FUJI错误代码查询.pdf - 第615页
Code: 12063015 Display: "Screen Error Print Pos" Used by: GP551,GP6 Cause: Stencil transport was not possible because the stencil at the print position is not set correctly. (GSP5) The stencil at the print posi…
Remedy: Check that the parts are correct.
------------------------------
Code: 1206300D
Display: Check Name Length
Used by:
Cause: The screen name is too long.
Remedy: Screen name must not exceed 20 characters. Check the screen name heading in the production
program.
------------------------------
Code: 1206300E
Display: cleaner not at origin
Used by: GSP5,GP551,GP6
Cause: The cleaner position is unknown.
Remedy: Return the cleaner to the origin position.
------------------------------
Code: 1206300F
Display: not enough solvent
Used by: GSP5
Cause: There is no cleaning fluid.
Remedy: Add cleaning fluid.
------------------------------
Code: 12063010
Display:
Used by: GP551,GP6
Cause: Ultrasonic oscillator alarm at the cleaner.
Remedy: Check that the power is on. If this error occurs frequently replace the oscillator.
------------------------------
Code: 12063011
Display:
Used by: GSP5
Cause: The solder supply/stop command was issued, but operation was not confirmed.
Remedy: The solder supply machine communication line is probably cut. Check the line.
------------------------------
Code: 12063012
Display:
Used by: GSP5
Cause: Operation could not be carried out because the solder supply machine was incorrectly positioned.
Remedy: After returning the solder supply machine to its origin position, restart operation.
------------------------------
Code: 12063013
Display: "Screen at rear cleaning position"
Used by:
Cause: The storage command cannot be executed because there is a screen at the rear cleaning position.
Remedy: Re-execute the storage command after removing the screen from the rear cleaning position.
------------------------------
Code: 12063014
Display:
Used by:
Cause: There is no screen in the backside cleaning position so the supply command cannot be executed.
Remedy: Set a screen in the backside cleaning position and execute the command.
------------------------------
第 614 页
Code: 12063015
Display: "Screen Error Print Pos"
Used by: GP551,GP6
Cause: Stencil transport was not possible because the stencil at the print position is not set correctly.
(GSP5) The stencil at the print position is not correctly set. (GP6)
Remedy: Move the stencil that was in the process of being transported, to the proper position. (GSP5)
Set the stencil that is at the print position, in the appropriate position to allow the stencilto be clamped.
This error will occur if the stencil cannot be properly clamped at this time. (GP6)
------------------------------
Code: 12063016
Display:
Used by:
Cause: The screen is not set properly in the backside cleaning position so it cannot be transported.
Remedy: Move the screen to where it can be properly transported.
------------------------------
Code: 12063017
Display: "No Stencil At Print Pos"
Used by: GP6
Cause: Automatic operation could not be started because there was no stencil at the print position. Or a
stencil could not be stored in the stocker.
Remedy: Set a stencil.
------------------------------
Code: 12063018
Display:
Used by:
Cause: The mask receiving unit is ascended.
Remedy: Lower the mask receiving unit.
------------------------------
Code: 12063019
Display:
Used by: GSP5
Cause: Even though the camera station is out, the S-axis wants to move out.
Remedy: Retract the camera station.
------------------------------
Code: 1206301A
Display:
Used by: GSP5
Cause: When the camera station is moving, it interferes with the Y-axis. Alternately, the Y-axis interlock
sensor is not working correctly.
Remedy: Retract the Y-axis so that it does not interfere with the camera station. Also, check the interlock
sensor.
------------------------------
Code: 1206301B
Display:
Used by: GSP5
Cause: When the camera station is moving, it interferes with the S-axis. Alternately, the S-axis interlock
sensor is not working correctly.
Remedy: Retract the S-axis so that it does not interfere with the camera station. Also, check the interlock
sensor.
------------------------------
Code: 1206301C
第 615 页
Display:
Used by: GSP5,GP551,GP6
Cause: When the Y- or Z-axis is moving, it interferes with the board holder. Alternately, the board holder
interlock sensor is not working correctly.
Remedy: Retract the board holder so that it does not interfere with the camera station. Also, check the
interlock sensor.
------------------------------
Code: 1206301D
Display:
Used by: GSP5
Cause: The board and the mask expansion rate exceeds the production program's elongation_limit item.
Remedy: Increase the value of the elongation_limit in the production program or change the mask and
board. Alternately, set elongation_limit to 0 and this item will be disabled.
------------------------------
Code: 1206301E
Display:
Used by: GSP5,GP2,GP3
Cause: The screen position compensation was carried out, but the pulse motor moved more than the
value allowed in the Proper data item Max Limit Position ***.
Remedy: Check the mark coordinates in the program. Adjust the screen frame spacers. Check that the
Proper data item Max Limit Position is not set to 0.
------------------------------
Code: 1206301F
Display:
Used by:
Cause: Process timeout occurred during communication.
Remedy: Contact Fuji if this happens frequently.
------------------------------
Code: 12063020
Display:
Used by:
Cause: The stocker data set signal was output, but no reply was received.
Remedy: Check the wiring. Check that the stocker sequencer is operating correctly.
------------------------------
Code: 12063021
Display:
Used by:
Cause: A command was sent to the stocker communication unit but a response was not received within
the specified time limit.
Remedy: Check the wiring. If this error occurs frequently, check the machine version and the stocker
ROM version, and contact Fuji.
------------------------------
Code: 12063022
Display:
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: Communication could not be carried out with the printing measurement machine.
Remedy: Check the wiring between the terminal and the printing measurement machine.
------------------------------
Code: 12063023
Display:
Used by: GSP5
第 616 页