Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data. ------------------------------ Code: 51??2100 Display: No "UNIT", "STATUS&quo…
"BLOCK", "PLTDT+" were insufficient.
Remedy: Check the settings for the "GUISTN" data lines in "UNIT", "PALLET" - "BLOCK", "PLTDT+" in the
specified pallet data file. "GUISTN" must record all of the numbers from 1 up to the number required by
the applicable machine type.
------------------------------
Code: 51??2000
Display: No "UNIT", "PALLET" or "UNIT", "PALLET" is not at the correct position.
Used by:
Cause: "UNIT", "PROPER" was not found in the specified Proper data. Alternatively, "UNIT", "PROPER"
does not follow the correct unit.
Remedy: Check the setting for "UNIT", "PROPER" in the Proper data.
------------------------------
Code: 51??2001
Display: No ""UNIT", "PROPER" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER-" was not found in "UNIT", "PROPER" in the specified Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "HEADER-" in the Proper data.
------------------------------
Code: 51??2002
Display: No ""UNIT", "PROPER" - "BLOCK", "PROPDT-".
Used by:
Cause: "BLOCK", "PROPDT-" was not found in "UNIT", "PROPER" in the specified Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data.
------------------------------
Code: 51??2005
Display: No ""UNIT", "PROPER" - "BLOCK", "IMAGE-".
Used by:
Cause: "BLOCK", "IMAGE" was not found in "UNIT", "PROPER" in the specified transmission image type
Proper data.
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "IMAGE-" in the Proper data. Furthermore,
check "FILESTRUCT" in "UNIT", "STRUCT".
------------------------------
Code: 51??2006
Display: No vQN line in "UNIT", "PROPER" - "BLOCK", "IMAGE-".
Used by:
Cause: The vQN line was not found in "UNIT", "PROPER" - "BLOCK", "IMAGE" in the specified
transmission image type Proper data.
Remedy: Check the content of "UNIT", "PROPER" - "BLOCK", "IMAGE-" in the production program.
------------------------------
Code: 51??2011
Display: Format error in "UNIT", "PROPER" - "BLOCK", "HEADER-".
Used by:
Cause: "UNIT", "PROPER" in the specified Proper data was read and a format error was detected in
"BLOCK", "HEADER-".
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "HEADER-" in the Proper data.
------------------------------
Code: 51??2012
Display: Format error in "UNIT", "PROPER" - "BLOCK", "PROPDT-".
Used by:
Cause: "UNIT", "PROPER" in the specified Proper data was read and a format error was detected in
"BLOCK", "PROPDT-".
第 2246 页
Remedy: Check the setting for "UNIT", "PROPER" - "BLOCK", "PROPDT-" in the Proper data.
------------------------------
Code: 51??2100
Display: No "UNIT", "STATUS" or "UNIT", "STATUS" is not at the correct position.
Used by:
Cause: "UNIT", "STATUS" was not found in the specified status data or "UNIT", "STATUS" does not follow
the correct unit.
Remedy: Check the "UNIT", "STATUS" setting in status data. Alternatively, check the setting of the "UNIT"
line prior to "UNIT", "STATUS".
------------------------------
Code: 51??2101
Display: No "UNIT", "STATUS" - "BLOCK", "HEADER-".
Used by:
Cause: "BLOCK", "HEADER-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS" - "BLOCK", "HEADER-".
------------------------------
Code: 51??2102
Display: No "UNIT", "STATUS" - "BLOCK", "STATDT-".
Used by:
Cause: "BLOCK", "STATDT-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS" - "BLOCK", "STATDT-".
------------------------------
Code: 51??2105
Display: No "UNIT", "STATUS" - "BLOCK", "IMAGE-".
Used by:
Cause: "BLOCK", "IMAGE-" was not found in the specified status data's "UNIT", "STATUS".
Remedy: Check the setting for status data's "UNIT", "STATUS"-"BLOCK", "IMAGE-". Furthermore, check
"FILESTRUCT" in "UNIT", "STRUCT".
------------------------------
Code: 51??2106
Display: No vQN line in "UNIT", "STATUS" - "BLOCK", "IMAGE-".
Used by:
Cause: The vQN line in "UNIT", "STATUS" - "BLOCK", "IMAGE-" in the specified transmission image type
status data was not found.
Remedy: Check the content of "UNIT", "STATUS" - "BLOCK", "IMAGE-" in the production program.
------------------------------
Code: 51??2111
Display: "UNIT", "STATUS" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "STATUS" in the specified status data was read and a format error was detected in
"BLOCK", "HEADER-".
Remedy: Check the setting for "UNIT", "STATUS" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 51??2112
Display: "UNIT", "STATUS" - "BLOCK", "STATDT-" format error.
Used by:
Cause: "UNIT", "STATUS" in the specified status data was read and a format error was detected in
"BLOCK", "STATDT-".
Remedy: Check the setting for "UNIT", "STATUS" - "BLOCK", "STATDT-" in status data.
------------------------------
Code: 51??4001
第 2247 页
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------
Code: 51??4002
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------
Code: 51??4003
Display: The cell status is underfined.
Used by:
Cause: A board type report was confirmed for a machine with an underfined cell status.
Remedy: Request the cell status.
------------------------------
Code: 51??4004
Display: Named pipe could not be created.
Used by:
Cause: The named pipe used to read the CCPSS process could not be created or opened.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4005
Display: Remote command named pipe could not be opened.
Used by:
Cause: The named pipe used to read the remote command could not be opened.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4006
Display: No reply from command server to the transmit OK request.
Used by:
Cause: An attempt was made to receive a reply from the command server to the transmit OK request but
a read error occurred in the named pipe. This error occurs if there is a named pipe read error or an
incorrect format for the transmit OK request, and may be caused by the C/C not operating properly.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4007
Display: Remote command did not start.
Used by:
Cause: An attempt was made to receive a startup report from the remote command but a read error
occurred in the named pipe. This error occurs if there is a named pipe read error and may be caused by
the C/C not operating properly.
Remedy: Switch the power off and then on.
------------------------------
Code: 51??4008
Display: Presently not used.
Used by:
Cause:
Remedy:
------------------------------