setup station and the in-position. Remedy: Check the slide's extended position. Check the I/O signal X070 when the slide is at its extended position. ------------------------------ Code: 12054095 Display: "SETU…
Code: 1205408E
Display: "SETUP_ST. IN Feeder Time Out"
Used by: CP652C
Cause: The cylinder used to clamp the pallet, when clamping is attempted by the in-setup station
cylinder, has not reached the clamp position in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the in-setup station cylinder.
Check the input status of the extended (X072) and retract (X073) position for the in-setup station cylinder.
------------------------------
Code: 1205408F
Display: "SETUP_ST. IN Slide Time Out"
Used by: CP652C
Cause: Operation of the in-setup station slide has not been completed in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the in-setup station slide.
Check the input status of the extended (X070) and retract (X071) position for the in-setup station slide.
------------------------------
Code: 12054090
Display: "SETUP_ST. OUT Feeder Time Out"
Used by: CP652C
Cause: The cylinder used to clamp the pallet, when clamping is attempted by the out-setup station
cylinder, has not reached the clamp position in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the out-setup station cylinder.
Check the input status of the extended (X07A) and retract (X07B) position for the out-setup station
cylinder.
------------------------------
Code: 12054091
Display: "SETUP_ST. OUT Slide Time Out"
Used by: CP652C
Cause: Operation of the out-setup station slide has not been completed in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the out-setup station slide.
Check the input status of the extended (X078) and retract (X079) position for the out-setup station slide.
------------------------------
Code: 12054092
Display: "SETUP_ST. IN Interlock on"
Used by: CP652C
Cause: The pallet pass-through sensor between the in-setup station and in-position is detecting a pallet
as the in-setup station slide attempts to move.
Remedy: Remove the obstruction.
Check the pallet pass-through sensor (X06E).
------------------------------
Code: 12054093
Display: "SETUP_ST. OUT Interlock on"
Used by: CP652C
Cause: The pallet pass-through sensor between the out-setup station and out-position is decting a pallet
as the out-setup station slide attempts to move.
Remedy: Remove the obstruction.
Check the pallet pass-through sensor (X06F).
------------------------------
Code: 12054094
Display: "SETUP_ST. IN Origin Position Error"
Used by: CP652C
Cause: The slide is off-center of the extended position when the pallet attempts to move between the in-
第 563 页
setup station and the in-position.
Remedy: Check the slide's extended position.
Check the I/O signal X070 when the slide is at its extended position.
------------------------------
Code: 12054095
Display: "SETUP_ST. OUT Origin Position Error"
Used by: CP652C
Cause: The slide is off-center of the extended position when the pallet attempts to move between the out-
setup position and the out-position.
Remedy: Check the slide's extended position.
Check the I/O signal X078 when the slide is at its extended position.
------------------------------
Code: 12054096
Display: "Pallet Clamp Err SET_ST. IN(OUT)"
Used by: CP652C
Cause: Before operation is started:
- The setup station's (in/out) pallet clamp is not engaged properly or, the state in which it is disengaged is
abnormal.
- There is a pallet at the setup station (in/out) as well as the pallet's ID information data but the pallet is
not clamped.
During operation:
- The pallet that arrived at the setup station (in/out) can not be clamped properly when the attempt is
made.
Remedy: Check that the pallet is clamped properly at the setup station (in/out).
Check the input status for each of the clamping pin sensors.
Pallet clamp sensor (setup station IN:X074, OUT:X07C), pallet unclamp sensor (setup station IN:X075,
OUT:X07D), pallet sensor (setup station IN:X076, OUT:X07E).
Check that the D-axis pallet ID data matches that of the current pallet position using the command
sequence [SET] -> [POSITION] -> [SET PALLET] -> [DEFINE].
Clamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): on
- Unclamp sensor (IN:X075) (OUT:X07D): off
- Pallet sensor (IN:X076) (OUT:X07E): on
Unclamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): off
- Unclamp sensor (IN:X075) (OUT:X07D): on
- Pallet sensor (IN:X076) (OUT:X07E): on
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054097
Display: "Pallet Unclamp Err SET_ST. IN(OUT)"
Used by: CP652C
Cause: The pallet clamp attempted to disengage when the pallet moved from the setup station (in/out),
but has not disengaged properly.
Remedy: Check the input status for each of the setup stations' clamp pin sensors.
Pallet clamp sensor (setup station IN:X074, OUT:X07C), pallet unclamp sensor (setup station IN:X075,
OUT:X07D), pallet sensor (setup station IN:X076, OUT:X07E).
Clamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): on
- Unclamp sensor (IN:X075) (OUT:X07D): off
第 564 页
- Pallet sensor (IN:X076) (OUT:X07E): on
Unclamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): off
- Unclamp sensor (IN:X075) (OUT:X07D): on
- Pallet sensor (IN:X076) (OUT:X07E): on
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054098
Display: "Filler Conveyor Set Error"
Used by: CP652C
Cause: When the PPS filler operation is performed, the filler conveyor is not set correctly at the time the
pallet moves from the return conveyor to the filler conveyor.
When the PPS filler operation is not performed, the filler conveyor set sensor is detecting the presence of
the filler conveyor.
Remedy: Check the set status of the filler conveyor.
When the filler conveyor has not been set, the input status for each of the sensors are as follows:
Set state:
- Joint conveyor present X095:X
- Joint conveyor set sensor 1 X096: O
- Joint conveyor set sensor 2 X097: O
Unset state:
- Joint conveyor present X095:O
- Joint conveyor set sensor 1 X096: X
- Joint conveyor set sensor 2 X097: X
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054099
Display: 周期异常 洗净剂喷嘴
Used by: GPX,GPX-C
Cause: 洗净剂喷嘴在规定时间内没有动作
Remedy: 1.如果存在妨害洗净剂供应喷嘴上下动作的东西,请除去障害物。
2.如果没有障害物,请通过I/O确认洗净剂供应喷嘴上下的输入,检查洗净剂供应喷嘴上下解除确认的传感器。
(RX00A.00B)(请与敝公司Support联系)
3.如果子编码中显示UpDown Sensor Adjustment,请进行溶剂供应的上升下降端传感器位置的调整。
<img src="$LKEY_ERRIMG_MC$/EI0022.bmp">
------------------------------
Code: 1205409A
Display: 周期异常 轮廓夹紧
Used by: GPX,NXTP,GPX-C
Cause: 轮廓夹紧的导入端或退出端在规定时间内没有ON。
轮廓夹紧的导入、退出的传感器同时ON着。
Remedy: 1.如果有障害物(电路板等),请除去障害物。
2.请通过I/O检查轮廓夹紧导入确认和轮廓夹紧解除确认的传感器(GPX:RX001-004, NXTP:RX00D-020)。(请与
敝公司Support联系)
3.Sensor Adjustment:请进行轮廓夹紧导入退出端传感器的调整。
<img src="$LKEY_ERRIMG_MC$/1205409A.PNG">
------------------------------
Code: 1205409B
Display: 周期异常 框松开
第 565 页