Code: 12066905 Display: abolished. Used by: QP122 Cause: abolished. Remedy: abolished. ------------------------------ Code: 12066906 Display: abolished. Used by: QP122 Cause: abolished. Remedy: abolished. ---------------…
causing this error (almost the same as error 1206681D). This especially occurs when the index motion
type is changed with the retransmission of the program.
Remedy: To avoid parts wastage or double parts placement of a part which is in the machine, the index
motion system cannot be changed. Return to the prior index motion setup or,refer to error 1206681D.
------------------------------
Code: 1206681F
Display: DATA LOGIC ERROR [1206681F]
Used by: QP132
Cause: After restarting automatic operation, a program name which differs from the program name
before the machine stopped, is registered in the pallet ID of the pallet at the in-conveyor.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066820
Display: Family condition error
Used by: QP132
Cause: Wrong family condition.
Remedy: Check the index motion type, board width, rotation format, and nozzle configuration, etc.
------------------------------
Code: 12066901
Display: Out-manipulator interlock error.
Used by: QP132
Cause: The in-manipulator came away from its upper limit (X5A: PCB LD UPCHK) while the axes
(MX/MY/SS) were in motion. Alternatively, the axes (MX/MY/SS) were instructed to move when the in-
manipulator was not at its upper limit.
Remedy: Check the upper limit sensor for the in-manipulator.
------------------------------
Code: 12066902
Display: Out-manipulator interlock error.
Used by: QP132
Cause: The out-manipulator came away from its upper limit (X7A: PCB UL UPCHK) while the axes
(PO/SS) were in motion. Alternatively, the axes (PO/SS) were instructed to move when the out-
manipulator was not at its upper limit.
Remedy: Check the upper limit sensor for the out-manipulator.
------------------------------
Code: 12066903
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066904
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
第 658 页
Code: 12066905
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066906
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066907
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066908
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 12066909
Display: abolished.
Used by: QP122
Cause: abolished.
Remedy: abolished.
------------------------------
Code: 1206690A
Display: Parts supply unit error.
Used by: NP2,QP3
Cause: Parts supply unit error.
Remedy: If the parts supply unit is in position at the removable supply side of the machine, select the
[Power On] and [Power Off] commands on the [Parts Stage] screen, and then select the [Confirmation]
command. If the parts supply unit is not attached, set it in position at the machine. For the fixed supply
side, reboot the machine.
------------------------------
Code: 1206690B
Display: PFU Clamp Error [1206690B]
Used by: QP132
Cause: During automatic operation, the PFU's X030-X033: PFU? CLP OK turned OFF
Remedy: Check that the PFU settings are correct.
------------------------------
Code: 1206690C
Display: PFU Clamp Error [1206690C]
Used by: QP132
Cause: The PFU's clamping operation (X034-X03A: PFU? CLP) did not finish in the given time.
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
第 659 页
Code: 1206690D
Display: PFU Unclamp Error [1206690D]
Used by: QP132
Cause: The PFU's unclamping operation (X035-X03B: PFU? UNCLP) did not finish in the given time.
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 12066A00
Display: ID_GET_PAGE_ERR
LD_ERR 12066A00
Used by: QP132
Cause: The data carrier page data could not be read.
Remedy: Make sure that circulation has been carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A01
Display: ID_TRN_MDL_ERR
LD_ERR 12066A01
Used by: QP132
Cause: There was a communication failure with the command that controls the number of write times.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A02
Display: ID_PAGE_OVER_ERR
LD_ERR 12066A02
Used by:
Cause: The number of data carrier write times has been exceeded.
Remedy: Replace the pallet data carrier.
------------------------------
Code: 12066A03
Display: ID_MDL_RESP_ERR
LD_ERR 12066A03
Used by: QP132
Cause: There was an error with the response from the command that controls the number of write times.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A04
Display: ID_READ_DATA_ERR
LD_ERR 12066A04
Used by: QP132
Cause: The first page of data of the data carrier could not be read.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A05
Display: ID_COPY_DATA_ERR