Display: 1CB07006 Used by: Cause: Mark is distorted. Remedy: Verify that the entire mark fits in the window. ------------------------------ Code: 1CB07007 Display: 1CB07007 Used by: Cause: Mark size exceeds the tolerance…

100%1 / 5282
------------------------------
Code: 1CB06003
Display: 1CB06003
Used by: NP133
Cause: The vision window used to calculate the histogram is larger than the image range.
Remedy: Check whether the entered diameter for the nozzle reflective disk is larger than the image range.
Check that there are no marks on the reflective surface which could be mistaken for the nozzle.
------------------------------
Code: 1CB06004
Display: 1CB06004
Used by: NP133
Cause: The calculated average is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB06005
Display: 1CB06005
Used by: NP133
Cause: The calculated standard deviation is not in the range 0 to 255.
Remedy: Rarely occurring error. Contact Fuji if this error occurs.
------------------------------
Code: 1CB07001
Display: 1CB07001
Used by:
Cause: Data required for processing has not been entered.
Remedy: Specify the mark size, camera resolution, and window size.
------------------------------
Code: 1CB07002
Display: 1CB07002
Used by:
Cause: Mark is too large.
Remedy: Specify the setting so that mark fits in the window.
------------------------------
Code: 1CB07003
Display: 1CB07003
Used by:
Cause: Window area (range) is incorrect.
Remedy: Specify the window range so that the window fits in the screen.
------------------------------
Code: 1CB07004
Display: 1CB07004
Used by:
Cause: No image contrast.
Remedy: Check to see if the image is being acquired properly. Also verify that the nozzle is correct.
------------------------------
Code: 1CB07005
Display: 1CB07005
Used by:
Cause: No mark at the specified position.
Remedy: Check to see if the wrong position was specified.
------------------------------
Code: 1CB07006
第 1207 页
Display: 1CB07006
Used by:
Cause: Mark is distorted.
Remedy: Verify that the entire mark fits in the window.
------------------------------
Code: 1CB07007
Display: 1CB07007
Used by:
Cause: Mark size exceeds the tolerance range.
Remedy: Increase the tolerance value.
------------------------------
Code: 1CC01001
Display: 1CC01001
Used by:
Cause: The check window is outside of the scan area.
Remedy: Check the coordinates of the check window.
------------------------------
Code: 1CC01002
Display: 1CC01002
Used by:
Cause: The specified window size is unsuitable.
Remedy: Check the window area specified at the MCS.
------------------------------
Code: 1CC01003
Display: 1CC01003
Used by: IP3
Cause: A vision processing error occurred during the part polarity check.
Remedy: Check the direction in which the parts are supplied.
------------------------------
Code: 1CC01101
Display: 1CC01101
Used by:
Cause: The value input for the back light diameter is 0.
Remedy: Input the correct back light diameter in part data.
------------------------------
Code: 1CC02001
Display: 1CC02001
Used by:
Cause: The check window is outside of the scan area.
Remedy: Check the coordinates of the check window.
------------------------------
Code: 1CC02002
Display: 1CC02002
Used by:
Cause: The specified window size is unsuitable.
Remedy: Check the window area specified at the MCS.
------------------------------
Code: 1CC02003
Display: 1CC02003
Used by:
Cause: A vision processing error occurred during the part polarity check.
第 1208 页
Remedy: Check the direction in which the parts are supplied.
------------------------------
Code: 1CC02102
Display: 1CC02102
Used by:
Cause: The value input for the back light diameter is 0.
Remedy: Input the correct back light diameter in part data.
------------------------------
Code: 1CC03001
Display: 1CC03001
Used by:
Cause: Direction check area is improper.
Remedy: The specified area is too narrow. Increase the area size.
------------------------------
Code: 1CC03011
Display: 1CC03011
Used by:
Cause: The supply orientation of the part is wrong.
Remedy: A bump exists in the specified area (No bump check). Check the supply orientation of the part.
When checking the supply orientation also make sure that there are no errors in the area position and
area range settings.
------------------------------
Code: 1CC03021
Display: 1CC03021
Used by:
Cause: The supply orientation of the part is wrong.
Remedy: A bump does not exist in the specified area (Bump check). Check the supply orientation of the
part. When checking the supply orientation also make sure that there are no errors in the area position
and area range settings.
------------------------------
Code: 1CC03022
Display: 1CC03022
Used by:
Cause: The supply orientation of the part is wrong.
Remedy: Either a bump exists in the specified area or the verified bump that was found did not fit with a
bump that was too small. Check the supply orientation of the part. When checking the supplyorientation
also make sure that there are no errors in the area position and area range settings.
------------------------------
Code: 1CC04001
Display: 1CC04001
Used by:
Cause: The mark check position (area) is outside the body.
Remedy: Enter the correct mark check position (area) coordinates.
------------------------------
Code: 1CC04002
Display: 1CC04002
Used by:
Cause: Mark check area is improper.
Remedy: Enter the correct mark check area coordinates. This error occurs when the X1 and X2, or Y1
and Y2 values are the same.
------------------------------