FUJI错误代码查询.pdf - 第821页
Code: 1207E?25 Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "Tray Rejection Error" (QP2,QP2,NP3) Used by: QP242,QP201,QP202,QP203,QP2,NP3 Cause: Tray ejection error (tray passage confirmation e…
Code: 1207E?1F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Void Found in Flux" (QP2)
Used by: QP242
Cause: The machine stopped because a void was detected in manual void detection mode.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then execute the [AIR OUT] command.
------------------------------
Code: 1207E?20
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Tank Empty" (QP2)
Used by: QP242
Cause: The flux tank has become empty. (The flux surface sensor has turned on.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then fill the flux tank.
------------------------------
Code: 1207E?21
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Head Jointed Index Unit" (QP2)
Used by: QP242
Cause: The nozzle head cannot be lowered because it is joined to an index unit.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?22
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Automatic tape cutter error" (QP2)
Used by: QP242
Cause: The automatic tape cutter operation timed out.(QP2,QP3)
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
Remedy: Use the I/O commands to check the action of the cutter and the retract confirmation
sensor.(QP2)
Check the status (cable connections, air supply) of the PFU/MFU side displayed in the parameter. If the
problem is hardware related, restart the machine.(QP3)
------------------------------
Code: 1207E?23
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Tray;Last Tray Rejected" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no tray. (The last tray of a tray stacker has been ejected.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then supply tray components.
------------------------------
Code: 1207E?24
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Rejection Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Tray ejection timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the STU and the tray ejection unit for problems.
------------------------------
第 820 页
Code: 1207E?25
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Rejection Error" (QP2,QP2,NP3)
Used by: QP242,QP201,QP202,QP203,QP2,NP3
Cause: Tray ejection error (tray passage confirmation error).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether the ejected tray has gotten caught on something. Make sure the tray ejection
check sensor is functioning normally.
------------------------------
Code: 1207E?26
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Setting Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Board setting error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Set the hole in the board on the reference pin. Make sure that the board setting check sensor is
functioning normally.
------------------------------
Code: 1207E?27
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Clamp/Unclamp Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Board transport error (board clamp/unclamp timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the board elevator. Make sure the board elevator
upper and lower limit sensors are functioning normally.
------------------------------
Code: 1207E?28
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Stpper Up/dwn Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Board transport error (board stopper up/down timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the board stopper. Make sure the board stopper
upper and lower limit sensors are functioning normally.
------------------------------
Code: 1207E?29
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Cyl Fwd/Rtrct Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Nozzle index cylinder forward/retract timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?2A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Chngr Up/Dwn Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Nozzle select station up/down timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the nozzle select station. Make sure the nozzle
第 821 页
select station upper and lower limit sensors are functioning normally.
------------------------------
Code: 1207E?2B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Not in Safe Vertcl Pos." (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The TZ-axis cannot be moved because the TY-axis is not in a position that allows vertical
movement.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to return the TY-axis to a position (i.e., the forward or retract
end) that will allow the TZ-axis to be moved.
------------------------------
Code: 1207E?2C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Not at Forward End" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The TZ-axis cannot be moved because the TY-axis is not at the forward end.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to move the TY axis to the forward end.
------------------------------
Code: 1207E?2D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TZ Incorrect Stop Pos." (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The TY-axis cannot be moved because the TZ-axis is not stopped at the correct position.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to return the TZ-axis to a position that will allow the TY-axis to
be moved.
------------------------------
Code: 1207E?2E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Mag.slot Occupied w/ Tray" (QP2)
Used by: QP242
Cause: A tray cannot be stored in the magazine tray slot because the slot is already occupied by a tray.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the tray from the magazine, and store it at another device position in the magazine.
------------------------------
Code: 1207E?2F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Port Not Set / MTU6" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The MTU6 cannot be started because the RS port has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?30
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Cable Not Conected/MTU6" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The MTU6 cannot be started because the RS cable is not connected.
(value replacing "?" is module number; error code appears in place of asterisks)
第 822 页