remedy: Check the PST file device number. ------------------------------ Code: 21007438 Display: Input pr…

100%1 / 5282
Remedy: Check Part data.
------------------------------
Code: 2100742F
Display: Skip device can not mount
Used by:
Cause: Unable to mount skip device.
Remedy: This is a warning. There are too many devices, so the skip device cannot be mounted.
------------------------------
Code: 21007430
Display: Next device can not mount
Used by:
Cause: Unable to mount next device.
Remedy: This is a warning. There are too many devices, so the next device cannot be mounted.
------------------------------
Code: 21007431
Display: Can not used Tray type device
Used by:
Cause: Unable to use the tray type.
Remedy: Check Part data.
------------------------------
Code: 21007432
Display: Can not used Cartride type
Used by:
Cause: An unusable feeder type has been specified.
Remedy: Check Part data.
------------------------------
Code: 21007433
Display: No entry Machine type
Used by:
Cause: The input machine type is unsupported.
Remedy: Check the file. Upgrade the version if necessary.
------------------------------
Code: 21007434
Display: Program machine type unmatched
Used by:
Cause: The input file is not an IP2 program.
Remedy: Check the file.
------------------------------
Code: 21007435
Display: No entry Tray type
Used by:
Cause: The specified tray type cannot be used.
Remedy: Check Part data.
------------------------------
Code: 21007436
Display: New prodction file has no sequence data
Used by:
Cause: The new production program has no sequence data.
Remedy: Check the program's sequence data.
------------------------------
Code: 21007437
第 1935 页
Display: PT file device station range over
Used by:
Cause: The Permanent Set Table device station is out of range.
Remedy: Check the PST file device number.
------------------------------
Code: 21007438
Display: Input program file name is too long
Used by:
Cause: Input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007439
Display: Output program file name is too long.
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 2100743A
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 2100743B
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 2100743C
Display: Can't used Station_No. to Tray_type_device
Used by:
Cause: Tray parts have been specified at non-tray device numbers.
Remedy: If the device number is a fixed device, check that the device locations at the input program are
correct. If the device number is in the Permanent Set Table, check that the device locations in the
Permanent Set Table are correct. If the device locations are in the base program, check that the device
locations in the base program are correct.
------------------------------
Code: 2100743D
Display: Status does not Tray_type_device
Used by:
Cause: Tray parts have been specified for non-tray device positions.
Remedy: If the device number is a fixed device, check that the device locations at the input program are
correct. If the device number is in the Permanent Set Table, check that the device locations in the
Permanent Set Table are correct. If the device locations are in the base program, check that the device
locations in the base program are correct.
------------------------------
Code: 2100743E
Display: "No entry Machine name"
Used by:
Cause: A machine name has not been entered in the "Type" parameter in the "Sep_data" section of the
第 1936 页
Part data.
Remedy:
------------------------------
Code: 2100743F
Display: "S_nozzle travel for station over"
Used by:
Cause: This is a warning. A component that uses an S-size nozzle has exceeded the station limit. This
component will be allocated to the other station.
Remedy: If the program is executed as is, the stations will be forced to exchange the nozzle. This warning
can be avoided by changing the fixed nozzle size.
------------------------------
Code: 21007440
Display: "M_nozzle travel for station over"
Used by:
Cause: This is a warning. A component that uses an M-size nozzle has exceeded the station limit. This
component will be allocated to the other station.
Remedy: If the program is executed as is, the stations will be forced to exchange the nozzle. This warning
can be avoided by changing the fixed nozzle size.
------------------------------
Code: 21007441
Display: "Not PST file"
Used by:
Cause: A file that has been specified as a PST file does not have the ".pst" extension.
Remedy: Specify a PST file as the permanent set table.
------------------------------
Code: 21007442
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007443
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007444
Display: "Undefined cartridge name for device in PT file"
Used by:
Cause: The feeder type cannot be determined, because the feeder type has not been entered in the device
comment field of the PST file. The feeder type will be determined based on the Part data
Remedy: Use the editor to edit the PST file, and enter a feeder type in the "Device_name" parameter for the
device number in question.
------------------------------
Code: 21007500
Display: Illegal Parameter option
Used by:
Cause: The specified option is illegal.
第 1937 页