FUJI错误代码查询.pdf - 第194页
------------------------------ Code: 110742C0 Display: Used by: Cause: The sub-nozzle dropped the part. Remedy: Pick the part again. ------------------------------ Code: 110742D0 Display: Used by: IP2 Cause: Tray set err…
Used by: IP2
Cause: There are no parts in the specified tray.
Remedy: Resupply the tray with parts.
------------------------------
Code: 11074250
Display:
Used by:
Cause: There is no tray.
Remedy: Supply a new tray.
------------------------------
Code: 11074260
Display:
Used by:
Cause: The tray was not ejected.
Remedy: Eject the tray.
------------------------------
Code: 11074270
Display:
Used by: IP2
Cause: The SY axis is not in the safety position.
Remedy: Move the SY axis into the safety position.
------------------------------
Code: 11074280
Display:
Used by: IP2
Cause: Machine can not go into ON_LINE while inching.
Remedy: Wait until after inching is finished.
------------------------------
Code: 11074290
Display:
Used by: IP2
Cause: The carrier and nozzle are full.
Remedy: Remove parts from the carrier and nozzle.
------------------------------
Code: 110742A0
Display:
Used by: IP2
Cause: Parts request command error (not P, I or S).
Remedy: None.
------------------------------
Code: 110742B0
Display:
Used by: IP2
Cause: The specified X position is out of range.
Remedy: None.
------------------------------
Code: 110742B1
Display:
Used by: IP2
Cause: The specified Y position is out of range.
Remedy: None.
第 193 页
------------------------------
Code: 110742C0
Display:
Used by:
Cause: The sub-nozzle dropped the part.
Remedy: Pick the part again.
------------------------------
Code: 110742D0
Display:
Used by: IP2
Cause: Tray set error. The tray is not set correctly.
Remedy: Set the tray correctly.
------------------------------
Code: 110742E0
Display:
Used by: IP2
Cause: The tray is not in its original position.
Remedy: Return the tray to its original position.
------------------------------
Code: 110742F0
Display:
Used by: IP2
Cause: The tray chute is not set.
Remedy: Set the tray chute.
------------------------------
Code: 11074300
Display:
Used by: IP2
Cause: Proper data's X axis travel time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074301
Display:
Used by: IP2
Cause: Proper data's Y axis travel time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074302
Display:
Used by: IP2
Cause: Proper data's T axis travel time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074303
Display:
Used by: IP2
Cause: Proper data's X axis deceleration point is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074304
Display:
第 194 页
Used by: IP2
Cause: Proper data's Y axis deceleration point is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074305
Display:
Used by: IP2
Cause: Proper data's T axis deceleration point is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074306
Display:
Used by: IP2
Cause: Proper data's X axis deceleration time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074307
Display:
Used by: IP2
Cause: Proper data's Y axis deceleration time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074308
Display:
Used by: IP2
Cause: Proper data's T axis deceleration time is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 11074309
Display:
Used by: IP2
Cause: Proper data's T axis reference location is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430A
Display:
Used by: IP2
Cause: Proper data's X axis top speed is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430B
Display:
Used by: IP2
Cause: Proper data's Y axis top speed is out of range.
Remedy: Check the Proper data.
------------------------------
Code: 1107430C
Display:
Used by: IP2
Cause: Proper data's Z axis top speed is out of range.
Remedy: Check the Proper data.