(hexadecimal code): Check the length of the part. ------------------------------ Code: 1D010012 Display: 1D010012 Used by: Cause: The X length is too long (or too short). Remedy: Check the part length. Check that Part da…
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000B
Display: 1D01000B
Used by:
Cause: The X length is too long.
Remedy: Check the length of the part.
------------------------------
Code: 1D01000C
Display: 1D01000C
Used by:
Cause: The X length is inappropriate. (Too long or too short)
Remedy: Check the length of the part.
------------------------------
Code: 1D01000D
Display: 1D01000D
Used by:
Cause: The image was not read correctly. Protrusions and indentations on the upper and lower edges
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000E
Display: 1D01000E
Used by:
Cause: The image was not read correctly. Protrusions and indentations on the upper and lower edges
are too large. A foreign object is attached to the part.
Remedy: Check the camera, the vision processing board, associated cables and the focus. Place this part
using Computer Vision #6. Remove any foreign objects.
------------------------------
Code: 1D01000F
Display: 1D01000F
Used by:
Cause: The Y length is too short.
Remedy: Check the length of the part.
------------------------------
Code: 1D010010
Display: 1D010010
Used by:
Cause: (4 digit decimal code) : The part is tilted at an angle exceeding 45 deg..
(hexadecimal code): The Y direction dimension is too short.
Remedy: (4 digit decimal code): Check that the nozzle is clean, and that the part is clean. Check that the
correct part is being picked. (hexadecimal code): Check the length of the part.
------------------------------
Code: 1D010011
Display: 1D010011
Used by:
Cause: (4 digit decimal code): The X length is too short. (hexadecimal code): The Y length is too short.
Remedy: (4 digit decimal code): Check the part length. Check that Part data is accurate to within +-20%.
第 1237 页
(hexadecimal code): Check the length of the part.
------------------------------
Code: 1D010012
Display: 1D010012
Used by:
Cause: The X length is too long (or too short).
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D010013
Display:
Used by:
Cause: The part is tilted at an angle exceeding 45 deg..
Remedy: Check that the nozzle is clean, and that the part is clean. Check that the correct part is being
picked.
------------------------------
Code: 1D010014
Display:
Used by:
Cause: There are more than 3 parts where the area to the left and right is not evenly shaped.
Remedy: Place these parts using Computer Vision #6.
------------------------------
Code: 1D010015
Display:
Used by:
Cause: The Y length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D010016
Display:
Used by:
Cause: There are more than 3 parts where the area to the left and right is not unevenly shaped.
Remedy: Place these parts using Computer Vision #6.
------------------------------
Code: 1D010017
Display:
Used by:
Cause: The Y length is too short.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D010018
Display:
Used by:
Cause: The Y length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D010019
Display:
Used by:
Cause: The X length is too short.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
第 1238 页
Code: 1D01001A
Display:
Used by:
Cause: The X length is too long.
Remedy: Check the part length. Check that Part data is accurate to within +-20%.
------------------------------
Code: 1D01001B
Display:
Used by:
Cause: The X length is too long.
Remedy: Check the part length.
------------------------------
Code: 1D01001C
Display:
Used by:
Cause: The Y length is too short.
Remedy: Check the part length.
------------------------------
Code: 1D01001D
Display:
Used by:
Cause: Vision processing is not going well (the nozzle is dirty, the parts are not clean), the part is not
evenly shaped, or the value in Part data is smaller than the real part.
Remedy: If the nozzle and parts are clean, check that the parts are not incorrect.
------------------------------
Code: 1D01001E
Display:
Used by:
Cause: Vision processing is not going well (the nozzle is dirty, the parts are not clean), the part is not
evenly shaped, or the value in Part data is smaller than the real part.
Remedy: If the nozzle and parts are clean, check that the parts are not incorrect.
------------------------------
Code: 1D01001F
Display:
Used by:
Cause: Vision processing is not going well (the nozzle is dirty, the parts are not clean), the part is not
evenly shaped, or the value in Part data is smaller than the real part.
Remedy: If the nozzle and parts are clean, check that the parts are not incorrect.
------------------------------
Code: 1D010020
Display:
Used by:
Cause: Vision processing is not going well (the nozzle is dirty, the parts are not clean), the part is not
evenly shaped, or the value in Part data is smaller than the real part.
Remedy: If the nozzle and parts are clean, check that the parts are not incorrect.
------------------------------
Code: 1D010021
Display:
Used by:
Cause: Vision processing cannot take a correct part image. The upper and lower parts of the part are too
uneven. There is foreign matter stuck to the part.