FUJI错误代码查询.pdf - 第241页
the [Update] command. ------------------------------ Code: 11100701 Display: File-open error! Used by: NP2,QP3 Cause: Failed to open the nozzle settings file. All nozzle settings have been cleared. Remedy: Download an un…
------------------------------
Code: 11100508
Display: Nozzle memory file error
Used by: NP2,QP3
Cause: A nozzle memory file error occurred. All nozzle memory data has been cleared.
Remedy: Use the nozzle memory change command to re-register the nozzles.
------------------------------
Code: 11100601
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle specifications file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100602
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle specifications file.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100603
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle specifications file. All nozzle settings have been
cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100604
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle data items displayed in the parameter section are outside the prescribed range. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100605
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle specifications file. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100606
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle data for this machine are not included in the nozzle data file. All nozzle settings have been
cleared.
Remedy: Download compatible nozzle specification files, reboot the machine and load the settings using
第 240 页
the [Update] command.
------------------------------
Code: 11100701
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the nozzle settings file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100702
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle settings file.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100703
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle settings file. All nozzle settings have been
cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100704
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle data items displayed in the parameter section are outside the prescribed range. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100705
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle settings file. All nozzle
settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100706
Display: Nozzle name inconsistency error!
Used by: NP2,QP3
Cause: The nozzle spec. names displayed in the parameter section are not listed in the nozzle
specifications file.
Remedy: Download a correct nozzle settings file, reboot the machine and load the settings using the
[Update] command.
------------------------------
Code: 11100707
Display: Insufficient data!
Used by: NP2,QP3
第 241 页
Cause: Nozzle settings for this machine are not included in the nozzle settings file. All nozzle settings
have been cleared.
Remedy: Download a compatible nozzle settings file, reboot the machine and load the settings using the
[Update] command.
------------------------------
Code: 11100801
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle station settings file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle settings file, reboot the machine and load the settings using
the [Update] command.
------------------------------
Code: 11100802
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle station settings file.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100803
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle station settings file. All nozzle settings have
been cleared.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100804
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle station settings file. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100805
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle station settings for this machine are not included in the nozzle station settings file. All
nozzle settings have been cleared.
Remedy: Download a compatible nozzle station settings file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100901
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle station specifications file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle station specifications file, reboot the machine and load the
settings using the [Update] command.
------------------------------
Code: 11100902
第 242 页