FUJI错误代码查询.pdf - 第616页

Display: Used by: GSP5,GP551,GP6 Cause: When the Y- or Z-axis is moving, it interferes with the board holder. Alternately, the board holder interlock sensor is not working correctly. Remedy: Retract the board holder so t…

100%1 / 5282
Code: 12063015
Display: "Screen Error Print Pos"
Used by: GP551,GP6
Cause: Stencil transport was not possible because the stencil at the print position is not set correctly.
(GSP5) The stencil at the print position is not correctly set. (GP6)
Remedy: Move the stencil that was in the process of being transported, to the proper position. (GSP5)
Set the stencil that is at the print position, in the appropriate position to allow the stencilto be clamped.
This error will occur if the stencil cannot be properly clamped at this time. (GP6)
------------------------------
Code: 12063016
Display:
Used by:
Cause: The screen is not set properly in the backside cleaning position so it cannot be transported.
Remedy: Move the screen to where it can be properly transported.
------------------------------
Code: 12063017
Display: "No Stencil At Print Pos"
Used by: GP6
Cause: Automatic operation could not be started because there was no stencil at the print position. Or a
stencil could not be stored in the stocker.
Remedy: Set a stencil.
------------------------------
Code: 12063018
Display:
Used by:
Cause: The mask receiving unit is ascended.
Remedy: Lower the mask receiving unit.
------------------------------
Code: 12063019
Display:
Used by: GSP5
Cause: Even though the camera station is out, the S-axis wants to move out.
Remedy: Retract the camera station.
------------------------------
Code: 1206301A
Display:
Used by: GSP5
Cause: When the camera station is moving, it interferes with the Y-axis. Alternately, the Y-axis interlock
sensor is not working correctly.
Remedy: Retract the Y-axis so that it does not interfere with the camera station. Also, check the interlock
sensor.
------------------------------
Code: 1206301B
Display:
Used by: GSP5
Cause: When the camera station is moving, it interferes with the S-axis. Alternately, the S-axis interlock
sensor is not working correctly.
Remedy: Retract the S-axis so that it does not interfere with the camera station. Also, check the interlock
sensor.
------------------------------
Code: 1206301C
第 615 页
Display:
Used by: GSP5,GP551,GP6
Cause: When the Y- or Z-axis is moving, it interferes with the board holder. Alternately, the board holder
interlock sensor is not working correctly.
Remedy: Retract the board holder so that it does not interfere with the camera station. Also, check the
interlock sensor.
------------------------------
Code: 1206301D
Display:
Used by: GSP5
Cause: The board and the mask expansion rate exceeds the production program's elongation_limit item.
Remedy: Increase the value of the elongation_limit in the production program or change the mask and
board. Alternately, set elongation_limit to 0 and this item will be disabled.
------------------------------
Code: 1206301E
Display:
Used by: GSP5,GP2,GP3
Cause: The screen position compensation was carried out, but the pulse motor moved more than the
value allowed in the Proper data item Max Limit Position ***.
Remedy: Check the mark coordinates in the program. Adjust the screen frame spacers. Check that the
Proper data item Max Limit Position is not set to 0.
------------------------------
Code: 1206301F
Display:
Used by:
Cause: Process timeout occurred during communication.
Remedy: Contact Fuji if this happens frequently.
------------------------------
Code: 12063020
Display:
Used by:
Cause: The stocker data set signal was output, but no reply was received.
Remedy: Check the wiring. Check that the stocker sequencer is operating correctly.
------------------------------
Code: 12063021
Display:
Used by:
Cause: A command was sent to the stocker communication unit but a response was not received within
the specified time limit.
Remedy: Check the wiring. If this error occurs frequently, check the machine version and the stocker
ROM version, and contact Fuji.
------------------------------
Code: 12063022
Display:
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: Communication could not be carried out with the printing measurement machine.
Remedy: Check the wiring between the terminal and the printing measurement machine.
------------------------------
Code: 12063023
Display:
Used by: GSP5
第 616 页
Cause: System error.
Remedy: Cut the power and reboot the machine. If the problem recurs, contact Fuji.
------------------------------
Code: 12063024
Display:
Used by:
Cause: Even though the head was not over the screen, an attempt was made to execute the solder
discharge command.
Remedy: Inch the head over the metal portion of the screen and execute the solder discharge command.
------------------------------
Code: 12063025
Display: Interlock Z
Used by: GSP5
Cause: The camera station may collide with the main table.
Remedy: Inch the Z-axis close to its zero set position (the position at which the Z-axis origin sensor,
Z_AXIS_ZERO, turns on).
------------------------------
Code: 12063026
Display: XL XR Interlock
Used by:
Cause: The L camera and R camera proximity sensor was activated
Remedy: Separate the L and R cameras either manually or by inching.
------------------------------
Code: 12063027
Display: Obstruction In Screen Path
Used by:
Cause: Stencil transport was not possible because of an obstruction in the stencil transport path.
Remedy: Remove the obstruction.
------------------------------
Code: 12063028
Display: 请拆下网板
[Please Screen Release]
Used by: GP551,GP6,GPX,NXTP
Cause: 现在,网板正处于夹紧中。在更换支架时有网板的情况下发生。 存在网板框 (GPX)
Remedy: 请松开网板(指令页 558(2)「松开」),然后拆下。 请将网板框取出。(GPX)
<img src="$LKEY_ERRIMG_MC$/12063028.PNG">
------------------------------
Code: 12063029
Display: "Please Cleaner escape"
Used by: GP551,GP6
Cause: This error occurs if the holder is changed while the cleaner is not at the origin position.
Remedy: Move the cleaner to the origin position (the position at which X05C:CLNR ZERO POS" shows a
value of 0). If necessary, make sure that the lower cleaner origin position check sensor (X05C:CLNRZERO
POS) is functioning normally.
------------------------------
Code: 1206302A
Display: "Cleaner Did Not Connect"
Used by: GP551,GP6
Cause: This error may occur if an attempt is made to close the cleaner head while the connection status
between the cleaner and the cleaner drive axis is inappropriate: either the cleaner notch that connects the
cleaner to the drive axis was not inserted, or the cleaner is not proximate to the drive axis. This error may