FUJI错误代码查询.pdf - 第2149页
Code: 2304004A Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the loop? . Used by: Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. …
Used by:
Cause: When the nozzle array is set to automatic configuration, the number of necessary nozzles exceeds
the maximum number of nozzles on the revolver, 12.
Remedy: There is an error in the program file. Revise the nozzle specification file, or revise the nozzle
name, minimum nozzle diameter (PARTS/ENVDT/XP141ENVDT-/PENMI) and maximum nozzle diameter
(PARTS/ENVDT/XP141ENVDT-/PENMA) fields in the part data.
------------------------------
Code: 23040044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP141ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP141ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23040045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Nozzle Name (PARTS/ENVDT/XP141ENVDT-
/PENNZN) in the part data.
------------------------------
Code: 23040047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23040048
Display: Two or more first slots (reference slot) have been specified for the same alternate feeder loop. The
Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 23040049
Display: Two or more first slots (reference slots) have been specified for the same alternate feeder loop.
The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
第 2148 页
Code: 2304004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop? .
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2304004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2304004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230400A3
Display: Optimization cannot be performed if there are less than two active fiducial marks.
Used by:
Cause: Optimization cannot be performed for programs containing less than two active fiducial marks,
including skipped marks.
Remedy: Add two or more active fiducial mark sequences to the program.
------------------------------
Code: 230400A4
Display: Optimization cannot be performed because no valid placement sequences exist.
Used by:
Cause: Optimization cannot be performed because all placement sequences are skipped.
Remedy: The program must contain at least one placement sequence that is not to be skipped.
------------------------------
Code: 23040102
Display: Only 8mm and 12mm feeders can be handled by the XP-141E.
Used by:
Cause: The tape width indicated in Tape Width (PARTS/PACKLS-/TAPEWIDTH) or Packaging Name
(PARTS/HEADER/CMPNAME) is neither 8mm nor 12mm. This feeder cannot be mounted on the XP-141E.
Remedy: There is an error with the tape width specified in the part data of the program file. Correct the
error.
------------------------------
Code: 23040105
Display: Unused Nozzle(s) exist in the Revolver. Continue?
Used by:
Cause: Unused nozzle(s) exist in the revolver, or unusable nozzles are set in the revolver.
Remedy: Optimize with 乬Configure feeders automatically乭, or revise the nozzle array in the program file
or with manual input.
------------------------------
第 2149 页
Code: 23040106
Display: The Alt. Feeder number must be set to a different slot. Set the final slot in the loop to point back
to the first slot in the loop.
Used by:
Cause: An Alt. Feeder number has been set for the same slot.
Remedy: In the program file's feeder setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 23050003
Display: The tape width is outside the specifications or is zero.
Used by:
Cause: The Packaging Name (PARTS/HEADER/CMPNAME) or the Tape Width (PARTS/PACKLS-
/TAPEWIDTH) is outside the specifications or is zero. For Packaging Name, one of the following types
must be specified: E08xx, E12xx, E16xx, E24xx, E32xx, J32xx, E44xx, E56xx, E72xx, E88xx. For Tape
Width, one of the following must be specified: 8, 12, 16, 24, 32, 44, 56, 72, 88.
Remedy: The tape width setting in the part data is incorrect. Check the file contents.
------------------------------
Code: 23050004
Display: Part Transport Speed is zero.
Used by:
Cause: Part Transport Speed (PARTS/ENVDT/XP241ENVDT-/PENSPD1) is zero.
Remedy: The Part transport speed setting in the part data is incorrect. Check and correct the setting.
------------------------------
Code: 23050005
Display: A feeder or tray does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder or tray does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23050006
Display: Part data referred to by the sequence slot does not exist.
Used by:
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence
setting, does not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23050008
Display: No feeder or tray exists in the slot referenced by this skipped sequence (for skipped sequences
included in optimization).
Used by:
Cause: A feeder or tray does not exist in a sequence slot that contains board/feeder/sequence skip
settings.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2305000A
Display: No part data exists for the slot referenced by this skipped sequence (for skipped sequences
included in optimization).
Used by:
Cause: The part data referred to by a sequence slot containing board/feeder/sequence skip settings does
not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
第 2150 页