FUJI错误代码查询.pdf - 第2036页

Used by: Cause: An error occurred when creating the work file for generating the offset table. Remedy: Re-execute the analyzer at the UCI screen. If this does not work, execute the analyzer after completing the operation…

100%1 / 5282
------------------------------
Code: 2100B1C1
Display: Coplanarity error (MC) file read error.
Used by:
Cause: Data could not be read from the coplanarity check device error analysis file.
Remedy: Re-execute the Analyzer.
------------------------------
Code: 2100B1C2
Display: Coplanarity error (MC) file write error.
Used by:
Cause: Data could not be written to the coplanarity check device error analysis file.
Remedy: Abort the operation presently being executed, using the [ESC] key for example, and then re-
execute the Analyzer. Alternatively shorten the time frame being analyzed.
------------------------------
Code: 2100B1C3
Display: Coplanarity eval file load error.
Used by:
Cause: Data could not be read from the analyzed coplanarity check result file.
Remedy: Abort the operation presently being executed, using the [ESC] key for example, and select "NO"
to end at the Analyzer screen. Return to the UCI screen and re-execute the Analyzer. If the problem
recurs, reset the MCS.
------------------------------
Code: 2100B1C4
Display: Coplanarity eval file not found.
Used by:
Cause: The analyzed coplanarity check result file could not be opened.
Remedy: Abort the operation presently being executed, using the [ESC] key for example, and select "NO"
to end at the Analyzer screen. Return to the UCI screen and re-execute the Analyzer. If the problem
recurs, reset the MCS.
------------------------------
Code: 2100B1C5
Display: Mainte coplanarity error work file create error.
Used by:
Cause: An error file could not be created from the coplanarity check work file.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer. If the error recurs,
reset the MCS.
------------------------------
Code: 2100B1C8
Display: Mainte coplanarity error work file write error.
Used by:
Cause: Data could not be written to the error file created from the coplanarity check work file.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1C9
Display: Coplanarity error total file write error.
Used by:
Cause: Data could not be written to the file containing the total number of coplanarity check errors
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1CA
Display: Offset table work data file create error.
第 2035 页
Used by:
Cause: An error occurred when creating the work file for generating the offset table.
Remedy: Re-execute the analyzer at the UCI screen. If this does not work, execute the analyzer after
completing the operation presently being executed. Alternatively, shorten the time frame being analyzed.
If this does not work, reboot the MCS.
------------------------------
Code: 2100B1CB
Display: Offset table work data file open error.
Used by:
Cause: An error occurred when the work file for generating the offset table was opened.
Remedy: Select "NO" to end the operation presently being executed. Return to the UCI screen and re-
execute the analyzer.
------------------------------
Code: 2100B1CC
Display: Offset table work data file read error.
Used by:
Cause: The work file for generating the offset table could not be read.
Remedy: Select "NO" to end the operation presently being executed. Return to the UCI screen and re-
execute the analyzer.
------------------------------
Code: 2100B1CD
Display: Offset table work data file write error.
Used by:
Cause: Data could not be written to the work file for generating the offset table.
Remedy: End the operation presently being executed, return to the UCI screen, and re-execute the
analyzer. Alternatively, shorten the time frame being analyzed. If this does not work, reboot the MCS.
------------------------------
Code: 2100B200
Display: change path error - press [ESC] key
Used by:
Cause: There was a path change error.
Remedy: Re-execute the function.
------------------------------
Code: 2100B201
Display: loglist pipe open error - press [ESC] key
Used by:
Cause: Unable to open the loglist.
Remedy: Re-execute the function. If the error recurs, reset the system.
------------------------------
Code: 2100B204
Display: can't open monitor read pipe
Used by:
Cause: Unable to open the monitor read pipe.
Remedy: Reset the system.
------------------------------
Code: 2100B205
Display: CTR event link error - press [ESC] key
Used by:
Cause: Unable to link the CRT event.
Remedy: Re-execute the function. If the error recurs, reset the system.
------------------------------
第 2036 页
Code: 2100B206
Display: Line Descriptor read error - press [ESC] key
Used by:
Cause: Unable to read the line descriptor.
Remedy: Check the line descriptor file.
------------------------------
Code: 2100B207
Display: can't create setting file
Used by:
Cause: Unable to create the setting file.
Remedy: Re-execute the function from the UCI menu.
------------------------------
Code: 2100B208
Display: can't save setting data
Used by:
Cause: Unable to save the setting file.
Remedy: Re-execute the function.
------------------------------
Code: 2100B209
Display: Can't set loglist start time to the future
Used by:
Cause: The loglist start time is set to the future.
Remedy: Set the correct time and date.
------------------------------
Code: 2100B20A
Display: Can't set loglist end time prior to the start time
Used by:
Cause: The loglist start time is set prior to the end time.
Remedy: Set a correct time and date.
------------------------------
Code: 2100B20B
Display: Line name not found in Line Descriptor
Used by:
Cause: The line name was not found in the line descriptor.
Remedy: Input the line name into the line descriptor.
------------------------------
Code: 2100B20C
Display: Machine nickname not found in specified line
Used by:
Cause: The machine nickname was not found in the line descriptor.
Remedy: Input the machine nickname into the line descriptor.
------------------------------
Code: 2100B20D
Display: Machine nickname not found in specified line
Used by:
Cause: The machine nickname was not found in the line descriptor.
Remedy: Input the machine nickname in the line descriptor.
------------------------------
Code: 2100B20E
Display: Program name not found
Used by:
第 2037 页