advance pickup number via the numerical input pad. If this is not entered, the tray will be unloaded again. See the IP1 manual for more details. ------------------------------ Code: 12044002 Display: Please check carrier…
Code: 12042004
Display: Tape Feeder 18ST
Used by: CP5
Cause: An improperly positioned feeder activated the tape leaf sensor at station 18.
Remedy: Check the position of the feeders around the tape leaf sensor. If there are any problems,
reposition the feeders.
------------------------------
Code: 12042005
Display: MFU feeder interference error
Used by: QP3
Cause: MFU area sensor is being triggered by the feeder.
Feeder cannot be used due to possible contact problem with the machine.
Remedy: Replace the feeders.
------------------------------
Code: 12042007
Display: Test area remaining capacity warning
Used by: QP3
Cause: Test area capacity has almost been exhausted.
Wipe off the glue dots in the test area.
Execute the test area [Clear] command to set to the initial dispensing point position.
Remedy: Wipe off the glue dots in the test area.
Execute the test area [Clear] command.
------------------------------
Code: 12042008
Display: Test area full
Used by: QP3
Cause: Test area remaining capacity setting has been reached.
Wipe off the glue dots in the test area.
Remedy: Press Ready ON to set dispensing to the initial position.
------------------------------
Code: 12042009
Display: Test area setting error
Used by: QP3
Cause: There is mistake in a test area setting being used.
Check the slot number.
Parameter Item name that should be checked.
Remedy: Check the item .
------------------------------
Code: 1204200A
Display: Test area setting change
Used by: QP3
Cause: Dispensing point in test area has been set to the initial position due to change in test area
setting.
Remedy: Wipe off glue dots in the test area before carrying out operation.
------------------------------
Code: 12044001
Display: Tray eject error
Used by: IP1,IP2
Cause: When the tray was to be unloaded, the tray unloading sensor was not on.
Remedy: If the tray was not unloaded, remove the tray by hand. If the tray was unloaded, check the tray
coordinates set in Part data and adjust the sensor. If this error occurs on the IP1, always enter the
第 477 页
advance pickup number via the numerical input pad. If this is not entered, the tray will be unloaded
again. See the IP1 manual for more details.
------------------------------
Code: 12044002
Display: Please check carrier
Used by: IP1
Cause: The subrobot has set the part on the carrier, but the part detection sensor is not on. Alternately,
the sensor is on even if there are no parts (IP).
Remedy: Remove parts from the carrier. Check and adjust the sensor. If these parts are not removed
they will be considered to be defective and therefore rejected when the start button is pressed. These
parts are considered to be defective for reasons such as when the sequence number has been changed
through the command functions, if a first pin check error occurs, if the program has been changed.
------------------------------
Code: 12044003
Display: "Sub nozzle parts set error" (IP)
Used by: IP1
Cause: The subrobot nozzle's component check sensor is still reading on even though the subrobot
should already have placed the component on the subrobot.
Remedy: If subrobot nozzle is not holding a component, adjust the subrobot nozzle's vacuum (component
check) sensor. If the subrobot nozzle is holding a component, the subrobot chuck vacuum braking
pressure may be low. Make sure that the tube is not clogged or punctured.
------------------------------
Code: 12044004
Display: "CHECK REMOVE_CHECK SENSOR" (IP)
Used by: IP1
Cause: The tray removal sensor (IN3-24 REMOVE_CHECK) has been tripped before the tray was
removed.
Remedy: Remove the object that is triggering the sensor, or adjust the sensor beam alignment.
------------------------------
Code: 12044101
Display: XY-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the XY-axis during the un/docking of the remover.
Remedy: Check for interference with the XY-axis.
------------------------------
Code: 12044102
Display: Z-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the Z-axis during the un/docking of the remover.
Remedy: Check for displacement between the robot and the lifter.
------------------------------
Code: 12044103
Display: Z-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the Z-axis during the un/docking preparation of the remover.
Remedy: Check for displacement between the robot and the lifter.
------------------------------
Code: 12044104
Display: Z-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred during retraction of the Z-axis.
第 478 页
Remedy: Check for interference with the Z-axis.
------------------------------
Code: 12044105
Display: XY-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the Y-axis during movement to the empty-tray pick-up position.
Remedy: Check for interference with the Y-axis.
------------------------------
Code: 12044106
Display: Z-axis travel error!
Used by: NP2,QP3
Cause: A travel error occurred for the Z-axis during movement to the empty-tray pick-up position.
Remedy: Check for interference with the Z-axis.
------------------------------
Code: 12046001
Display: Plt ID Battery Check
Used by:
Cause: There is no response from the ID card on the UP lifter.
Remedy: Replace the ID card battery, or the ID card itself.
------------------------------
Code: 12046002
Display: Pallet ID Read Error
Used by: CP5
Cause: The ID on the pallet on the UP lifter could not be read.
Remedy: Check that the ID reading location has not moved. Alternately, replace the ID card.
------------------------------
Code: 12046003
Display:
Used by:
Cause: Next pallet changeover could not be performed.
Remedy: Check the next pallet or re-supply the parts.
------------------------------
Code: 1204A001
Display: VF Comp Er (*) D No. ***
Used by:
Cause: The measurement results are too small.
Remedy: Check whether the part has been set correctly. Alternately, the part is defective.
------------------------------
Code: 1204A002
Display: VF Comp Er (*) D No. ***
Used by:
Cause: The measurement results are too large.
Remedy: Check whether the part has been set correctly. Alternately, the part is defective.
------------------------------
Code: 1204A003
Display: VF Comp Er (*) D No. ***
Used by: CP3
Cause: The measurement results are out of range.
Remedy: Check whether the part has been set correctly. Alternately, the part is defective.
------------------------------
Code: 1204A101