FUJI错误代码查询.pdf - 第719页

"No dummy parts" (QP2) Used by: QP202 Cause: Run out of dummy parts. Remedy: Resupply the dummy parts tray. ------------------------------ Code: 12070?1C Display: "ICM(PMC?,SCU?) Error code:********" …

100%1 / 5282
------------------------------
Code: 12070?17
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Pre-picked Part Exists" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because a pre-picked part exists.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, then use commands to dump parts. If the problem
occurs again, use a reset-start to transmit the control software to the PMCs. If the problem is recurring,
issues such as a faulty PMC control board may be the cause.
------------------------------
Code: 12070?18
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Program" (QP2)
PM?? ERROR Code:******** (QP132)
"No Production Program" (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine did not contain the program named in the pallet ID. This error may also occur
during index operation in a mode other than automatic mode, or as the result of a QP1 firmware
malfunction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: QP1 specifications do not allow the deletion of a program as long as there is a board being
produced in the machine. This error occurs if there is a pallet in the machine when a program is forcibly
deleted by a command from a host computer, when a program is deleted by a reset start, etc. Since
production cannot be continued in such cases, either use the [SKIP] command to eject the board, or
execute flush-out operation.
------------------------------
Code: 12070?19
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Check Sum Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A checksum error has been found.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?1A
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
"No trays" (QP2)
Used by: QP202,QP203
Cause: No part supply trays are available.
Remedy: Supply trays.
------------------------------
Code: 12070?1B
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
第 718 页
"No dummy parts" (QP2)
Used by: QP202
Cause: Run out of dummy parts.
Remedy: Resupply the dummy parts tray.
------------------------------
Code: 12070?1C
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
"Head above tray zero set not possible" (QP2)
Used by: QP202,QP203
Cause: Head is positioned above tray and may interfere with tray during zero setting.
Remedy: Move the head away from the tray using the inching keys.
------------------------------
Code: 12070?1D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Orientation Check Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The recovery limit has been reached due to orientation errors.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Correct the orientation of the parts.
------------------------------
Code: 12070?20
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Insufficient Free Memory" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The remaining free memory is insufficient.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMC. If the problem is recurring, issues such as a
faulty production program or PMC control board may be the cause.
The maximum number of sequences per production program is 5000, and the maximum number of
sequences for a PLM (PM), including mark sequences is 1000.
------------------------------
Code: 12070?21
Display: PM?? ERROR Code:********
"Pallet ID reading error"(QP132)
Used by: QP132
Cause: The pallet ID cannot be read. This is a pallet ID controller error. ?? indicates the module
number. **** indicates the command name in which the error occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Check the pallet position. Check the error code which is displayed by the ID controller LED.
------------------------------
Code: 12070?22
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Final Position NG" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The IN position is inappropriate.
(value replacing "?" is module number; error code appears in place of asterisks)
第 719 页
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?23
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Z Axis Not at Origin" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The Z-axis is not at the origin position.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use inching or another method to return the Z-axis to the origin position, then restart. If the
machine has a sensor at the Z-axis origin position, check the sensor input.
------------------------------
Code: 12070?24
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Fiducial Mark Data" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The program does not contain sufficient fiducial marks to allow component placement.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the fiducial marks and the mark sequences in the program that caused the error, then
retransmit the program.
------------------------------
Code: 12070?25
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Check Sum Data Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command contains erroneous checksum data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?26
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Board Attribute Data" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine does not contain any attribute data for a board. When a board's fiducial marks are
read at the mark reading station, a pallet data table is created that contains information such as mark
deviation amounts and block skip data. Although this data is supposed to be assured until the pallet is
ejected, the table corresponding to the pallet in question could not be found. This error may also occur
during index operation in a mode other than automatic mode, or as the result of a QP1 firmw re
malfunction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 720 页