Code: 11010101 Display: Program 0011 Program NG 0011 Used by: GL2,GL541,IP1,QP242,QP201,QP202,QP203 Cause: The referent mark number sequence set in the mount sequences (application sequence, print sequence) cannot be fou…
------------------------------
Code: 11010001
Display: Program NG 0001
Used by: QP242,QP201,QP202,QP203
Cause: The production program fiducial number ("MN" in sequence data:N_data) is at zero.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010003
Display: Program 0003
Program NG 0003
Used by: GL2,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The mark read sequences are placed after the mount sequences
(application sequences, print sequences).
Remedy: Place the mark read sequences before the mount sequences.
------------------------------
Code: 11010004
Display: Program 0020
Program 0004
Program Mark Read
Used by: GL2,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP2,QP242,QP201,QP202,QP203
Cause: On the GSP, either there is a sequence for a mark which cannot be read and the screen
compensation cannot be calculated or there is a skip sequence in the production program.
Remedy: On the GL, GSP2 and IP2, the set mark read sequence is skipping.
------------------------------
Code: 11010005
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The production program fiducial number ("MN" in sequence data:N_data) is repeating itself.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010006
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The main mark and sub mark in the production program ("MM" and "SM" in sequence data:
N_data) are the same number (but not zero).
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010007
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The fiducial number ("MN" in sequence data: N_data) registered with the production program
main mark ("MM" in sequence data: N_data) does not exist.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010008
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The fiducial number ("MN" in sequence data: N_Data) registered with the production program sub
mark ("SM" in sequence data: N_Data) does not exist.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
第 1 页
Code: 11010101
Display: Program 0011
Program NG 0011
Used by: GL2,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The referent mark number sequence set in the mount sequences (application sequence, print
sequence) cannot be found.
Remedy: Check MCS. If only one referent mark is to be used, enter the same number for main mark and
sub mark. If the sub mark is set to zero this error will occur. Also check the displayed sequence mark
data.
------------------------------
Code: 11010102
Display: Program 0002
Program NG 0002
Used by: GL2,GL541,IP1,QP242,QP201,QP202,QP203
Cause: There is not a mark read sequence at the mark number set in the mount sequences (application
sequence, print sequence).
Remedy: Checking the data in MCS does not often produce results. It is thought that the data may be
changed in transmission. Therefore, check the data and transmit the program.
------------------------------
Code: 11010103
Display: Program 0010
Used by: GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,QP242,QP201,QP202,QP203
Cause: On the GL, the mark read sequence was not executed (or an error occurred) but the machine
attempted to execute the mount sequences (application sequence, print sequence).
Remedy: Move the mark read sequence in front of any mount sequences in the production program.
------------------------------
Code: 11010104
Display: Program X+
Used by: GL2,GL5,GL541,IP1,QP242,QP201,QP202,QP203
Cause: On the GSP, IP1 or GL, the target position set for the X axis in the production program is out of
range.
Remedy: Make the +X value in the production program's mark read sequence smaller.
------------------------------
Code: 11010105
Display: Program X-
Used by: GL2,GL5,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -X direction set in the production program is out of range.
Remedy: Make the -X value in the production program (mark read sequence) larger.
------------------------------
Code: 11010106
Display: Program Y+
Used by: GL2,GL5,GL541,IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +Y direction set in the production program is out of range.
Remedy: Make the +Y value set in the production program (mark read sequence) smaller.
------------------------------
Code: 11010107
Display: Program Y-
Used by: GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -Y direction set in the production program is out of range.
Remedy: Make the -Y value set in the production program (mark read sequence) larger.
------------------------------
第 2 页
Code: 11010108
Display: Program SX+
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +SX direction set in the production program is out of range.
Remedy: Make the +SX value set in the production program (mark read sequence) smaller.
------------------------------
Code: 11010109
Display: Program SX-
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -SX direction set in the production program is out of range.
Remedy: Make the -SX value set in the production program (mark read sequence) larger.
------------------------------
Code: 1101010A
Display: Program SY+
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the +SY direction set in the production program is out of range.
Remedy: Make the +SY value set in the production program (mark read sequence) smaller.
------------------------------
Code: 1101010B
Display: Program SY-
Used by: IP1,QP242,QP201,QP202,QP203
Cause: The target value in the -SY direction set in the production program is out of range.
Remedy: Make the -SY value set in the production program (mark read sequence) larger.
------------------------------
Code: 1101010C
Display: Program S+
Used by: QP242,QP201,QP202,QP203
Cause: The print sequence set in the production program is out of range in the +X direction.
Remedy: Make the +X value set in the print sequence of the production program smaller.
------------------------------
Code: 1101010D
Display: Program S-
Used by: QP242,QP201,QP202,QP203
Cause: The print sequence set in the production program is out of range in the -X direction.
Remedy: Make the -X value set in the print sequence of the production program larger.
------------------------------
Code: 1101010E
Display: Program 0001
Used by: GL2,QP242,QP201,QP202,QP203
Cause: The head number has not been entered in sequence data.
Remedy: Check the "H" heading in the production program.
------------------------------
Code: 1101010F
Display: Program 0020
Used by: GL2,GL541,QP242,QP201,QP202,QP203
Cause: G data is not entered in the application sequence.
Remedy: Correct the data in MCS and transmit the program.
------------------------------
Code: 11010110
Display:
Used by: QP242,QP201,QP202,QP203