FUJI错误代码查询.pdf - 第834页

carrier. Care should be taken as the parts may become dislodged. ------------------------------ Code: 1207E?6F Display: "SCU? (PMC?, ICM) Error Code:********" "Pocket unclamping error" Used by: QP201 …

100%1 / 5282
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check connection between the LLL board and the sensor.
Check the cables.(encoder cable etc.)
------------------------------
Code: 1207E?6A
Display: "SCU? (PMC?, ICM) Error Code:********"
"Failed to rec Y calib data"
Used by: QP242
Cause: Failed to receive Y-axis calibration data from the LLL.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check connection between the LLL board and the sensor.
Check the cables.(encoder cable etc.)
------------------------------
Code: 1207E?6B
Display: "SCU? (PMC?, ICM) Error Code:********"
"Spring clip dislodged"
Used by: QP203
Cause: The clip was partially or completely dislodged from the FOL carrier. The question marks (?)
represent the module number. The asterisks (***) represent the error code.
Remedy: Check that the clips are being correctly placed, and that they are securely in position on the
carrier. Care should be taken as the clips may become dislodged.
------------------------------
Code: 1207E?6C
Display: "SCU? (PMC?, ICM) Error Code:********"
"Nozzle station not lowered"
Used by: QP242
Cause: The nozzle station is not at its lowered position.
Remedy: Use commands at the machine to lower the nozzle station and restart operation. If the nozzle
station is at its lowered position when this message appears, check the lower limit sensor.
------------------------------
Code: 1207E?6D
Display: "SCU? (PMC?, ICM) Error Code:********"
"Remover-lifter not lowered"(QP2)
Remover origin position error.(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The remover-lifter is not at its lowered position.(QP2)
The tray remover is not attached to the lifter.(NP2,QP3)
Remedy: Use commands at the machine to lower the remover-lifter and restart operation. If the remover-
lifter is at its lowered position when this message appears, check the lower limit sensor.(QP2)
Return tray remover to the lifter (auto recovery failed).If the remover is correctly attached to the
lifter, check the action of the tray remover detection sensor.(NP2,QP3)
------------------------------
Code: 1207E?6E
Display: "SCU? (PMC?, ICM) Error Code:********"
"Placed parts dislodged"
Used by: QP201
Cause: The parts was partially or completely dislodged from the FOL carrier. The question marks (?)
represent the module number. The asterisks (***) represent the error code.
Remedy: Check that the parts are being correctly placed, and that they are securely in position on the
第 833 页
carrier. Care should be taken as the parts may become dislodged.
------------------------------
Code: 1207E?6F
Display: "SCU? (PMC?, ICM) Error Code:********"
"Pocket unclamping error"
Used by: QP201
Cause: The FOL carrier pocket clamps were not released within the required time.(The question marks
represent the module number, and the asterisks represent the error code.)
Remedy: Check the action of the pocket clamps.
------------------------------
Code: 1207E?70
Display: "SCU? (PMC?, ICM) Error Code:********"
"Packages on carrier"
Used by: QP201
Cause: Packages ware detected on the carrier during conveyance.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Check whether there are packages on the carrier.
------------------------------
Code: 1207E?71
Display: "SCU? (PMC?, ICM) Error Code:********"
"Part supply direction error"
Used by: QP203
Cause: The supply direction of the heat spreader parts on the coin stack feeder may be incorrect.(The
question marks represent the module number, and the asterisks represent the error code.)
Remedy: Check the direction of the spreader parts on the coin stack feeder.
------------------------------
Code: 1207E?72
Display: "SCU? (PMC?, ICM) Error Code:********"
"Feeder interference area"
Used by: QP203
Cause: The head is inside the coin stack feeder interference area.(The question marks represent the
module number, and the asterisks represent the error code.)
Remedy: Move the head outside the coin stack feeder interference area.
------------------------------
Code: 1207F?00
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Controller Error"
Used by: QP242
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
Code: 1207F?01
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. This error may also be caused by breaks in cables, or by
第 834 页
malfunctions of the communication board or the RB controller.
------------------------------
Code: 1207F?02
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error During Axis Movement"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?03
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Protocol Error"
Used by: QP242
Cause: A protocol error (a parity error, framing error, or an overrun error) occurred while receiving data.
The RB unit ALM light is on.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation. It is possible that the cable, communication board, or
RB controller is faulty.
------------------------------
Code: 1207F?04
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Disconnected Axis"
Used by: QP242
Cause: The specified axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?05
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit. The ALM lamp on the RB unit
will light when this error occurs. (If the new RB unit is being used, an amp driver alarm will be indicated.)
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. (If the new RB unit is being used, check the amp driver power
supply.)
------------------------------
Code: 1207F?06
Display: "SCU?(ICM,PMC?) Error Code:********"
"RB Servo Error Controller Processing"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------