FUJI错误代码查询.pdf - 第852页

Code: 1207F?7B Display: "SCU?(PMC?,ICM) Error Code:********" "FX-Axis Servo Controller Axis Stop" Used by: QP242 Cause: Command execution was not possible because the RB controller was busy processing…

100%1 / 5282
Used by: QP242
Cause: The machine attempted to take an encoder count before the current count had been confirmed.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?76
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Encorder Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?77
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Encorder Counter Recieving Error"
Used by: QP242
Cause: An error occurred at the FX-axis servo controller when receiving data.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?78
Display: "SCU?(PMC?,ICM) Error Code:********"
"Disconnected FX-Axis"
Used by: QP242
Cause: FX-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?79
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Controller Timeout"
Used by: QP242
Cause: The FX-axis timed out.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?7A
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Controller Busy"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2)
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
第 851 页
Code: 1207F?7B
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Controller Axis Stop"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
Code: 1207F?7C
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Limit Error"
Used by: QP242
Cause: The maximum or minimum position for the axis controlled by the Robustshin servo motor has
been exceeded. Alternatively, something may be obstructing the overtravel sensor for that axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Return the axis in question to a position within the maximum and minimum range using the
inching keys and check those values.
------------------------------
Code: 1207F?7D
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Limit Check Error"
Used by: QP242
Cause: The Robustshin servo motor attempted to move its axis to a position out side the range of its
maximum and minimum values.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: The Robustshin servo motor cannot move an axis outside the maximum or minimum range.
Check these maximum and minimum values. Alternatively, check the position to which the Robustshin
servo motor is attempting to move the axis.
------------------------------
Code: 1207F?7E
Display: "SCU?(PMC?,ICM) Error Code:********"
"No FX-Axis System Call"
Used by: QP242
Cause: System call cannot be carried out because internal data is corrupted.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?7F
Display: "SCU?(PMC?,ICM) Error Code:********"
"No FX-Axis Servo Control Block"
Used by: QP242
Cause: Internal data is corrupted.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?80
第 852 页
Display: "SCU?(ICM,PMC?) Error Code:********"
"PX-Axis Servo Alarm Controller Error"
Used by: QP242
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
Code: 1207F?81
Display: "SCU?(ICM,PMC?) Error Code:********"
"PX-Axis Servo Alarm Communication Timeout"
Used by: QP242
Cause: A timeout occurred during communication with the RB servo unit.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. This error may also be caused by breaks in cables, or by
malfunctions of the communication board or the RB controller.
------------------------------
Code: 1207F?82
Display: "SCU?(ICM,PMC?) Error Code:********"
"PX-Axis Servo Alarm During Axis Movement"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?83
Display: "SCU?(ICM,PMC?) Error Code:********"
"PX-Axis Servo Alarm Protocol Error"
Used by: QP242
Cause: A protocol error (a parity error, framing error, or an overrun error) occurred while receiving data.
The RB unit ALM light is on.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation. It is possible that the cable, communication board, or
RB controller is faulty.
------------------------------
Code: 1207F?84
Display: "SCU?(ICM,PMC?) Error Code:********"
"PX-Axis Servo Alarm Disconnected Axis"
Used by: QP242
Cause: PX-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?85
Display: "SCU?(ICM,PMC?) Error Code:********"
"PX-Axis Servo Alarm Communication Timeout"
Used by: QP242
第 853 页