Code: 2100F009
Display: File load error
Used by:
Cause: The specified file could not be loaded to memory.
Remedy: Re-execute the function. If the error recurs, re-install the software.
------------------------------
Code: 2100F00A
Display: can't load file descriptor on memory
Used by:
Cause: The File Descriptor could not be loaded.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 2100F00B
Display: This check file is not a program
Used by:
Cause: The specified file is not a production program file.
Remedy: Specify the correct file name.
------------------------------
Code: 2100F00C
Display: can't open check table file
Used by:
Cause: The data check table could not be opened.
Remedy: Re-install the software.
------------------------------
Code: 2100F00D
Display: can't read check table data
Used by:
Cause: The data check table could not be read.
Remedy: Re-install the software.
------------------------------
Code: 2100F00E
Display: can't open Lp pipe
Used by:
Cause: The header information data check flag could not be written.
Remedy: Re-boot MCS.
------------------------------
Code: 2100F00F
Display: check flag rewrite error
Used by:
Cause: The data check flag could not be written to the header.
Remedy: Check that the file overwrite protect setting is not on.
------------------------------
Code: 2100F010
Display: Prog info: %s data over range
Used by:
Cause: The **** data in the program data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F011
Display: Prod mode: %s data over range
Used by:
第 2100 页
Cause: The **** data in the production mode data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F012
Display: M/C data: %s over range
Used by:
Cause: The **** data in the machine data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F013
Display: PCB data: %s over range
Used by:
Cause: The **** data in the PCB data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F014
Display: Mark data: %s out of range
Used by:
Cause: The **** data in the mark data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F015
Display: Dev data: %s over range
Used by:
Cause: The **** data in the device data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F016
Display: MB data: %s over range
Used by:
Cause: The **** data in the multi-block offset data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F017
Display: Seq data: %s over range
Used by:
Cause: The **** data in the sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F018
Display: Mark seq: %s over range
Used by:
Cause: The **** data in the fiducial mark reading sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F019
Display: Placing seq: %s over range
Used by:
Cause: The **** data in the placing sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
第 2101 页
Code: 2100F01A
Display: This program is over sequence
Used by:
Cause: The length of the sequence data exceeds the fixed limit.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01B
Display: This program is over device
Used by:
Cause: The length of the device data exceeds the fixed limit.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01C
Display: Duplicate mark number
Used by:
Cause: A fiducial number appears more than once in the sequence data.
Remedy: Contact Fuji.
------------------------------
Code: 2100F01D
Display: This sequence should be set before compare Mark seq
Used by:
Cause: A placing sequence appears before the mark reading sequence to which it refers in the sequence
data.
Remedy: Correct the position of the fiducial mark reading sequence in the sequence data.
------------------------------
Code: 2100F01E
Display: Duplicate mark number on block 0
Used by:
Cause: The mark number in the Block 0 fiducial mark sequence appears again somewhere else in the
sequence data.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F01F
Display: Mark seq. on block0 should be set before compare seq
Used by:
Cause: The fiducial mark sequences in the Block 0 must appear before all other sequence data (except
the Block 0 block-skip sequences).
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F020
Display: Blk. skip seq: %s data over range
Used by:
Cause: The **** data in the block-skip sequence data is out of range.
Remedy: Correct the appropriate data.
------------------------------
Code: 2100F021
Display: Blk. skip seq. should be set before the others
Used by:
Cause: The block-skip sequences must appear before all other sequence data (except the block 0 fiducial
mark sequences).
Remedy: Place the block skip sequences in front of all others (except the block 0 fiducial mark