Used by: Cause: The part cannot be picked. Remedy: Replenish the part supply. ------------------------------ Code: 1D080003 Display: Used by: Cause: An image cannot be taken by vision processing. The part is too large. R…
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D06C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D06C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D06D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D06D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D06E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D06F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D080001
Display:
Used by:
Cause: All the necessary Part data has not been entered.
Remedy: Enter the necessary data.
------------------------------
Code: 1D080002
Display:
第 1316 页
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D080003
Display:
Used by:
Cause: An image cannot be taken by vision processing. The part is too large.
Remedy: Check the camera, vision processing board, cable and focus. Check the part. The lead has to
have a certain thickness to be detected. If the lead thickness is not within +-50% of the thickness set in
Part data this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080004
Display:
Used by:
Cause: The part lead cannot be found.
Remedy: Check that the lead exists, and check the thickness of the lead. Check the part. The lead has to
have a certain thickness to be detected. If the lead thickness is not within +-50% of the thickness set in
Part data this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080005
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part data this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D080006
Display:
Used by:
Cause: No leads can be found.
Remedy: Check whether the lead exists, and check the orientation of the parts when they are fed to the
machine. The lead has to have a certain thickness to be detected. If the lead thickness is not within +-
50% of the thickness set in Part dat this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080007
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part data this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D080008
Display:
Used by:
Cause: The lead pitch is too wide.
Remedy: Check the lead pitch, and check the orientation of the parts when they are fed to the machine.
The lead has to have a certain thickness to be detected. If the lead thickness is not within +-50% of the
thickness set in Part dat this error can occur. Check the part lead and the CCD level.
第 1317 页
------------------------------
Code: 1D080009
Display:
Used by:
Cause: The lead is missing.
Remedy: Check the number of leads, and check the orientation of the parts when they are fed to the
machine. The lead has to have a certain thickness to be detected. If the lead thickness is not within +-
50% of the thickness set in Part dat this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D08000B
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000C
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000D
Display:
Used by:
Cause: The lead width is too long.
Remedy: Check the length of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000F
Display:
Used by:
Cause: Processing error.
Remedy: Check the part shape, and check whether or not the part exists.
------------------------------
Code: 1D080010
Display:
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the number of leads on the part. The lead has to have a certain
thickness to be detected. If the lead thickness is not within +-50% of the thickness set in Part dat this
error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080011
Display:
Used by:
Cause: The part tilt is too large.
第 1318 页