Display: Used by: Cause: The part external shape could not be detected. Remedy: Check that the vision processing system is taking the image correctly. ------------------------------ Code: 1D104044 Display: 1D104044 Used …
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0FD080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D0FE???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0FF???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D100002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D104006
Display:
Used by:
Cause: The part is tilted too much.
Remedy: Check the way the part is picked. Check the image taken by vision processing.
------------------------------
Code: 1D104041
Display:
Used by:
Cause: The image is not set (the nozzle is dirty or there is foreign matter on the parts), the part is mis-
shaped (the edges are uneven), and there is a large discrepancy between the part and the values set in
Part data.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D104042
Display:
Used by:
Cause: The part could not be found.
Remedy: Check Part data and check that the part is being picked properly.
------------------------------
Code: 1D104043
第 1405 页
Display:
Used by:
Cause: The part external shape could not be detected.
Remedy: Check that the vision processing system is taking the image correctly.
------------------------------
Code: 1D104044
Display: 1D104044
Used by:
Cause: The part size exceeds the tolerance range.
Remedy: Check the shape of the part and the supply direction.
------------------------------
Code: 1D104045
Display:
Used by:
Cause: The tilt of the part exceeds 15 deg. The four areas are not uniform in tilt.
Remedy: Check that the part is being picked correctly, and check the part shape.
------------------------------
Code: 1D108002
Display:
Used by:
Cause: The part could not be picked. The nozzle used with this part is too large. Vision processing could
not detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D108100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D108110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D108111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D108112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D108113
Display:
第 1406 页
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D108114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D108115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D108120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D108121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D108122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D108123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D1082??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1083??
Display:
Used by:
Cause: The body is too short in the X direction.