Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F7E
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F7F
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F80
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal warning.
Remedy: This is not an error message. It is a warning. It does not constitute a problem.
------------------------------
Code: 12031F88
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F89
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F8A
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12031F8B
Display:
Used by: QP242,QP201,QP202,QP203
Cause: Unit number F (VM 1440). Communication internal alarm.
Remedy: Either the CPU board or the VM 1440 board is defective. Contact Fuji.
------------------------------
Code: 12033001
Display: IMAGE SENSOR IS BUSY
IMAGE SENSOR BUSY ERROR
Used by: IP1,IP2
Cause: The image sensor board was previously in operation, so the image could not be taken.
Remedy: Check the image sensor board on the VME rack. Take note of the data displayed.
------------------------------
第 429 页
Code: 12033002
Display: IMAGE SENSOR IS NO GOOD
IMAGE SENSOR COMP ERROR
Used by: IP1,IP2
Cause: The signal to take an image is not coming out of the image sensor board.
Remedy: Check the connectors on the VME rack's image sensor board. This error message sometimes
occurs when the placing point is lower than coordinate point X0 on the X axis. Check the sequence
coordinates. Take note of the data displayed.
------------------------------
Code: 12034101
Display: PLC Link Alarm (cp6)
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The remote I/O board is not ready.
Remedy: Reboot the machine. If the problem persists contact Fuji.
------------------------------
Code: 12034102
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The remote I/O board circuit is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034104
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The OP link is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034108
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Remote I/O alarm.
Remedy: None.
------------------------------
Code: 12034110
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: An interrupt was not received from the remote I/O board.
Remedy: Check the mother board interrupt jumper.
------------------------------
Code: 12034120
Display:
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: Failed in remote I/O board (1st board) initialization.
Remedy: Reboot the machine.
------------------------------
Code: 12034201
Display:
Used by:
Cause: The remote I/O board is not ready.
Remedy: Change the board.
------------------------------
第 430 页
Code: 12034202
Display:
Used by:
Cause: The remote I/O board circuit is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034204
Display:
Used by:
Cause: The OP link is not ready.
Remedy: Check the cable or the programmable controller.
------------------------------
Code: 12034208
Display:
Used by:
Cause: Remote I/O alarm.
Remedy: None.
------------------------------
Code: 12034210
Display:
Used by:
Cause: An interrupt was not received from the remote I/O board.
Remedy: Check the mother board interrupt jumper.
------------------------------
Code: 12034220
Display:
Used by: None.
Cause: Failed in remote I/O board (2nd board) initialization.
Remedy: Reboot the machine.
------------------------------
Code: 12035101
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 1 system error.
Remedy: Turn off the machine power.
------------------------------
Code: 12035102
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,QP132
Cause: Axis number 1 incorrect command.
Remedy: Turn off the machine power.
------------------------------
Code: 12035103
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
Cause: Axis number 1 placement time too long.
Remedy: Turn off the machine power.
------------------------------
Code: 12035104
Display:
Used by: CP5,CP6,CP6M,CP65,GSP5,GP551,GP6,IP3,NP132,NP133,QP132
第 431 页